_ DEC-O-LOG for 62XMX _ DOL, 62XMX-F001, System MAY 89 PROBLEM: 62XMX-F001 - Replace cable assembly, 17-01567-01, on 6200 systems in European countries which must comply with VDE federal environmental regulations 523/1969 and 1046/1984. FIELD EFFECTIVITY: This FCO applies to 6200 systems in European countries only. QUICK CHECK: Check for two ferrite beads on the 17-01567-01 cable, Rev C1, which connects J5 at the XTC module to the console terminal's bulkhead at the rear of the system. FCO KIT ORDERING: EQ-01543-01 FA-04849-01 _ DOL, 62XMX-F002, TBK50 Controller Problem, OCT 89 62XX VAX Systems PROBLEM: An incompatibility situation can occur with TK50 tapes. The problem is caused by the TBK50 controller (T1034) using a different soft error (i.e., bad spot recovery) routine than used by TQK50, TUK50, TZK50, TQK70 and TBK70 (T1035) controllers. FIELD EFFECTIVITY: This FCO should be installed on 6000-2XX (62XX) systems that use the TK50 for making tapes that will be read on another system type (i.e., MicroVAX, VX2000, 11/785, etc.). This FCO changes the revision of the T1034 module to K3, K4 or K5. It does not change the rev. of the 6000-2XX systems. QUICK CHECK: The revision of the T1034 should be K3, K4 or K5. FCO KIT ORDERING: EQ-01552-02 FCO, Parts FA-04857-03 FA Document **European version also available _ DOL, 62XMX-I003, VAX 6000-2XX Systems, Jan 92 62XMX-I003 JAN 92 - PROBLEM: Installation of the DWMVA option requires 6000-2XX CPU modules to be upgraded to a new minimum part revision of "AL" or higher. FIELD EFFECTIVITY: Upgrade applicable 6000-2XX system CPU modules (T2011-00) to a minimum revision "AL" ONLY WHEN ADDING A DWMVA option to an existing system. Also, ensure a spare module rev. "AL" is available to support this at the SDU. This FCO incorporates ECO #T2011-TW010. SOLUTION: Upgrade applicable 6000-2XX system Cpu modules upon installation of the DWMVA add-on option. Use minimum part revision "AL" or higher. QUICK CHECK: For module rev. "AL" ROM location E16 should be marked 23-303E9-00 and ROM location E8 should be p/n 23-302E9-00. The DEC on-site labor charge will be the time required to install and test the FCO at the then current hourly rate. FCO KIT ORDERING EQ-01630-01 T2011-00 Module Minimum Rev. "AL" FA-04965-01 FCO Document