_ FCO DELNI-S001, Transformer may short to DELNI-BA chassis +-----------------------------------------------------------------------------+ | | | _ _ _ _ _ _ _ Level of Urgency Page_1_ | || | | | | | | | +--+ Of_4_ | ||d|i|g|i|t|a|l| FCO | S| | ||_|_|_|_|_|_|_| +--+ | |_____________________________________________________________________________| | | | FIELD CHANGE ORDER Number: DELNI-S001 | |_____________________________________________________________________________| | Applicability: | | ALL AND ONLY REVISION "A1" DELNI-BA with the following serial numbers. | | (See serial number list, Page 2) | | | |_____________________________________________________________________________| | Problem/Symptom: | | | | DELNI-BA Rev "A1" with the specified serial numbers have the | | potential of causing a safety hazard. Transformer (16-20578-02) in | | 7020255-00 subassembly may short to DELNI-BA chassis. | | | | | | DELNI-BA at Revision "C1". | |_____________________________________________________________________________| | Compatibility/Prerequisite FCO: | Est. Time to Install: | | N/A | 1.5 hr. | | | | |_____________________________________________________________________________| | Special Tools or Test Equipment: | | N/A | |_____________________________________________________________________________| | FCO Parts Information | |_____________________________________________________________________________| | Order by Quantity: Part Number: Description: | | FCO Kit#: | | EQ-01537-01 1 DELNI-BA Local Network Interconnect/120V | | | | FA-04842-01 1 FCO Document | |_____________________________________________________________________________| |EQ Kit Variation System/Option Applic: DELNI-BA | |_____________________________________________________________________________| | Approvals | |_____________________________________________________________________________| | CSSE Engineer | F.S. Product Safety | F.S. Logistics | | Richard Woodward | Robert Brister | Sylvester Wilkins | |____________________|__________________________|_____________________________| | CSSE Manager | F.S. Microfiche Libraries| Affected Population: | | Jonathan Lewis | | 955 | |____________________| EP-FSVDC-LB VAXDOC |____________________________ | | MicroMedia Pub | | Initial Kitting: | | Diane MacDonald | VAXnotes | 955 | |____________________| STARS |____________________________ | | Revision: | | Hardcopy Publication: | | A | | 1,000 | |____________________| |_____________________________| | FCO Release Date | | Parts Availability: | | 27-MAR-89 | | March, 1989 | +-----------------------------------------------------------------------------+ _ _ _ _ _ _ _ | FCO DELNI-S001 | | | | | | | | | |d|i|g|i|t|a|l| | PAGE 2 OF 4 |_|_|_|_|_|_|_| | | _______________________________|_________________________________________ Affected Serial Numbers This safety problem has been isolated to the following serial numbers: DELNI-BA -------- AS84165 AS84166 AS84167 AS84168 AS84169 AS84171 AS84175 AS84176 AS84199 AS84200 AS84201-AS84300 AS84301-AS84400 AS84401-AS84500 AS84501-AS84600 AS84601-AS84650 AS84651-AS84727 AS84736 AS84739 AS84742-AS84750 AS84801-AS84833 AS84835-AS84837 AS84879 AS84888-AS84900 AS84901-AS85000 AS85001-AS85100 AS85101-AS85200 AS85201-AS85300 AS85293-FIELD SERVICE _ _ _ _ _ _ _ | FCO DELNI-S001 | | | | | | | | | |d|i|g|i|t|a|l| | PAGE 3 OF 4 |_|_|_|_|_|_|_| | | _______________________________|_________________________________________ REWORK INSTRUCTIONS 1. Obtain the Customer's permission and perform all necessary procedures to remove the DELNI from the network. 2. Remove power from the DELNI by disconnecting the AC power cord from the outlet. ******************************************************************************* * *** CAUTION *** * * To assure that the AC power is removed from the unit, the AC power cord * * must be disconnected. * ******************************************************************************* 3. Disconnect all the remaining cables from the rear of the DELNI. 4. Remove and replace the Revision "A1" DELNI-BA with the Revision "C1" DELNI-BA supplied in this EQ Kit, # EQ-01537-01. 5. Insure that the LOCAL/GLOBAL MODE SWITCH as well as the 120V/240V SELECT SWITCH for the DELNI-BA are in the proper positions. If unsure of the correct settings refer to the unit that was just removed from the Network in step 4 (above), or consult the DELNI Installation Manual. 6. Reverse sequence steps 3 thru 1 to restore the DELNI back to normal operation. 7. Verification of the DELNI-BA in a DECNET environment is accomplished by issuing the SET HOST command to a remote node. 8. Complete LARS data as per example on Page 4 of 4. 9. Update the Site Management Guide to reflect installation of this FCO. _ _ _ _ _ _ _ | FCO DELNI-S001 | | | | | | | | | |d|i|g|i|t|a|l| | PAGE 4 OF 4 |_|_|_|_|_|_|_| | | _______________________________|_________________________________________ LARS CATEGORY S USA GIA EUROPE Activity - Contract and Warranty W U Y Non Contract/Non Warranty* F F F RTD/Off-site Agreement F DEC Option DELNI DELNI DELNI Type of Call M M M Action Taken D D I Fail Area-Module-FCO-Comments DELNI-S001 DELNI-S001 DELNI-S001 Material Used EQ-01537-01 EQ-01537-01 EQ-01537-01 (a) Warranty Optimum, Warranty Standard and Warranty Basic (on-site) Agreements; * Note material (only) free of charge for all customers. (b) RTD=Return to Digital or Off-site Agreements; If Field Engineer ON-site, use Activity Code "F". \^ DELNI \\DELNI \\WOODWARD \\1989 \\MAR \\FCO_DOCS