_ K-RM-CI780-A-0 Rev E, CI780 Revision Matrix, Sep 1990 __________________________________________________________________________________________________________________________________ | OPTION NAME | REVISION HISTORY OF | | CI780-AA, -AB, -MA | VAX SBI TO COMPUTER INTERCONNECT ADAPTER (CI780) | |--------------------------------------------------------------------------------------------------------------------------------| | | FUNCTIONAL HISTORY OF CHANGES WITH EACH PASS | |____RM_ECO_#__________| | | CI780-TW010 | This ECO updates documentation to accurately list current minimum part revisions used in the | | | ci780. | | | | | CI780-MK005 | This ECO updates documentation relative to the introduction of the l0118. | | | | | | | | CI780-MK004 | Initial Release of the Revision Matrix for all variations of the CI780. | | | | | | THE UNIT REVISION CONTROL CHANGES IN THIS DOCUMENT WILL BE CONTROLLED BY THE REVISION MATRIX | | | STANDARD EL-00068-00. | | | | | | IN RELEASE OF THIS DOCUMENT, ALL CONSTRUCTIVE COMMENTS MUST MUST BE WRITTEN UP AND SUMITTED TO ONE | | | OF THE FOLLOWING: | | | | | | PRIMARY CONTACTS: | | | | | | SASE VAXCLUSTER ENGINEERING MRO1 | | | MIDRANGE CSSE VWO | | | MANUFACTURING BTO | | | | | | ALL REVISIONS INDICATED ARE THE LATEST AVAILABLE REVISIONS . | | | | | | | | | | | | | | | | | | | |______________________|_________________________________________________________________________________________________________| | | | | | | | | | | | | THIS DRAWING AND THE SPECIFICATIONS CONTAINED |DRN: A.HAYNES |DATE: | d | i | g | i | t | a | l | | HEREIN ARE CONFIDENTIAL AND PROPRIETARY. THEY |___________________________|_________________|_____|___|___|___|___|___|______| | ARE THE PROPERTY OF DIGITAL EQUIPMENT | | | TITLE | | CORPORATION AND SHALL NOT BE REPRODUCED OR |CHK'D: F.CARBONE |DATE: | CI780 | | COPIED OR USED IN WHOLE OR IN PART AS THE |___________________________|_________________| REVISION MANAGEMENT DOCUMENT | | BASIS FOR THE MANUFACTURE OR SALE OF ITEMS | | |________________________________| | WITHOUT WRITTEN PERMISSION. THIS IS AN |RESP.ENG.: B.MCKINSTRY |DATE: |SHEET 1 OF 12 | | UNPUBLISHED WORK PROTECTED UNDER THE FEDERAL |___________________________|_________________|________________________________| | COPYRIGHT LAWS. _____________________________ | | | FILENAME: CI780AD.RMF | | Revision Matrix |MFG.ENG.: C.HEANEY |DATE: | DOCUMENT NUMBER | | (History) |___________________________|_________________|________________________________| | |FIELD | |SIZE|CODE| NUMBER | REV | | |SERVICE: D.HARRIGNTON |DATE: | K | RM | CI780-A-0 | E | |_________________________________________________|___________________________|_________________|____|____|________________|_____| ____________________________________________________________________________________________________________________________________ | OPTION NAME | REVISION HISTORY OF | | CI780-AA, -AB, -MA | VAX SBI TO COMPUTER INTERCONNECT ADAPTER (CI780) | |----------------------------------------------------------------------------------------------------------------------------------| | | | TABLE OF CONTENTS | | ----------------- | | | | SECTION | | | | 1.0 INTRODUCTION.....................................3 | | 1.1 HOW TO READ REV MATRICES.........................3 | | | | 2.0 CI780-AA/AB/SA/SB/MA | | 2.1 HISTORY REVISION.................................5 | | 2.7 MATRICES.........................................11 | | | | 3.0 CI780-MA | | 3.1 HISTORY REVISION.................................7 | | 3.4 MATRICES.........................................9 | | | | | | | | | | | | CI780 UNIT VARIATIONS | | | | VAR | TITLE | | ----------------|--------------------------------------------------------------- | | CI780-AA | 11780 CI PORT TO STAR COUPLER, 120V | | CI780-AB | 11780 CI PORT TO STAR COUPLER, 240V | | CI780-MA | CI780 MODULE SET, NO BACKPLANE, NO POWER | | CI780-SA | DUAL CI780 STARTER KIT: 2 CI780-AA, SC008-AC, 2 BNCIA-10, 120V | | CI780-SB | DUAL CI780 STARTER KIT: 2 CI780-AA, SC008-AC, 2 BNCIA-10, 240V | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | |__________________________________________________________________________________________________________________________________| | | | | | | | |TITLE | | DOCUMENT NUMBER | | | | | | | | | | |________________________________| | d | i | g | i | t | a | l | CI780 | Sheet 2 of 12 |SIZE|CODE| NUMBER | REV | | | | | | | | | REVISION MANAGEMENT DOCUMENT | | K | RM | CI780-A-0 | E | |___|___|___|___|___|___|___|____________________________________________________|________________|____|____|________________|_____| ____________________________________________________________________________________________________________________________________ | OPTION NAME | REVISION HISTORY OF | | CI780-AA, -AB, -MA | VAX SBI TO COMPUTER INTERCONNECT ADAPTER (CI780) | |----------------------------------------------------------------------------------------------------------------------------------| | 1.0 | | INTRODUCTION | | ------------ | | | | THE PURPOSE OF THIS DOCUMENT IS TO DEFINE THE COMPATIBLE REVISION LEVELS OF THE CI780. REVISION LEVELS ARE TRACKED ACCORDING | | TO DEC STANDARD 068. | | | | A TEAM COMPOSED OF ENGINEERING, MANUFACTURING AND CUSTOMER SERVICE WILL REVIEW ALL CHANGES AND DETERMINE WHEN THE REVISIONS | | IN THIS DOCUMENT WILL BE CHANGED. THIS DOCUMENT IS UNDER ECO CONTROL AND WILL BE UPDATED BY ENGINEERING VIA THE NORMAL ECO | | PROCESS. | | | | THIS RM DOCUMENT CAN BE OBTAINED IN THE FOLLOWING MANNER: | | | | (1) ORDER FROM ENGINEERING DESIGN SERVICES BY P/N K-RM-CI780-A-0 | | (2) VAX LIBRARY MICROFICHE | | (3) ENET - COPY VOLKS::CLUSTER$REV:CI780_REV.DOC | | (LATEST VERSION ALWAYS AVAILABLE) | | | | THIS DOCUMENT WILL BE UPDATED WHEN AN ECO IS GENERATED TO A PART THAT CAUSES THE REVISION OF THE UNIT AND/OR COMBINATION | | OF UNITS TO CHANGE. | | | | ALL REVISIONS NOTED IN THIS DOCUMENT ARE MINIMUM REVISIONS. HIGHER REVISIONS ARE COMPATIBLE UNLESS OTHERWISE NOTED | | | | PART REVISIONS ARE TRACKED ACCORDING TO DEC STANDARD 012 CONVENTIONS. EACH PART HAS AN ALPHANUMERIC REVISION, UP TO A MAXIMUM | | OF 4 DIGITS. WHEN A PART REVISION CHANGES, THE ALPHA CHARACTER, NUMERIC OR BOTH MAY CHANGE: IF THE ALPHA CHARACTER CHANGES | | THE NEW PART IS COMPATIBLE WITH AND CAN REPLACE EARLIER REVISIONS - A "C1" CAN REPLACE AN "A1" AND A "B1"; IF THE NUMERIC | | ONLY CHANGES, THE NEW PART IS INTERCHANGEABLE AND BACKWARDS COMPATIBLE - D1, D2, AND D3 ARE INTERCHANGEABLE AND CAN REPLACE | | EARLIER REVISIONS. | | | | | | | | 1.1 | | HOW TO READ REV MATRICES | | ------------------------ | | | | THESE REVISION HISTORY SECTIONS ARE BROKEN DOWN INTO TWO MAJOR SECTIONS: | | | | (1) DESCRIPTION OF CHANGES (HISTORY PAGE) | | | | THIS DESCRIBES WHAT PARTS/UNITS WERE CHANGED AND WHY. IT WILL CONTAIN THE FOLLOWING AT A MINIMUM: | | ECO #, PROBLEM CORRECTED, SYMPTOM, NEW PART REVISION, QUICK CHECK, FC0 # AND ANY OTHER COMMENTS THAT | | THE TEAM DECIDES IS NECESSARY. | | | | (2) MATRICES SHOWING REVISION COMPATIBILITIES. | | | | THESE MATRICES LIST THE MINIMUM COMPATIBLE REVISIONS FOR EACH PART. HIGHER REVISIONS ARE ALSO COMPATIBLE | | UNLESS OTHERWISE NOTED. | | | | | |__________________________________________________________________________________________________________________________________| | | | | | | | |TITLE | | DOCUMENT NUMBER | | | | | | | | | | |________________________________| | d | i | g | i | t | a | l | CI780 | Sheet 3 of 12 |SIZE|CODE| NUMBER | REV | | | | | | | | | REVISION MANAGEMENT DOCUMENT | | K | RM | CI780-A-0 | E | |___|___|___|___|___|___|___|____________________________________________________|________________|____|____|________________|_____| ____________________________________________________________________________________________________________________________________ | OPTION NAME | REVISION HISTORY OF | | CI780-AA, -AB, -MA | VAX SBI TO COMPUTER INTERCONNECT ADAPTER (CI780) | |----------------------------------------------------------------------------------------------------------------------------------| | CI780-AA/AB REVISION K1 | | ----------------------- | | *CREATION DATE IS SEPT 1990. | | *THIS REVISION CHANGED THE CI780 FROM "J" TO "K" | | *THIS REVISION UPDATES THE DOCUMENT TO CORRECTLY LIST THE MINIMUM COMPATABLE PART REVISIONS OF THE CI780. | | *QUICK CHECK - VERIFY THE PRESENCE OF CI780-AA/AB OPTION REVISION K1. | | *DIAGNOSTIC RELEASE 28 (EVNDX 28). Contains the minimum usable diagnostics for the L0118 Module | | | | CI780-AA/AB REVISION J1 | | ----------------------- | | *CREATION DATE IS MAY 1988. | | *THIS REVISION CHANGED THE CI780 FROM "H" TO "J" | | *THIS REVISION DOCUMENTS THE INTRODUCTION OF THE L0118 IN PLACE OF THE L0100. | | *PROBLEM/CORRECTION - (N/A) | | *QUICK CHECK - VERIFY L0118 IS INSTALLED. | | *DIAGNOSTIC RELEASE 28 (EVNDX 28). Contains the minimum usable diagnostics for the L0118 Module | | | | CI780-AA/AB REVISION H1 | | ----------------------- | | THIS IS THE INITIAL INTRODUCTION OF THE REVISION MATRIX FOR CI780. | | | | *CREATION DATE IS JUNE 1987. | | *THIS REVISION CHANGED THE CI780 FROM "F" TO "H". | | *THIS REVISION CHANGE INVOLVED AN ECO TO THE L0100 MODULE BRINGING THE MODULE REV TO "E" | | *PROBLEM/CORRECTION | | L0100-MK006 1. ORIGINAL 140 MHZ CLOCK AND ASSOCIATED HARDWARE HAS TENDENCY TO DRIFT OFF FREQUENCY. | | 2. EXISTING WIRES CAUSED BY ECO #MK005 CAUSE EXTENSIVE MANUFACTURING COSTS. | | THE FOLLOWING CORRECTIONS ARE IMPLEMENTED BY THIS ECO: | | 1. CHANGE 140 MHZ CRYSTAL TO NEW HYBRID OSCILLATOR (PN 18-23940-01) AND DELETE UNNECESSARY HARDWARE. | | 2. PHASE IN NEW ETCH TO REMOVE WIRE'S ON MODULE. | | | | L0100-MK005 1. MAJOR PROBLEMS IN THE INTERFACE WHICH WOULD BE HIGHLY VISIBLE IN LARGE CLUSTER CONFIGURATIONS. | | THESE PROBLEMS INCLUDE THE FOLLOWING: | | A) CI 20 SELF DIRECTED PACKET PROBLEM. | | B) ARBITRATION PROBLEM. | | C) SYNC DETECT PAL COULD LATCH UP UNDER A FLOOD CONDITION. | | D) IMPLEMENTATION OF THE XTEND HDR JUMPER WAS INCORRECT. | | E) ACKNOWLEDGE TURN-AROUND AND BASIC SLOT TIME CAUSING EXCESSIVE COLLISIONS ON THE WIRE. | | F) CORRECT TRAILER TIME TO MEET THE SPEC. | | | | 1. THE FOLLOWING CORRECTIONS ARE IMPLEMENTED BY THIS ECO: | | A) CRC BYTE COUNTER RESET NOW WITH (ILIB ABORT + INIT FNC L) * - (ILIB INIT L). | | B) FIRST TRY FLAG IS NOW INCORPORATED TO PROVIDE REAL ARBITRATION WHERE THE NODE IS NOW SYNCHRONIZED ON | | LOSS OF CARRIER AND WILL OBEY THE RULES OF DUAL ROUND ROBIN ARB. | | C) NEW PAL WILL BE INCORPORATED. | | D) XTEND HDR JUMPER NOW FUNCTIONAL. | | E) INSTALL A CHANGE TO MAKE ALTER DELTA TIME JUMPER SELECT A BASIC SLOT TIME OF 7 TO 10 CLOCK TICKS. | | *QUICK CHECK - (MODULE REV E1) L0100 WITH WIRE FROM A) E65.13 AND E177.13 B) E65.11 AND E177.9 | | *DIAGNOSTIC EVCGD, V1.2 REQUIRED FOR THIS ECO. UPDATED IN DIAGNOSTIC RELEASE 26 (EVNDX 26). | | | |__________________________________________________________________________________________________________________________________| | | | | | | | |TITLE | | DOCUMENT NUMBER | | | | | | | | | | |________________________________| | d | i | g | i | t | a | l | CI780 | Sheet 4 of 12 |SIZE|CODE| NUMBER | REV | | | | | | | | | REVISION MANAGEMENT DOCUMENT | | K | RM | CI780-A-0 | E | |___|___|___|___|___|___|___|____________________________________________________|________________|____|____|________________|_____| ____________________________________________________________________________________________________________________________________ | OPTION NAME | REVISION HISTORY OF | | CI780-AA, -AB, -MA | VAX SBI TO COMPUTER INTERCONNECT ADAPTER (CI780) | |----------------------------------------------------------------------------------------------------------------------------------| | *******************NOTE************************************************************************* | | L0100 JUMPER W1 (MODULE REV E1) OR S3 (MODULE REV E2) INDICATES THE FOLLOWING CONDITIONS: | | A) JUMPER (W1) INSTALLED BETWEEN E177 SOCKET PINS 11 AND 12, OR SWITCH (S3) OPEN, DISABLED: | | | | 1) THIS MAKES THE L0100 DOWNWARDS COMPATIBLE WITH REV. D L0100 MODULES, BY MAINTAINING THE BASIC SLOT COUNT TO | | THE EXISTING COUNT OF SEVEN (7) TICKS, ACKNOWLEDGE TURN-AROUND REMAINS THE SAME AS THE ORIGINAL REV D | | L0100'S, AND THE TRAILER EXTENSION IS NOT ENABLED. WITH THESE ELIMINATED, THE ECO'ED L0100 (REV E) WILL | | MAINTAIN FORM, FIT AND FUNCTION AS THE NON-ECO'ED (REV D) MODULES. HOWEVER, IT SHOULD BE NOTED THAT THE | | FOLLOWING FIXES WILL STILL BE INSTALLED AND BE FUNCTIONAL IN REV E, WHILE IN THE DISABLED POSITION: | | NEW SYNC DETECT PAL, CI20 FIX, XTEND HDR JUMPER, AND XMIT STATUS BIT 3. | | | | B) JUMPER (W1) INSTALLED BETWEEN E177 SOCKET PINS 9 AND 10, OR SWITCH (S3) CLOSED, ENABLED: | | | | 1) BASIC SLOT TIME IS NOW IMPLEMENTED TO TEN (10) TICKS. | | 2) ACK TURN-AROUND CHANGE FULLY IMPLEMENTED. | | 3) TRAILER EXTENSION BY TWO (2) BYTES, FULLY FUNCTIONAL. | | 4) ARBITRATION AND FIRST TRY FLAG FULL IMPLEMENTATION. | | 5) NEW SYNC DETECT PAL, XTEND HDR JUMPER, CI20 AND XMIT STATUS BIT 3, WILL STILL BE FULLY FUNCTIONAL AS ABOVE. | | | | CI780-AA/AB REVISION F1 | | ----------------------- | | *CREATION DATE IS JULY 1986 - MANUFACTURING DATE. | | *THIS REVISION CHANGE INVOLVED AND ECO TO THE L0101 MODULE BRINGING THE MODULE REV TO "J1" | | *PROBLEM/CORRECTION | | L0101-MK009 1.NUMEROUS FUNCTIONAL ERRORS ("ARBITRATION TIMEOUT", INTERNAL QUEUE RETRY ERROR"). | | 2.NEED A VARIABLE SANITY TIMER. | | 3.NEED TO CHECK THE "VALID" BIT WHEN REFERENCING A CACHE BUFFER DESCRIPTION. | | 4.CORRECT DOCUMENTATION ERRORS. | | CORRECTION IS V7.0 CI MICROCODE AND 6 PROMS | | NOTE THAT THE L0101 REV J1 AND CI780.BIN REV 7.0 MUST BE USED TOGETHER | | *AN FCO WILL BE IMPLEMENTED TO UPGRADE ALL CI780'S IN JULY 1986 (CI780-F1-I-005) | | L0101-MK010 1.PATHS CROSSED, "REQID" SENT ON PATH A, RESPONSE ON PATH B. | | 2.CLOCK THE TRANSMIT ENABLE FLOP CORRECTLY TO PREVENT CLUSTER HUNG. | | THIS IS TWO ETCH CUTS AND TWO WIRE ADDS. | | THIS ECO BRINGS THE L0101 TO REV "K1". "J1" AND "K1" ARE BOTH ACCEPTABLE IN CI780 REV "E1". | | | | CI780-AA/AB REVISION E1 | | ---------------------- | | *CREATION DATE IS SEPTEMBER 1985 - MANUFACTURING DATE. | | *FCO INVOLVES A CHANGE TO THE CI MICROCODE ONLY. NEW MICROCODE IS REV 5. | | PROBLEM FIXED: DURING EXTENSIVE IN-HOUSE TESTING OF VERY LARGE VAX CLUSTERS SHOWED THAT UNDER SPECIFIC CONDITIONS THE CI780 | | INTERFACE WILL SOMETIMES INCORRECTLY RECOVER FROM CO ERROR CONDITIONS. | | *AN FCO WILL BE IMPLEMENTED TO UPGRADE ALL CI780 OPTIONS TO REV "E1". IN SEPTEMBER 1985. | | REV. 5 MICROCODE CAN BE OBTAINED IN TWO WAYS: | | 1. OVER THE ENET - COPY VOLKS::CLUSTER$REV:CI780V5.BIN | | 2. OVER EQ KIT - EQ-01365-01 (780 UCODE - REV 5) | | EQ-01365-92 (785 UCODE - REV 5) | | NOTE: THE MINIMUM "SUPPORTING" VERSION OF VMS IS V3.7 FOR THE CI OPTION. VMS IS BEING TRACKED AS PART OF THE "HIGHER | | FUNCTIONALITY" REV-CONTROLLED CLUSTER. REFER TO THE CLUSTER RM DOCUMENT FOR VMS DEPENDENCIES. | |__________________________________________________________________________________________________________________________________| | | | | | | | |TITLE | | DOCUMENT NUMBER | | | | | | | | | | |________________________________| | d | i | g | i | t | a | l | CI780 | Sheet 5 of 12 |SIZE|CODE| NUMBER | REV | | | | | | | | | REVISION MANAGEMENT DOCUMENT | | K | RM | CI780-A-0 | E | |___|___|___|___|___|___|___|____________________________________________________|________________|____|____|________________|_____| ____________________________________________________________________________________________________________________________________ | OPTION NAME | REVISION HISTORY OF | | CI780-AA, -AB, -MA | VAX SBI TO COMPUTER INTERCONNECT ADAPTER (CI780) | |----------------------------------------------------------------------------------------------------------------------------------| | | | CI780-AA/AB REVISION D1 | | ----------------------- | | *CREATION DATE IS APRIL, 1985 - MANUFACTURING SHIP DATE. THIS FCO INVOLVED A CHANGE TO THE MICROCODE ONLY. NEW MICROCODE IS | | REV 4. A FUNCTIONAL PROBLEM WAS DISCOVERED IN VAX CLUSTER TESTING. THE CI780 DID NOT CONFORM TO ARCHITECTUAL SPECIFICATION | | PRODUCING "MISCELLANEOUS" ERRORS TYPE 12 & 13" CAUSING VMS CI--PORT RE-INITS INTRODUCED BY V3. MICROCODE. | | *AN FCO WAS IMPLEMENTED TO UPGRADE ALL CI780 OPTIONS TO REV "D1". (CI780-R00D1) IN APRIL, 1985. | | REV. 4 MICROCODE CAN BE OBTAINED IN TWO WAYS: | | 1. OVER THE ENET - COPY VOLKS::CLUSTER$REV:CI780V4.BIN | | 2. OVER EQ KIT - EQ-01344-02 (780 UCODE - REV 4) | | EQ-01344-03 (785 UCODE - REV 4) | | NOTE: THE MINIMUM "SUPPORTING" VERSION OF VMS IS V3.7 FOR THE CI OPTION VMS IS BEING TRACKED AS PART OF THE "HIGHER | | FUNCTIONALITY" REV-CONTROLLED CLUSTER. REFER TO THE CLUSTER RM DOCUMENT FOR VMS DEPENDENCIES. | | | | | | CI780-AA/AB REVISION C1 | | ----------------------- | | *CREATION DATE WAS NOVEMBER 1984 - MANUFACTURING SHIP DATE. | | *THIS REVISION CHANGE INVOLVED AN ECO TO THE L0101 MODULE BRINGING THE MODULE REV TO "H1" | | *PROBLEM/CORRECTION | | L0101-TW006 - 1.VIRTUAL CIRCUITS ARE CLOSED BE UNRECOGNIZED COMMANDS | | 2.VIRTUAL CIRCUIT CLOSURE DUE TO MICRO CONFUSION. | | 3.PORT HANGS DUE TO CONFLICT IN QUEUE ACCESS. | | CORRECTION IS V3.0 CI MICROCODE | | NOTE THAT L0101 REV H1 AND CI780.BIN REV 3.0 MUST BE USED TOGETHER. | | *AN FCO WAS IMPLEMENTED TO UPGARDE ALL CI780'S IN DECEMBER 1984, (CI780-R00C1) | | *THIS FCO WAS PART OF VAXCLUSTER REV. D1. OTHER FCOS THAT COULD BE NEEDED TO BRING THE CLUSTER TO REV D1 ARE: | | FCO H/W REV | | CI750-R-00B1 REV B1 | | HSC50-R-0006 REV C1 | | RA80X-R-0002 REV B0 | | RA60-R-0003 REV A5 | | | | THESE FCOS SHOULD BE INSTALLED PRIOR TO OR DURING VMS V4.0 INSTALLATION. NOTE THAT ALTHOUGH VMS RELEASE NOTES STATE THAT | | EARLIER REVISIONS ARE ACCEPTABLE,I.E. WILL PROBABLY WORK, ENGINEERING AND PRODUCT MANAGEMENT HAS DETERMINED THAT THE CUSTOMER | | NEEDS ALL THESE FCOS FOR ACCEPTABLE CLUSTER PERFORMANCE UNDER VMS V4.0. | | | | THESE FCO'S SHOULD BE INSTALLED WITH V4.0 FOR ACCEPTABLE CLUSTER PERFORMANCE. | | | | NOTE: THE MINIMUM "SUPPORTING" VERSION OF VMS IS V3.7 FOR THE CI OPTION VMS IS BEING TRACKED AS PART OF THE "HIGHER | | FUNCTIONALITY" REV-CONTROLLED CLUSTER. REFER TO THE CLUSTER RM DOCUMENT FOR VMS DEPENDENCIES. | | | | | | | | | | | | | | | | | |__________________________________________________________________________________________________________________________________| | | | | | | | |TITLE | | DOCUMENT NUMBER | | | | | | | | | | |________________________________| | d | i | g | i | t | a | l | CI780 | Sheet 6 of 12 |SIZE|CODE| NUMBER | REV | | | | | | | | | REVISION MANAGEMENT DOCUMENT | | K | RM | CI780-A-0 | E | |___|___|___|___|___|___|___|____________________________________________________|________________|____|____|________________|_____| ____________________________________________________________________________________________________________________________________ | OPTION NAME | REVISION HISTORY OF | | CI780-AA, -AB, -MA | VAX SBI TO COMPUTER INTERCONNECT ADAPTER (CI780) | |----------------------------------------------------------------------------------------------------------------------------------| | | | CI780-AA/AB REVISION 01 | | ----------------------- | | *CREATION DATE WAS OCTOBER 1983. - MANUFACTURING IMPLEMENTATION. | | *THIS REVISION CHANGE INVOLVED ECOS TO THE L0100,L0101,AND L0102 MODULES AS FOLLOWS: | | L0100-TW003 - CONSTANT CARRIER ON ONE CI PATH MAY PREVENT USE OF THE OTHER PATH. | | L0101-TW004 - 1.LOST CI PACKET UNDER HEAVY LOAD. | | 2.INCORRECT MICROCODE RESULTING IN A LOOP AT ADDRESS 24D. | | L0102-TW003 - INTERMITTENT LOCAL STORE PARITY ERRORS. | | | | THIS MADE THE MODULE REVS AS FOLLOWS: | | L0100 ETCH REV "B" - PART REV "D1" | | ETCH REV "C" - PART REV "D1" | | L0101 ETCH REV "A" - PART REV "F1" | | L0102 ETCH REV "A" - PART REV "C1" | | | | | | | |*QUICK CHECK - L0100 WITH WIRE FROM E122-2 TO E122-3 | | L0101 E114 IS 23-218F3-00 AND AN ETCH CUT SIDE 1, BELOW E239-3 | | L0102 WITH WIRE FROM E69-4 TO E69-12 AND A WIRE FROM E9-12 | | *FCO WAS IMPLEMENTED TO UPGRADE ALL CI780 OPTIONS AND CD KITS. | | *NEW MICROCODE (CI780.BIN VERSION 2) REQUIRED FOR THE FCO. | | *DIAGNOSTICS EVGAA AND EVGAB, VERSION 1.1 REQUIRED. UPDATED IN DIAGNOSTIC RELEASE 14 (EVNDX 14) (AVAILABLE FROM SDC | | NOVEMBER 5, 1983). NEW VERSION FOR BOTH IS 1.1. THESE WERE INCLUDED IN THE FCO KIT - COULD BE ORDERED UNDER PN AS-T599B-ME. | | | | CI780-AA/AB REVISION 00 | | ----------------------- | | *CREATION DATE FOR FCS FOR THIS OPTION-JULY 1982. THIS WAS THE INITIAL INTRODUCTION OF OPTION LEVEL CONTROL FOR THE CI780 AND | | DEFINED THE MINIMUM REVISION LEVEL AT FCS. | | *MINIMUM HARDWARE REVISION OF 11/780 IS REV. 4; MINIMUM WCS PATTERN WAS WCS123. | | *CI780 REQUIRES VMS VERSION 3.1 | | *CI780 MICROCODE RESIDES ON THE 11/780 CONSOLE FLOPPY-VERSION OF THE CONSOLE REQUIRED AT FCS WAS AS-T213A-DE. CONSOLE FLOPPY | | SHIPPED WITH CI780 OPTIONS. | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | |__________________________________________________________________________________________________________________________________| | | | | | | | |TITLE | | DOCUMENT NUMBER | | | | | | | | | | |________________________________| | d | i | g | i | t | a | l | CI780 | Sheet 7 of 12 |SIZE|CODE| NUMBER | REV | | | | | | | | | REVISION MANAGEMENT DOCUMENT | | K | RM | CI780-A-0 | E | |___|___|___|___|___|___|___|____________________________________________________|________________|____|____|________________|_____| 2.4 ____________________________________________________________________________________________________________________________________ | OPTION NAME | R | | | | | | | | | | | | CI780-AA/AB | E | 00 | 01 | C1 | D1 | E1 | F1 | H1 | J1 | K1 | | |______________________________________________|_V_|_______|_______|_______|_______|_______|_______|_______|_______|_______|_______| | PART NO. | DESCRIPTION | |___________|______________________________________________________________________________________________________________________| | | | | | | | | | | | | | |L0100 | CI LINK INTERFACE | B | D |D,(*B2)|D,(*B2)|D,(*B2)| D,B2 | E | N/A | N/A | | |___________|______________________________________|_______|_______|_______|_______|_______|_______|_______|_______|_______|_______| | | | | | | | |JI | | | | | |L0101 | CI CONTROL STORE & PACKET BUFFER | C | E | H | H | H | OR K1| K | K | K | | |___________|______________________________________|_______|_______|_______|_______|_______|_______|_______|_______|_______|_______| | | | | | | | | | | | | | |L0102 | CI DATA PATH | B | C | C | C | C | C | C | C | C | | |___________|______________________________________|_______|_______|_______|_______|_______|_______|_______|_______|_______|_______| | | | | | | | | | | | | | |L0104 | CI SBI INTERFACE FOR CI PORT | C | C | C | C | C | C | C | C | C | | |___________|______________________________________|_______|_______|_______|_______|_______|_______|_______|_______|_______|_______| | | | | | | | | | | | | | |AS-T213*-ME| RX1 VAX 11780 STANDARD CONSOLE | A | D | E | F | H | J | L | L | M | | |___________|______________________________________|_______|_______|_______|_______|_______|_______|_______|_______|_______|_______| | | | | | | | | | | | | | |AS-T793*-ME| RX1A VAX 11785 STANDARD CONSOLE | N/A | N/A | B | C | F | H | K | K | L | | |___________|______________________________________|_______|_______|_______|_______|_______|_______|_______|_______|_______|_______| | | | | | | | | | | | | | |7017654 | BACKPLANE ASSEMBLY | A | A | A | A | A | A | A | A | A | | |___________|______________________________________|_______|_______|_______|_______|_______|_______|_______|_______|_______|_______| | | | | | | | | | | | | | |7014956-00 | POWER SUPPLY (CI780-AA) | * | * | * | * | * | * | * | * | * | | |___________|______________________________________|_______|_______|_______|_______|_______|_______|_______|_______|_______|_______| | | | | | | | | | | | | | |7014956-00 | POWER SUPPLY (CI780-AA) | * | * | * | * | * | * | * | * | * | | |___________|______________________________________|_______|_______|_______|_______|_______|_______|_______|_______|_______|_______| | | | | | | | | | | | | | |EVNDX | VAX DIAGNOSTIC RELEASE | #12 | #17 | #18 | #20 | #21 | #24 | #26 | #28 | #28 | | |___________|______________________________________|_______|_______|_______|_______|_______|_______|_______|_______|_______|_______| |** | | | | | | | | | | | | |CI780.BIN | CI MICROCODE FILES | | | | | 5.0 | 7.0 | 7.0 | 7.0 | 8.7 | | |___________|______________________________________|_______|_______|_______|_______|_______|_______|_______|_______|_______|_______| | | | | | | | | | | | | | | L0118 | CI ENHANCED LINK INTERFACE | - | - | - | - | - | - | - | B2 | B2 | | |___________|______________________________________|_______|_______|_______|_______|_______|_______|_______|_______|_______|_______| | NOTES: | R | | | | | | | | | | | | | ALL REVS ARE MINIMUM REVS | E H | E | | | | | | C M | C M | C M | C T | | | | V I | C | | | | | | I K | I K | I K | I W | | | *"B2" EQUAL TO "D" | I S | O | | | | | | 7 0 | 7 0 | 7 0 | 7 0 | | | | S T | | | | | | | 8 0 | 8 0 | 8 0 | 8 0 | | |**MINIMUM REVISION REQUIRED | I O | N | | | | | | 0 3 | 0 4 | 0 5 | 0 6 | | | .BIN REV IS COMPRISED OF RAM.ROM | O R | O | | | | | | | | | | | | @REV IS PART OF CONSOLE P/N | N Y |___|_______|_______|_______|_______|_______|_______|_______|_______|_______|_______| | | | D | / | / | / | / |10/ |02/ |12/ |05/ |09/ | / | | Revision Matrix (Top Level | | A | / | / | / | / | 15/ | 26/ | 16/ | 30/ | 18/ | / | | and Compatibility) | | T | | | | | 85 | 87 | 87 | 88 | 90 | | |_____________________________________|________|_E_|_______|_______|_______|_______|_______|_______|_______|_______|_______|_______| | | | | | | | |TITLE | | DOCUMENT NUMBER | | | | | | | | | | |________________________________| | d | i | g | i | t | a | l | CI780 | Sheet 8 of 12 |SIZE|CODE| NUMBER | REV | | | | | | | | | REVISION MANAGEMENT DOCUMENT | | K | RM | CI780-A-0 | E | |___|___|___|___|___|___|___|____________________________________________________|________________|____|____|________________|_____| ____________________________________________________________________________________________________________________________________ | OPTION NAME | REVISION HISTORY OF | | CI780-AA, -AB, -MA | VAX SBI TO COMPUTER INTERCONNECT ADAPTER (CI780) | |----------------------------------------------------------------------------------------------------------------------------------| | CI780-MA REVISION K1 | | -------------------- | | *CREATION DATE IS SEPT 1990 | | *THIS REVISION CHANGED THE CI780 FROM "J" TO "K" | | *THIS REVISION UPDATES THE DOCUMENT TO CORRECTLY LIST THE MINIMUM COMPATABLE PART REVISIONS OF THE CI780 | | *QUICK CHECK - VERIFY PRESENCE OF CI780-MA OPTION REV K1. | | *DIAGNOSTIC RELEASE 28 (EVNDX 28). Contains the minimum usable diagnostics for the L0118 Module | | | | CI780-MA REVISION J1 | | -------------------- | | *CREATION DATE IS MAY 1988. | | *THIS REVISION CHANGED THE CI780 FROM "H" TO "J" | | *THIS REVISION DOCUMENTS THE INTRODUCTION OF THE L0118 IN PLACE OF THE L0100. | | *PROBLEM/CORRECTION - (N/A) | | *QUICK CHECK - VERIFY L0118 MODULE INSTALLED. | | *DIAGNOSTIC RELEASE 28 (EVNDX 28). Contains the minimum usable diagnostics for the L0118 Module | | | | THIS IS THE INITIAL INTRODUCTION OF THE REVISION MATRIX ON THE CI780-MA | | | | CI780 REVISION H1 | | ----------------- | | *CREATION DATE IS JUNE 1987 | | *THIS REVISION CHANGED THE CI780 FROM "F" TO "H". | | *THIS REVISION CHANGE INVOLVED AN ECO TO THE L0100 MODULE BRINGING THE MODULE REV TO "E" | | *PROBLEM/CORRECTION | | LO100-MK006 1. ORIGINAL 140 MHZ CLOCK AND ASSOCIATED HARDWARE HAS TENDENCY TO DRIFT OFF FREQUENCY. | | 2. EXISTING WIRES CAUSED BY ECO #MK005 CAUSE EXTENSIVE MANUFACTURING COSTS. | | THE FOLLOWING CORRECTIONS ARE IMPLEMENTED BY THIS ECO: | | 1. CHANGE 140 MHZ CRYSTAL TO NEW HYBRID OSCILLATOR (PN 18-23940-01) AND DELETE UNNECESSARY HARDWARE. | | 2. PHASE IN NEW ETCH TO REMOVE WIRE'S ON MODULE. | | | | L0100-MK005 1. MAJOR PROBLEMS IN THE INTERFACE WHICH WOULD BE HIGHLY VISIBLE IN LARGE CLUSTER CONFIGURATIONS. | | THESE PROBLEMS INCLUDE THE FOLLOWING: | | A) CI 20 SELF DIRECTED PACKET PROBLEM. | | B) ARBITRATION PROBLEM. | | C) SYNC DETECT PAL COULD LATCH UP UNDER A FLOOD CONDITION. | | D) IMPLEMENTATION OF THE XTEND HDR JUMPER WAS INCORRECT. | | E) ACKNOWLEDGE TURN-AROUND AND BASIC SLOT TIME CAUSING EXCESSIVE COLLISIONS ON THE WIRE. | | F) CORRECT TRAILER TIME TO MEET THE SPEC. | | 1. THE FOLLOWING CORRECTIONS ARE IMPLEMENTED BY THIS ECO: | | A) CRC BYTE COUNTER RESET NOW WITH (ILIB ABORT + INIT FNC L) * - (ILIB INIT L). | | B) FIRST TRY FLAG IS NOW INCORPORATED TO PROVIDE REAL ARBITRATION WHERE THE NODE IS NOW SYNCHRONIZED ON | | LOSS OF CARRIER AND WILL OBEY THE RULES OF DUAL ROUND ROBIN ARB. | | C) NEW PAL WILL BE INCORPORATED. | | D) XTEND HDR JUMPER NOW FUNCTIONAL. | | E) INSTALL A CHANGED TO MAKE ALTER DELTA TIME JUMPER SELECT A BASIC SLOT TIME OF 7 OR 10 CLOCK TICKS. | | *QUICK CHECK - (MODULE REV E1) L0100 WITH WIRE FROM A) E65.13 AND E177.13 B) E65.11 AND E177.9 | | *DIAGNOSTIC EVCGD, V1.2 REQUIRED FOR THIS ECO. UPDATED IN DIAGNOSTIC RELEASE 26 (EVNDX 26). | |__________________________________________________________________________________________________________________________________| | | | | | | | |TITLE | | DOCUMENT NUMBER | | | | | | | | | | |________________________________| | d | i | g | i | t | a | l | CI780 | Sheet 9 of 12 |SIZE|CODE| NUMBER | REV | | | | | | | | | REVISION MANAGEMENT DOCUMENT | | K | RM | CI780-A-0 | E | |___|___|___|___|___|___|___|____________________________________________________|________________|____|____|________________|_____| ____________________________________________________________________________________________________________________________________ | OPTION NAME | REVISION HISTORY OF | | CI780-AA, -AB, -MA | VAX SBI TO COMPUTER INTERCONNECT ADAPTER (CI780) | |----------------------------------------------------------------------------------------------------------------------------------| | ********************NOTE***************************************** | | L0100 JUMPER W1 (MODULE REV E1) OR S3 (MODULE REV E2) INDICATES THE FOLLOWING CONDITIONS: | | A) JUMPER (W1) INSTALLED BETWEEN E177 SOCKET PINS 11 AND 12, OR SWITCH (S3) OPEN, DISABLED: | | | | 1) THIS MAKES THE L0100 DOWNWARDS COMPATIBLE WITH REV. D L0100 MODULES, BY MAINTAINING THE BASIC SLOT COUNT | | TO THE EXISTING COUNT OF SEVEN (7) TICKS, ACKNOWLEDGE TURN-AROUND REMAINS THE SAME AS THE ORIGINAL | | REV D L0100'S, AND THE TRAILER IS NOT ENABLED. WITH THESE ELIMINATED, THE ECO'ED L0100 (REV E) WILL | | MAINTAIN FORM, FIT AND FUNCTION AS THE NON-ECO'ED (REV D) MODULES. HOWEVER, IT SHOULD BE NOTED THAT THE | | FOLLOWING FIXES WILL STILL BE INSTALLED AND BE FUNCTIONAL IN REV E, WHILE IN THE DISABLED POSITION: | | NEW SYNC DETECT PAL, CI20 FIX, XTEND HDR JUMPER AND XMIT STATUS BIT 3. | | | | B) JUMPER (W1) INSTALLED BETWEEN E177 SOCKET PINS 9 AND 10, OR SWITCH (S3) CLOSED, ENABLED: | | | | 1) BASIC SLOT TIME NOW IMPLEMENTED TO TEN (10) TICKS | | 2) ACK TURN-AROUND CHANGE FULLY IMPLEMENTED. | | 3) TRAILER EXTENSION BY TWO (2) BYTES, FULLY FUNCTIONAL. | | 4) ARBITRATION AND FIRST TRY FLAG FULL IMPLEMENTATION. | | 5) NEW SYNC DETECT PAL, XTEND HDR JUMPER, CI20 AND XMIT STATUS BIT 3, WILL STILL BE FULLY FUNCTIONAL AS ABOVE| | | | CI780-MA REVISION F1 | | --------------------- | | *CREATION DATE IS JULY 1986 - MANUFACTURING DATE. | | *THIS REVISION CHANGE INVOLVED AND ECO TO THE L0101 MODULE BRINGING THE MODULE REV TO "J1" | | *PROBLEM/CORRECTION | | L0101-MK009 1.NUMEROUS FUNCTIONAL ERRORS ("ARBITRATION TIMEOUT", INTERNAL QUEUE RETRY ERROR"). | | 2.NEED A VARIABLE SANITY TIMER. | | 3.NEED TO CHECK THE "VALID" BIT WHEN REFERENCING A CACHE BUFFER DESCRIPTION. | | 4.CORRECT DOCUMENTATION ERRORS. | | CORRECTION IS V7.0 CI MICROCODE AND 6 PROMS | | NOTE THAT THE L0101 REV J1 AND CI780.BIN REV 7.0 MUST BE USED TOGETHER | | *AN FCO WILL BE IMPLEMENTED TO UPGRADE ALL CI780'S IN JULY 1986 (CI780-F1-I-005) | | L0101-MK010 1.PATHS CROSSED, "REQID" SENT ON PATH A, RESPONSE ON PATH B. | | 2.CLOCK THE TRANSMIT ENABLE FLOP CORRECTLY TO PREVENT CLUSTER HUNG. | | THIS IS TWO ETCH CUTS AND TWO WIRE ADDS. | | THIS ECO BRINGS THE L0101 TO REV "K1". "J1" AND "K1" ARE BOTH ACCEPTABLE IN CI780 REV "E1". | | | | CI780-MA REVISION E1 | | -------------------- | | *CREATION DATE IS SEPTEMBER 1985 - MANUFACTURING DATE. | | *FCO INVOLVES A CHANGE TO THE CI MICROCODE ONLY. NEW MICROCODE IS REV 5. | | PROBLEM FIXED: DURING EXTENSIVE IN-HOUSE TESTING OF VERY LARGE VAX CLUSTERS SHOWED THAT UNDER SPECIFIC CONDITIONS THE CI780 | | INTERFACE WILL SOMETIMES INCORRECTLY RECOVER FROM CI ERROR CONDITIONS. VAX 8600'S WERE UPGRADE BY MFG. | | | | NOTE: THE MINIMUM "SUPPORTING" VERSION OF VMS IS V3.7 FOR THE CI OPTION. VMS IS BEING TRACKED AS PART OF THE "HIGHER | | FUNCTIONALITY" REV-CONTROLLED CLUSTER. REFER TO THE CLUSTER RM DOCUMENT FOR VMS DEPENDENCIES. | | | | AN FCO WAS NOT DONE FOR THIS REV. UPDATING WAS DONE BY MFG. | | | | CI780-MA REVISION D1 | | -------------------- | | *CREATION DATE IS APRIL, 1985 - MANUFACTURING SHIP DATE. THIS FCO INVOLVED A CHANGE TO THE MICROCODE ONLY. NEW MICROCODE IS | | REV 4. A FUNCTIONAL PROBLEM WAS DISCOVERED IN VAX CLUSTER TESTING. THE CI780 DID NOT CONFORM TO ARCHITECTUAL SPECIFICATION | | PRODUCING "MISCELLANEOUS ERRORS TYPE 12 & 13" CAUSING VMS CI--PORT RE-INITS INTRODUCED BY V3. MICROCODE. | | | | AN FCO WAS NOT DONE FOR THIS REV. UPDATING WAS DONE BY MFG. | |__________________________________________________________________________________________________________________________________| | | | | | | | |TITLE | | DOCUMENT NUMBER | | | | | | | | | | |________________________________| | d | i | g | i | t | a | l | CI780 | Sheet 10 of 12 |SIZE|CODE| NUMBER | REV | | | | | | | | | REVISION MANAGEMENT DOCUMENT | | K | RM | CI780-A-0 | E | |___|___|___|___|___|___|___|____________________________________________________|________________|____|____|________________|_____| ____________________________________________________________________________________________________________________________________ | OPTION NAME | REVISION HISTORY OF | | CI780-AA, -AB, -MA | VAX SBI TO COMPUTER INTERCONNECT ADAPTER (CI780) | |----------------------------------------------------------------------------------------------------------------------------------| | NOTE: THE MINIMUM "SUPPORTING" VERSION OF VMS IS V3.7 FOR THE CI OPTION VMS IS BEING TRACKED AS PART OF THE "HIGHER | | FUNCTIONALITY" REV-CONTROLLED CLUSTER. REFER TO THE CLUSTER RM DOCUMENT FOR VMS DEPENDENCIES. | | | | CI780-MA REVISION C1 | | -------------------- | | THIS RM REPRESENTS THE MINIMUM REVISION LEVEL "C" AT FCS, MARCH 1985 | | | | *CREATION DATE WAS NOVEMBER 1984 - MANUFACTURING SHIP DATE. | | *THIS REVISION CHANGE INVOLVED AN ECO TO THE L0101 MODULE BRINGING THE MODULE REV TO "H1" | | *PROBLEM/CORRECTION | | L0101-TW006 1.VIRTUAL CIRCUITS ARE CLOSED BY UNRECOGNIZED COMMANDS | | 2.VIRTUAL CIRCUIT CLOSURE DUE TO MICRO CONFUSION. | | 3.PORT HANGS DUE TO CONFLICT IN QUEUE ACCESS. | | CORRECTION IS V3.0 CI MICROCODE. | | NOTE THAT L0101 REV H1 AND CI780.BIN REV 3.0 MUST BE USED TOGETHER | | NOTE: THE MINIMUM "SUPPORTING" VERSION OF VMS IS V3.7 FOR THE CI OPTION VMS IS BEING TRACKED AS PART OF THE "HIGHER | | FUNCTIONALITY" REV-CONTROLLED CLUSTER. REFER TO THE CLUSTER RM DOCUMENT FOR VMS DEPENDENCIES. | | | | THIS IS THE INITIAL INTRODUCTION OF THE REVISION MATRIX ON THE CI780-MA | | | | THIS IS THE VARIATION THAT SHIPS WITH VAX 8600. ALTHOUGH THE CI780-MA BEGINS WITH REVISION E1, EARLIER REVS OF THE CI OPTION | | WERE SHIPPED ON VAX 8600'S AND ARE BEING NOTED HERE. | | 3.1 | | CI780-MA REVISION 01 (THIS IS BEING LISTED FOR INFORMATION ONLY - THIS REV WAS NOTED IN THE VAX 8600 DOCUMENT BUT WAS NOT | | -------------------- SHIPPED.) | | | | *CREATION DATE WAS OCTOBER 1983. - MANUFACTURING IMPLEMENTATION. | | *THIS REVISION CHANGE INVOLVED ECOS TO THE L0100,L0101,AND L0102 MODULES AS FOLLOWS: | | L0100-TW003 - CONSTANT CARRIER ON ONE CI PATH MAY PREVENT USE OF THE OTHER PATH. | | L0101-TW004 - 1.LOST CI PACKET UNDER HEAVY LOAD. | | 2.INCORRECT MICROCODE RESULTING IN A LOOP AT ADDRESS 24D. | | L0102-TW003 - INTERMITTENT LOCAL STORE PARITY ERRORS. | | THIS MADE THE MODULE REVS AS FOLLOWS: | | L0100 ETCH REV "B" - PART REV "D1" | | ETCH REV "C" - PART REV "D1" | | L0101 ETCH REV "A" - PART REV "F1" | | L0102 ETCH REV "A" - PART REV "C1" | | *QUICK CHECK - L0100 WITH WIRE FROM E122-2 TO E122-3 | | L0101 E114 IS 23-218F3-00 AND AN ETCH CUT SIDE 1, BELOW E239-3 | | L0102 WITH WIRE FROM E69-4 TO E69-12 AND A WIRE FROM E9-12 | | *DIAGNOSTICS EVGAA AND EVGAB, VERSION 1.1 REQUIRED. UPDATED IN DIAGNOSTIC RELEASE 14 (EVNDX 14) (AVAILABLE FROM SDC | | NOVEMBER 5, 1983). NEW VERSION FOR BOTH IS 1.1. | | | | | | | | | | | | | | | |__________________________________________________________________________________________________________________________________| | | | | | | | |TITLE | | DOCUMENT NUMBER | | | | | | | | | | |________________________________| | d | i | g | i | t | a | l | CI780 | Sheet 11 of 12 |SIZE|CODE| NUMBER | REV | | | | | | | | | REVISION MANAGEMENT DOCUMENT | | K | RM | CI780-A-0 | E | |___|___|___|___|___|___|___|____________________________________________________|________________|____|____|________________|_____| ____________________________________________________________________________________________________________________________________ | OPTION NAME | R | | | | | | | | | | | | CI780-MA | E | 00 | 01 | C1 | D1 | E1 | F1 | H1 | J1 | K1 | | |______________________________________________|_V_|_______|_______|_______|_______|_______|_______|_______|_______|_______|_______| | PART NO. | DESCRIPTION | |___________|______________________________________________________________________________________________________________________| | | | | | | | | | | | | | |L0100 | CI LINK INTERFACE | N/A | D |D,(*B2)|D,(*B2)|D,(*B2)| D,B2 | E | N/A | N/A | | |___________|______________________________________|_______|_______|_______|_______|_______|_______|_______|_______|_______|_______| | | | | | | | |J1 | | | | | |L0101 | CI CONTROL STORE & PACKET BUFFER | N/A | E | H | H | H | OR K1| K | K | K | | |___________|______________________________________|_______|_______|_______|_______|_______|_______|_______|_______|_______|_______| | | | | | | | | | | | | | |L0102 | CI DATA PATH | N/A | C | C | C | C | C | C | C | C | | |___________|______________________________________|_______|_______|_______|_______|_______|_______|_______|_______|_______|_______| | | | | | | | | | | | | | |L0104 | CI SBI INTERFACE FOR CI PORT | N/A | C | C | C | C | C | C | C | C | | |___________|______________________________________|_______|_______|_______|_______|_______|_______|_______|_______|_______|_______| | | | | | | | | | | | | | |BC-T987E-ME| CONSOLE WITH NO DIAGS. | | | | | E | OBS | OBS | OBS | OBS | | |___________|______________________________________|_______|_______|_______|_______|_______|_______|_______|_______|_______|_______| | | | | | | | | | | | | | |BC-T989E-DE| CONSOLE WITH DIAGS. | | | | | E | OBS | OBS | OBS | OBS | | |___________|______________________________________|_______|_______|_______|_______|_______|_______|_______|_______|_______|_______| |** | | | | | | | | | | | | |CI780.BIN | CI MICROCODE FILES | | | | | 5.0 | 7.0 | 7.0 | 7.0 | 8.7 | | |___________|______________________________________|_______|_______|_______|_______|_______|_______|_______|_______|_______|_______| |@ | | | | | | | | | | | | |BC-FI17*-ME| CONSOLE WITH NO DIAGS. | | | | | | A | D | D | E | | |___________|______________________________________|_______|_______|_______|_______|_______|_______|_______|_______|_______|_______| |@ | | | | | | | | | | | | |BC-FI18*-DE| CONSOLE WITH DIAGS | | | | | | A | D | D | E | | |___________|______________________________________|_______|_______|_______|_______|_______|_______|_______|_______|_______|_______| | | | | | | | | | | | | | |EVNDX | VAX DIAGNOSTIC RELEASE | #12 | #17 | #18 | #20 | #21 | #24 | #26 | #28 | #28 | | |___________|______________________________________|_______|_______|_______|_______|_______|_______|_______|_______|_______|_______| | | | | | | | | | | | | | | L0118 | CI ENHANCED LINK INTERFACE | - | - | - | - | - | - | - | B2 | B2 | | |___________|______________________________________|_______|_______|_______|_______|_______|_______|_______|_______|_______|_______| | | | | | | | | | | | | | | | | | | | | | | | | | | |___________|______________________________________|_______|_______|_______|_______|_______|_______|_______|_______|_______|_______| | NOTES: | R | | | | | | | | | | | | | ALL REVS ARE MINIMUM REVS | E H | E | | | | | | C M | C M | C M | C T | | | | V I | C | | | | | | I K | I K | I K | I W | | | *"B2" EQUAL TO "D" | I S | O | | | | | | 7 0 | 7 0 | 7 0 | 7 0 | | | | S T | | | | | | | 8 0 | 8 0 | 8 0 | 8 0 | | |**MINIMUM REVISION REQUIRED | I O | N | | | | | | 0 3 | 0 4 | 0 5 | 0 6 | | | .BIN REV IS COMPRISED OF RAM.ROM | O R | O | | | | | | | | | | | | @REV IS PART OF CONSOLE P/N | N Y |___|_______|_______|_______|_______|_______|_______|_______|_______|_______|_______| | | | D | / |11/ |03/ |03/ |10/ |02/ |12/ |05/ |09/ | / | | Revision Matrix (Top Level | | A | / | 17/ | 15/ | 15/ | 15/ | 26/ | 18/ | 30/ | 18/ | / | | and Compatibility) | | T | | 83 | 85 | 85 | 85 | 87 | 87 | 88 | 90| | |_____________________________________|________|_E_|_______|_______|_______|_______|_______|_______|_______|_______|_______|_______| | | | | | | | |TITLE | | DOCUMENT NUMBER | | | | | | | | | | |________________________________| | d | i | g | i | t | a | l | CI780-MA | Sheet 12 of 12 |SIZE|CODE| NUMBER | REV | | | | | | | | | REVISION MANAGEMENT DOCUMENT | | K | RM | CI780-A-0 | E | |___|___|___|___|___|___|___|____________________________________________________|________________|____|____|________________|_____| \\VAX_REV_MATRIX