_ DEC-O-LOG for DN200 _ DOL, DN200-R0004, DMR11-AD JUL 84 PROBLEM: An update to the DMR11-AD specification indictes a possible overload of the +5v Regulators under the maximum configuration. 2. Due to the NPR latency the DNSXX-AB 9DMC11) must preceed the DMR11-AD on the Unibus when used in a high speed sychronous configuration. CORRECTION: Re-distribute the load by re-arranging the Module Utilization. In a fixed configuration the DNSXX-AB (DMC11) requires placement ahead of the DMR11-A on the Unibus. IN-PLANT EFFECTIVITY: Feb 83 FIELD EFFECTIVITY: Re-arrange Module Utilization. Refer to the following configurations: #1. Basic DN200 drawer fully expanded. #2. Basic DN200 drawer fully expanded special configuration with LP20. #3. Basic DN200 drawer fully expanded special configuration with DN20-BA. #4. Maximium System expansion with no special configuration. QUICK CHECK: Check the Module Utilization and compare configurations per instructions in the FCO. The DEC on-site labor charge will be the time required to install and test the FCO at the then current hourly rate. FCO KIT ORDERING: FA-04548-01: FCO only