_ DEC-O-LOG for RP07 _ DOL, RP07-S0039, RP07 Disk Drive MAY 84 PROBLEM: Presence of Hard and Soft Data Pattern related read errors. CORRECTION: Update the RP07 documentation to reflect all the changes that have been made to the Drive. IN-PLANT EFFECTIVITY: May 83 FIELD EFFECTIVITY: Retrofit the following RP07 Drives when the Problem/Symptoms are evident: SERIAL NUMBERS CX101-104, CX107, CX109, CX110, CX126-128, CX131 CX133, CX135, CX138, CX141, CX145-149, CX152-155 CX157-170, CX172-190, CX192-200, CX202-207 CX209-211, CX213-216, CX218-273, CX275-591 CX593-605, CX607-641, CX643-657, CX659-664 CX667, CX670-671, CX673, CX676-678 CX684, CX688, CX690, CX706, CX718, CX720 CX724, CX726, CX729-4252 QUICK CHECK: Presence of the A1A15 as the B9706392-06. The DEC on-site labor charge will be the time required to install and test the FCO at the then current hourly rate. FCO KIT ORDERING: EQ-04506-01: FCO, PARTS FA-01240-01: FCO only _ DOL, RP07-I040, RP07 Disk Drive, APR 87 PROBLEM: IF a Massbus Initialize is issued from the Controller, and the RP07 is doing a "SEEK", the Position in Progress (PIP) hangs. Also, a "Keep Alive Cease" problem is exhibited when running the RP07's Internal Diagnostics. If the RP07 is Spun down and Spun back up it, can occasionally issue an "Attention" to the Controller. FIELD EFFECTIVITY: Rework RP07 Drives for all DEC SYSTEM 10/20's. This FCO implements ECO RP07-CX040. QUICK CHECK: A1A7 Revision -09; A1A9 Revision -200; A1A10 Revision -300. If label on drive has a Rev level sticker below 70, then this FCO applies. This revised FCO supersedes the original release dated 16 Feb 1987. It has been revised to correct the Rev levels of A1A7, A1A9, A1A10, in the NOTE section on page 2 of the document. FCO KIT ORDERING: EQ-01414-01 FCO, PARTS EQ-01414-02 FCO, PARTS FA-04699-01 FCO only _ DOL, RP07-I041, Disk AUG 86 PROBLEM: Improper Write Current Amplitude for new "G" type media. Increase Write Current needed when installing new HDA with "G" type media. Implementing this FCO without "G" type media will increase reliability of the HDA and prepare the Drive for future use of the "G" type media. FIELD EFFECTIVITY: Retrofit all RP07's with 348 Ohm 1/4 Watt resistors. This FCO implements ECO #RP07-CXO. QUICK CHECK: A1A16 Read/Write Safety Module at revision "105" for PCA number B9706402 and revision "02" for PCA number B9706632. FCO KIT ORDERING: EQ-01426-01 FCO, PARTS FA-04711-01 FCO only