_ DEC-O-LOG for TA81 _ DOL, TA81-I001, STI Controller Module OCT 86 PROBLEM: "blocks Lost" or "postion Lost" error on Backup/Verify operation during VMS Backup. Acknowledge not set at start of transfer. FIELD EFFECTIVITY: Rework all TA81 Transports with STI Controller Modules at (Vendor) P/N 77042145 and below. All TA81 Option Revision Level A1, B1, and C1. This FCO incorporates ECO's TA81-SH002 and TA81-SH003. QUICK CHECK: ROM in location G2 on STI Interface board at STI0908-1 P/N 77028485. FCO KIT ORDERING: EQ-01443-01 FCO, PARTS FA-04729-01 FCO only _ DOL, TA81-F002, TA81 Tape Drives, DEC 91 TA81-F002 DEC 91 - PROBLEM: When performing a backup operation, the customer can experience in- termittent position lost errors or serious exception errors. Position lost errors can be determined in errorlog by status event code of 11, serious exception errors can be identified by status event code of 12. A failure to write or retry a tape mark will be identified in the errorlog extended sense data info as a write tape mark check error, byte 9 of the extended sense data will in- dicate status of 08. FIELD EFFECTIVITY: This FCO applies to TA81 tape drives that experience position lost errors or serious exception errors caused by a failure to write or tetry written tape marks while performing a backup operation. SOLUTION: Replace the STI interface module (29-25345-00) below revision D01. QUICK CHECK: Rev. D01 and below do not feature the microcode changes. The DEC on-site labor charge will be the time required to install and test the FCO at the then current hourly rate. FCO KIT ORDERING EQ-01626-02 Interface Module FA-04960-02 FCO Document