_ DEC-O-LOG for KA650 _ DOL, KA650-F001, CPU JUL 89 PROBLEM: 1)Failure of the above mentioned systems to autoboot a RA70 during power-up or after a power failure/power-up sequence. 2)Ultrix 3.0 upgrade incompatible with earlier revisions of the CPU. 3)Failure of the system to autoboot a RA90 during power-up or after a dismount. 4)Technical points 1, 2 and 3 of Customer Letter dealing with DMA transfers, POLY instructions and non-Digital device drives. 5)Support of DSSI technology for older revisions of CPU board (Rev B-F). 6)Support of KXJ11 Option. FIELD EFFECTIVITY: MicroVAX 3600, MicroVAX 3500, VAXstation 3200 and VAXstation 3500 which are experiencing the symptoms described below. QUICK CHECK: Upon boot,the following banner should be displayed: KA650-A/B V5.3 V2.7 (or higher) or check rev. of CPU module which will be at rev. K2 or higher. FCO KIT ORDERING: EQ-01550-01 (KA650-AA) EQ-01550-02 (KA650-BA) FA-04855-01 FA Document