_ DEC-O-LOG for DNSBX_O001 _ DOL, DNSBX-O001, Potential for short in transformer FEB 94 APPLICABILITY: This is an "O" coded FCO and it should be installed on all DECnis 600 platforms: DNSBX-AD, DNSBA-BC/BD, DNSEA-BC/BD, DNSEB-BC/BD, DNSEC-BC/BD, DNSED-BC/BD, DNSEE-BC/BD, DNSEF-EE/BD, DNSBB-BC/BD, DNSBD-BC/BD. This FCO will replace the H7720-AA (30-36324-01) with revision "C01". PROBLEM & SYMPTOM: Under certain failure modes, there are indications for a potential cause of an electrical short in the transformer. This could re sult in the power supply overheating. The symptom is an unexpected failure of the device due to loss of power. This may be accompanied by release of smoke. This is not a safety hazard. SOLUTION: The solution for this problem is to re place every power supply H7720-AA below revision C01 with revision C01 or higher. However, because the DECNIS 600 is a key high-end networking prod uct, FCO implementation will need to be scheduled in advance with customers. The customer and Field Service will need to agree and schedule a "non-critical" time to have the PSU replaced. QUICK CHECK: All good and fully tested PSUs will be at revision C01 or higher. All "suspect" PSUs will be at lower revisions; either A01, B01, B02 or B03. The revision number is situated immediately under the AC input socket. FCO KIT ORDERING: EQ-01683-01 30-36324-01 Power Supply, Rev C01 FA-05020-01 FIELD APPLICATION (FA) DOC