_ FCO CK-DELUA-M001, Potential safety hazard/improper fuse insertion +-----------------------------------------------------------------------------+ | | | _ _ _ _ _ _ _ Level of Urgency Page 1 | || | | | | | | | +--+ Of 5 | ||d|i|g|i|t|a|l| FCO |M | | ||_|_|_|_|_|_|_| +--+ | |_____________________________________________________________________________| | | | FIELD CHANGE ORDER Number: CK-DELUA-M001 | |_____________________________________________________________________________| | Applicability: Rework all DELUA Interface Bulkhead Assemblies (P/N 70-18799)| | with fuse. This FCO implements ECO #5415552. This FCO doesn't apply | | to Bulkhead assemblies with circuit breakers. | | | |_____________________________________________________________________________| | Problem/Symptom: There exists a potential safety hazard if an improper fuse | | is inserted in F1 of the Ethernet Controller Interface Bulhead Assembly. | | | |_____________________________________________________________________________| | Quick Check: Tab #1 of the fuse assembly should have 18AWG wire with shrink | | tubing. | |_____________________________________________________________________________| | Compatibility/Prerequisite FCO: None | Est. Time to Install: | | | 0.9 Hours | |___________________________________________________|_________________________| | Special Tools or Test Equipment: None | | | |_____________________________________________________________________________| | FCO Parts Information | |_____________________________________________________________________________| | Order by Quantity: Part Number: Description: | | FCO Kit#: | | EQ-01434-01 1 70-22783-02 Fused jumper wire assembly| | | | FA-04720-01 1 FCO Document | |_____________________________________________________________________________| |EQ Kit Variation System/Option Applic: | |_____________________________________________________________________________| | Approvals | |_____________________________________________________________________________| | CSSE Engineer | F.S. Product Safety | F.S. Logistics | | Dave Waterman | William Henry | Ed Duggan | |____________________|__________________________|_____________________________| | CSSE Manager | F.S. Microfiche Libraries| Affected Population: | | Charles Payne | EP-FSNVX-LB VAX | 150 | |____________________| EP-FSP11-LB PDP11 |____________________________ | | MicroMedia Pub | | Initial Kitting: | | Ray LeBlanc | VAXnotes | 150 | |____________________| STARS |____________________________ | | Revision: | | Hardcopy Publication: | | A | | 200 | |____________________| |_____________________________| | FCO Release Date | | Parts Availability: | | 15-Mar-87 | | January 1987 | +-----------------------------------------------------------------------------+ _ _ _ _ _ _ _ | FCO CK-DELUA-M001 | | | | | | | | | |d|i|g|i|t|a|l| | PAGE 2 OF 5 |_|_|_|_|_|_|_| | | _______________________________|_________________________________________ REWORK PROCEDURE 1) Remove cables to and from the bulkhead assembly. 2) Loosen the four captive screws holding the assembly to the mounting bracket and remove the bulkhead assembly to an appropiate work area. 3) Remove wire tab from underside of fuseholder and unsolder far end of this wire from the ciruit board. 4) Install wire fuse assembly (70-22783-02) from EQ kit in place of the wire removed in step #3. 5) Re-install bulkhead assembly into mounting bracket and reconnect the cables to and from the bulkhead assembly. 6) The installation is correct and complete if the POWER LED is illuminated. 7) Complete LARS report as per attached sample. \^ DELUA \\DELUA \\CK-DELUA \\WATERMAN \\1987 \\MAR \\FCO_DOCS