_ DEC-O-LOG for DW780 _ DOL, DW780-S00C1, VAX 11780 & 11785 Systems MAR 85 PROBLEM: Unibus time-outs occur on devices that use buffer data paths. IN-PLANT EFFECTIVITY: DEC 84 FIELD EFFECTIVITY: All 11780 & 11785 Systems that exhibit Unibus Timeout Errors due to a Prefetch Read Command Error or use Buffer Data Paths in the DW780 need this FCO. The minimum acceptable revision of modules in spares stock is as follows: M8271-Etch Rev. "A", Part Rev. "F1" and M8271-Etch Rev. "B", Part Rev. "F2". QUICK CHECK: Presence of 74S74 at location E118. The DEC on-site labor charge will be the time required to install and test the FCO at the then current hourly rate. FCO KIT ORDERING: EQ-01339-01: FCO, PARTS FA-04620-01: FCO only