_ DEC-O-LOG for DMZ32 _ DOL, DMZ32-I001, M8398 MAY 87 Problem: 1. Flush bit not clearing DMA correctly. Symptom: File corruption on unibus disk controller drives and some users getting other users data. System errorlogger logs "IMR" invalid map register errors. This bug requires that "DMA" mode be turned off on all DMZ32 lines on the system. This is a VAX/VMS specific problem. 2. Problem: SSYNC timeout counter starts before NPG is received [NXM error]. Symptom: This causes Ultrix and UNIX systems to hang and or crash based on operating system environment at the time of the timeout. 3. Problem: When H3014 is powered off/on, DTR is not reasserted by microcode. Symptom: Terminal lines set up as modem will not be able to connect to system, as well as users logged in through modem connections will be dropped due to no "DTR ON" status. System must be rebooted to reenable modem lines. 4. Problem: Unsupported baud rates cause microcode to hang. Symptom: If un-suspecting user tries to set terminal to one of the two unsupported baud rates, the DMZ32 microcode will hang and the device will be unusable to the system. A total system reboot is required to clear the condition. 5. Problem: NXM error sets the wrong bit in Octet CSR. Symptom: No error reports from field, but if NXM were to occur, the YC-driver would not be notified of it's occurrence. This could have serious implications on 8XXX systems with DWBUA [unibus adapter]. 6. Problem: Self test code constants enabled at wrong time. Symptom: None reported from Field, but was discovered during internal testing of DMZ32 microcode. 7. Problem: Foreign terminals sending abutted characters lose trailing bits. Symptom: Files get invalid escape sequence data while editing using the "arrow" cursor positioning keys. FIELD EFFECTIVITY: Replace Revision E1 or earlier M8398 module with a Revision F1 or latter to incorporate new UBI microcode version 16 and TIU microcode version 1C when problem/symptoms are evident. Phase M8398 Revision "F1" module into spares stock by 14 March 1987 as per ECO M8398-MK003. Purge stockroom 17 and all Field Service Stockrooms by 1 April 1987. QUICK CHECK: Presence of ROM 315F4 in location E135, ROM 155D2 in E145. FCO KIT ORDERING: EQ-01457-01 FCO, PARTS FA-04743-01 FCO only