_ DEC-O-LOG for 882BA _ DOL, 882BA-R001, CPU JUN 87 PROBLEM: F1001-LK005 - New Part Revision "D2/D3". A problem on the MCL module with updating the "Error Page Address" may not allow the operating system to successfully call out the correct array when encountering a memory error. F1001-LK006 - New Part Revision "E2/E3". Introducing new version MCA 19-22619-01. Performance Enhancement. F1001-LK008 - New Part Revision "F4". No longer using part 19-22579-01 (National 8480). Replacing with Part 19-22579-02 (National 8480A). F1001-LK009 - New Part Revision "F3". No longer using Part 19-22579-01 (National 8480). Replacing with part 19-22579-02 (National 8480A) FIELD EFFECTIVITY: Retrofit all VAX 8800 systems to Revision Level "B1". This FCO incorporates the following ECOs: F1001-LK005, F1001-LK006, F1001-LK008, F1001-LK009. QUICK CHECK: Jumper configuration (W1-out, W2-in, W3-out, W4-in) FCO KIT ORDERING: EQ-01450-01 FCO, PARTS FA-04736-02 FCO only _ DOL, 882BA-R002, F1005 - F1010, May 87 PROBLEM: F1005: Address bit 23, when used, causes cache miss problems. The workaround was to generate a memconfig.dat file with "holes" causing addresses with bit 23 used not to be cached. Console Rev D requires this FCO. F1010: Only fixes power fail problems which can cause VMS to crash. FIELD EFFECTIVITY: Retrofit all VAX 8800 systems to Revision Level "C1". The KA88-AA Rev also changes to "C1" with these ECOs installed. QUICK CHECK: F1005: E90 contains 9-22596-00, F1010: W1 in, W2 out, W3 out, W4 out This revised FCO supersedes Revision A, released 17 April 1987. It has been revised to change the "LOU" from "I" to "R". FCO KIT ORDERING: EQ-01448-01 FCO, PARTS EQ-01448-02 FCO, PARTS FA-04734-01 FCO only _ DOL, 882BA-R003, F1005 - F1010 JUL 87 PROBLEM: 1. Remote port fix to correct loss of characters and "Disable Local Console" command. 2. The commands I, U, and START cannot be initiated unless the machine is halted. 3. The entire word TEST must be typed to invoke micro diagnostics. 4. System may crash when the PRO is powered off. This fix needs Console Rev "22E and VMS V4.6. 5. The NBIB may log a "Read Retry Timeout" error when two other devices capable of Interlock instructions are on the same BI. This problem is fixed with a change to the CPU microcode. FIELD EFFECTIVITY: Retrofit all VAX 8800 systems to Revision Level "D1". This FCO incorporates the following ECO: BT-ZMAAD-C3-LK002 - (New Part Rev. V22E). QUICK CHECK: Console will show V5.0. FCO KIT ORDERING: FA-04779-02 FCO only _ DOL, 882BA-I004, F1011 Module FEB 88 PROBLEM: Unibus time out errors caused by SMP (Symmetric Multi-Processing feature of VMS V5.0. FIELD EFFECTIVITY: Retrofit all VAX 8800 systems to Rev. level "E1". This brings the DB88 to Rev. level "C1". QUICK CHECK: Check E67 for part number 19-22633-03 and part number 19-22631-06 in E128. FCO KIT ORDERING: EQ-01502-01 FCO, PARTS FA-04797-01 FCO only _ DOL, 882BA-I005, CPU, NOV 88 PROBLEM: PC38N has a number of problems which can cause systems to crash, and the Console to "Hang" or crash. A detailed problem list can be obtained through Console Release Notes:RELEASE.32. FIELD EFFECTIVITY: This FCO should be installed on all VAX 8800/8820/ Configuration N systems. It will change the revision of the VAX 8800/8820 Configuration N systems to "E1". QUICK CHECK: When the system is booted, it will automatically print the console microcode revision on the screen. It should be V8.0. This revised FCO supersedes Rev. A released on 27 July 1988. It has been revised to correct steps 1 through 4 located on pages 10 and 11. FCO KIT ORDERING: EQ-01523-01 FCO, PARTS FA-04817-01 FCO only _ DOL, 882BA-I006, CPU JUL 88 PROBLEM: The current MCL (F1001) can only isolate down to the failing mother board. This fixes the problem of the 64 meg memory arrays not always being able to isolate a problem down to the failing FRU (daughter board) when the failure is intermittent memory problems. FIELD EFFECTIVITY: This FCO will upgrade systems that contain MS88-DAs only on VAX 8800/8820 Configuration N. QUICK CHECK: Look form F1021 MCL module. FCO KIT ORDERING: EQ-01518-01 FCO, PARTS FA-04820-01 FCO only _ DOL, 882BA-F007, 8800/8810 Conf N Systems, Rev C, MAY 90 PROBLEM: This FCO corrects the reliability of the system recovering from "brownouts". It also provides multiple corrections to the PRO Console Code; see Console Release Notes for further details. FIELD EFFECTIVITY: This FCO should be installed on all VAX 8800/8820 Conf. N systems. It will change the revision of the above systems to "F1". The revision of PC37N will change to "N03". This revised FCO supersedes Revision B, released 19 March 1990. It was revised to correct the microcode required. QUICK CHECK: When the system is booted, it will automatically print the console microcode revision on the screen. It should be V9.3. FCO KIT ORDERING: EQ-(N/A) FA-04858-03 FCO Document