_ DEC-O-LOG for KDA50 _ DOL, KDA50-I001, DISK CONTROLLER APR 86 PROBLEM: Correctable ECC errors in the last block of a read operation does not report "SUCCESS" in the end packet, resulting in an improper "FORCED ERROR" indication. FIELD EFFECTIVITY: Retrofit all KDA50-Q M7164 Revision "C6" and below. This will change the M7164 Micro Processor Module to the following Revisions: For "B" etch revision -- "D1"; for "C" etch revision -- "D2." NOTE: This FCO incorporates ECO #M7164-CX005. The KDA50 top level revision will be changed to "D1." QUICK CHECK: If E101-E106 contain the following PROMs: 23-078F6, 23-079F6, 23-080F6, 23-081F6, 23-082F6, 23-083F6, this FCO is required. This revised FCO supersedes the original release dated 4 March 1986. It has been revised to reflect a change in the LARS form. FCO KIT ORDERING: EQ-01307-01 FCO, PARTS FA-04586-01 FCO only