_ DEC-O-LOG for DEBNI _ DOL, DEBNI-O001, T1034-YA Module, MAY 90 PROBLEM: 1.) When using the SHOW STATUS command in the DEBNI console monitor program, there is a potential to inadertently write to host memory. 2.) Using the SHOW STATUS/TOTAL command in the DEBNI console monitor program may cause a machine check. 3.) The text displayed on the screen during the SHOW ERROR command in the DEBNI console monitor program is out of order. 4.) The registers in the hard error block were saved in backwards order. 5.) The false overflow count on the LANCE chip will not be valid if the ERR bit is set. FIELD EFFECTIVITY: Retrofit all T1034-YA DEBNI modules that are Rev. B5, B6 or B7. This FCO incorporates ECO T1034-YA-MK002 - New Part Revision "C5", "C6", and "C7". Field spares stock should also be upgraded. QUICK CHECK: Revision "C5", "C6", "C7". Look for 23-562E6-00 at location E13. The device register (dtype) should contain "03000118". FCO KIT ORDERING: EQ-01582-02 T1034-YA Module FA-04911-02 FCO Document