_ DEC-O-LOG for BC40A _ DOL, BC40A-M0006, Cable Assy fails, JAN 84 PROBLEM: Nova (vendor) cable assembly fails on high voltage with the standard test. Product Safety Case #801541. CORRECTION: Replace the BC40A, L cables (17-00082-00, 01) made by the NOVA with the (17-0082-00, 01) cables made by the vendor, APGJ. IN-PLANT EFFECTIVITY: Nov 83 FIELD EFFECTIVITY: Retrofit all BC40A and BC40L cables made by the "NOVA" on the H332 Chassis with the "APGJ" Cables. Dispose of the Cables by cutting the old Cables in half. The Cables (NOVA) may not conform to the Purchase Specs "High Voltage Withstand" PS-17-00082-00. QUICK CHECK: The back of the connector should be "APGJ" not "F" (F is on the NOVA Cables). The DEC on-site labor charge will be the time required to install and test the FCO at the then current hourly rate. FCO KIT ORDERING: EQ-01067-00: FCO, PARTS FA-04286-00: FCO only