_ FCO 9XXX-S014, 280 DC Wiring diagram error, potential safety hazard ______________________________________________________________________________ | DIGITAL FCO CATEGORY PAGE 1 | | [S] OF 4 | |______________________________________________________________________________| | FIELD CHANGE ORDER NUMBER: 9XXX-S014 | |______________________________________________________________________________| | APPLICABILITY: This "S" coded FCO will be installed on all VAX 9000 systems.| |______________________________________________________________________________| | PROBLEM & SYMPTOM: On the 9000-210,110 systems, the silkscreen on PIP cover | | is incorrect. The 280 DC wiring is a potential safety hazard because of the | | incorrect wiring diagram. Also on the 9000-210,110 there is no fuse label for| | the PIP, as there is for the 9000-4XX,3XX. With no fuse labels there is the | | potential that incorrect fuses may be used on the 9000-210,110. | | (Continued on Page 2) | |______________________________________________________________________________| | SOLUTION: The PIP cover decal will go over the existing silkscreen along | | with the PIP fuse label. All interconnect labels will go on the back door | | of their specific cabinet. The 36-36578-01,02 will be added below the | | components (power disconnect switch and power present lights). Currently, | | the nomenclature is present above these components but is blocked by bustle. | |______________________________________________________________________________| | QUICK CHECK: There is no Quick Check, these are new labels and no systems | | will have them. | |______________________________________________________________________________| | PRE/COREQUISITE FCO: | MTTI HRS | | N/A | 1 hr | |___________________________________________________________________|__________| | TOOL/TEST EQUIPMENT: | | N/A | |______________________________________________________________________________| | FCO PARTS INFORMATION | |______________________________________________________________________________| | FCO KIT NO. | DESCRIPTION OF CONTENTS | EQ KIT VARIATION | |______________|____________________________________________| APPLICABILITY | |EQ-01640-0* | See Page 2 for description | | |FA-04976-01 | FCO Document | | |______________|____________________________________________|__________________| | FCO CHARGING INFORMATION | |______________________________________________________________________________| | WARRANTY/CONTRACT || NONWARRANTY/NONCONTRACT | |___________________________||_________________________________________________| | ON-SITE | OFF-SITE || ON-SITE | OFF-SITE | MATERIAL ONLY | |_____________|_____________||_____________|_____________|_____________________| |TRAVEL/| EQ | | EQ ||TRAVEL/| EQ | | EQ |ORDER-ADMIN,HANDLING | |INSTALL| KIT |INSTALL| KIT ||INSTALL| KIT |INSTALL| KIT |PKG,SHIPPING & EQ KIT| |_______|_____|_______|_____||_______|_____|_______|_____|_____________________| | DEC | DEC | DEC | DEC || DEC | DEC | DEC | DEC | DEC | |_______|_____|_______|_____||_______|_____|_______|_____|_____________________| | APPROVALS | |______________________________________________________________________________| | SPE | DSHQ LOGISTICS | DS PRODUCT SAFETY | | Alice Jacobson | Dick Joseph | Robert Brister | |___________________|____________________________|_____________________________| | SPE MANAGER |This document is published | | | Dino Genova |on multiple media including | | |___________________|Customer Services and MDS |_____________________________| | MICROMEDIA |Microfiche Libraries. It is| FCO REVISION | | Diane MacDonald |also available electronic- | A | |___________________|all via the SSD CD-ROM and |_____________________________| | POPULATION |TIMA. | PARTS AVAILABILITY | | 419 | | | |___________________|____________________________|_____________________________| _ _ _ _ _ _ _ | FCO 9XXX-S014 | | | | | | | | | |d|i|g|i|t|a|l| | PAGE 2 OF 4 |_|_|_|_|_|_|_| | | _______________________________|_________________________________________ Problem/Symptom (Continued) The interconnect diagram labels are now available and should be installed to ensure proper recabling when cables are unplugged. The 36-36578-01, 02 is required because the bustle obscures nomenclature identifying power disconnect and power present lights on the bulkhead. FCO Part Information (Continued) VAX 9000-110 and 210 -------------------- EQ KIT NUMBER CONTENTS ------------- ---------------------------------------------- EQ-01640-01 EA CAB LABEL NAME PART NUMBER LOCATION -- --- ---------- ----------- -------- 1 ea IOA PIP FA-04973-01 PIP decal 1 ea IOA PIP FUSE FA-04973-02 cover pip 1 ea IOA SIGNAL DIAGRAM 36-36498-03 back 1 ea CPA SIGNAL DIAGRAM 36-36498-02 back door 1 ea SCU SIGNAL DIAGRAM 36-36498-01 back door VAX 9000-310/320/330/340, and 410/420/430/440 --------------------------------------------- EQ-01640-02 EA CAB LABEL NAME PART NUMBER LOCATION -- --- ---------- ----------- -------- 1 ea IOA INTERCONNECT 36-36501-01 back, door 1 ea IOA DC INTERCONNECT 36-36501-02 back, door 1 ea SCU INTERCONNECT 36-36499-01 back, door 1 ea SCU DC INTERCONNECT 36-36499-02 back, door 1 ea CPA INTERCONNECT 36-36500-01 back, door 1 ea CPA DC INTERCONNECT 36-36500-02 back, door 1 ea IOA DC POWER PRESENT/ POWER DISCONNECT 36-36578-01 bulkhead, rear 1 ea IOA DC POWER PRESENT 36-36578-02 bulkhead, rear VAX 9000-330/340 and 430/440 (only) ----------------------------------- EQ-01640-03 EA CAB LABEL NAME PART NUMBER LOCATION -- --- ---------- ----------- -------- 1 ea IOB INTERCONNECT 36-36501-03 back, door 1 ea IOB DC INTERCONNECT 36-36501-04 back, door 1 ea CPB INTERCONNECT 36-36500-04 back, door 1 ea CPB DC INTERCONNECT 36-36500-03 back, door TABLE OF CONTENTS PAGE ----------------- ---- Label Installation Procedure - 9000-110, 210........................ 3 Labels #36-36498-01,02,03, (EQ-01640-02)............................ 3 Label Inst. Procedure - 9000-310, 320, 330, 340, 410, 420, 430, 440. 3 Installation Procedure - VAX 9000-330, 340, 430, 440 (only)......... 4 LARS Form........................................................... 4 _ _ _ _ _ _ _ | FCO 9XXX-S014 | | | | | | | | | |d|i|g|i|t|a|l| | PAGE 3 OF 4 |_|_|_|_|_|_|_| | | _______________________________|_________________________________________ Label Installation Procedure - 9000-110, 210 -------------------------------------------- 1. Shut down and lock out the system from the ac power source. 2. From the rear of the cabinet, using the Phillips screwdriver, release the four screws that secure the panel cover to the PIP assembly. 3. Carefully remove cover. 4. Place FA-04973-01 (EQ-01640-02) over the existing silkscreen label. Put FA-04973-02 (EQ-01640-02) below it. 5. Replace cover. 6. Remove locks and tags, and bring power up. Labels #36-36498-01, 02, 03, (EQ-01640-02) ------------------------------------------ Note: System does not need to be shut down to install these labels. 7. Place 36-36498-01 (EQ-01640-02) on back door of SCU cabinet (70-26888-01). 8. Place 36-36498-02 (EQ-01640-02) on back door of CPU cabinet (70-26890-01). 9. Place 36-36498-03 (EQ-01640-02) on back door of IO cabinet (70-25855-01). 10. Report this FCO activity on the LARS form in the "Fail Area/ Module/FCO/Comments" column as follows: FCO 9XXX-S014 (See Page 4). Label Inst. Procedure - 9000-310, 320, 330, 340, 410, 420. 430, 440 ------------------------------------------------------------------- Note: System does not need to be shut down to install these labels. 1. Place 36-36499-01,02 (EQ-01640-03) on back door of SCU cabinet (70-27520-01). 2. Place 36-36500-01,02 (EQ-01640-03) on back door of CPU cabinet (70-27518-01). 3. Place 36-36501-01,02 (EQ-01640-03) on back door of IO cabinet (70-27918-01). 4. Place 36-36578-01 (EQ-01640-03) below the power disconnect switch on the IO cabinet (70-27918-01). _ _ _ _ _ _ _ | FCO 9XXX-S014 | | | | | | | | | |d|i|g|i|t|a|l| | PAGE 4 OF 4 |_|_|_|_|_|_|_| | | _______________________________|_________________________________________ 5. Place 36-36578-02 (EQ-01640-03) below the power present lights on the IO cabinet (70-27918-01). 6. If system is a VAX 9000-310 or 320, report this FCO activity on the LARS form in the "Fail Area/ Module/FCO/Comments" column as follows: FCO 9XXX-S014 Installation Procedure - VAX 9000-330, 340, 430, 440 (only) ----------------------------------------------------------- System does need to be shut down to install these labels. 1. Place 36-36500-03,04 (EQ-01640-01) on back door of 2nd CPU cabinet (70-27528-01). 2. Place 36-36501-03,04 (EQ-01640-01) on back door of 2nd IO cabinet (70-27918-02). 3. Report this FCO activity on the LARS form in the "Fail Area/ Module/FCO/Comments" column as follows: FCO 9XXX-S014 LARS CATEGORY S USA GIA EUROPE Activity - (a)Contract and Warranty W U Y (b)IN-DEC Contract K U Hardware Segment Code 111 111 Non Contract/Non Warranty F F F (c)RTD/Off-site Agreement F U Product Line 031 DEC Option 9XXX 9XXX 9XXX Type of Call M M M Action Taken D D I Fail Area-Module-FCO-Comments 9XXX-S014 9XXX-S014 9XXX-S014 Material Used EQ-01640-0* EQ-01640-0* EQ-01640-0* (a) Warranty Optimum, Warranty Standard and Warranty Basic (on-site) Agreements; * Note material (only) free of charge for all customers. (b) Applies to IN-DEC Area Only (c) RTD=Return to Digital or Off-site Agreements; If Field Engineer On-site, use Activity Code "F". \\FCO_DOCS \\9XXX \\9000 \^ 9XXX