_ DEC-O-LOG for TSV05 _ DOL, TSV05-I002, Magtape Subsystems, MAR 90 PROBLEM: The TSV05-Sx MagTape subsystem does not provide optimum performance on MicroVAX 3300 and later systems due to a change in the way these systems handle data transfers on the QBUS. FIELD EFFECTIVITY:This FCO applies to all TSV05-Sx (-SA thru -SN) subsystems configured on MicroVAX 3300 and later CPU's. QUICK CHECK: Chceck the controller module in the CDkit. The upgraded kit contains a M7530-PA module. The non-upgraded kit, a M7206-PA module. FCO KIT ORDERING: EQ-01557-02 FCO, Parts FA-04867-02 FCO Document (European version also available)