_ DEC-O-LOG for TU81 _ DOL, TU81-M0001, TU81 Gass Springs MAY 85 PROBLEM: The top cover will not remain open and may slam shut unless opened beyond the 90 degree point. IN-PLANT EFFECTIVITY: DEC 84 FIELD EFFECTIVITY: Rework all TU81's that currently have gas springs involved. QUICK CHECK: Open the top cover of the TU81 and not the presence of the counter balance assembly instead of gas springs. The DEC on-site labor charge will be the time required to install and test the FCO at the then current hourly rate. FCO KIT ORDERING: EQ-01342-01: FCO, PARTS FA-04623-01: FCO only _ DOL, TU81-I-002, TU81 Gas Springs JUN 85 IN-PLANT EFFECTIVITY: JUN 85 PROBLEM: Error code 72 is displayed when running the Operator Test "01" with a non Write Protected Tape. FIELD EFFECTIVITY: Rework all TU81 Transports to Vendor Serial Number 6648. QUICK CHECK: Perform the Operator Test "01" with a tape and without a Write Ring installed. The DEC on-site labor charge will be the time required to install and test the FCO at the then current hourly rate. FCO KIT ORDERING: EQ-01383-01: FCO, PARTS FA-04665-01: FCO only _ DOL, TU81-R003, TU81 JUL 85 PROBLEM: Parity Errors (ARA Burst Failures) when Initializing Tapes in the GCR mode. FIELD EFFECTIVITY: Rework all TU81 Tranports to Vendor Serial Number 6648. QUICK CHECK: Presence of ROM (P/N 77-02845-00) in location D-3 on the Read Formatter Module. The DEC on-site labor charge will be the time required to install and test the FCO at the then current hourly rate. FCO KIT ORDERING: EQ-01384-01: FCO, PARTS FA-04666-01: FCO only _ DOL, TU81-I004, TAPE DRIVE MAR 87 PROBLEM: Error Code "63" on power up. Intermittent Controller fault light during normal operation. FIELD EFFECTIVITY: Rework all TU81/TA81 Transports when problem symptoms are evident. Option TU81 Rev C1, TU81E Rev B1 and TA81 Rev B1 and below. Formatter Write Modules P/N 77025981 and below. This FCO implements ECO TU81-SH009. QUICK CHECK: Clamp between formatter Write and Read Modules. FCO KIT ORDERING: EQ-01464-01 FCO, PARTS FA-04750-01 FCO only _ DOL, TU81-R005, TAPE DRIVE NOV 87 PROBLEM: BACKUP-E-BLOCKLOST Error under VMS Backup BACKUP-I-HDRCRC Error under VMS Backup BACKUP-I-XOERRS Error under VMS Backup FIELD EFFECTIVITY: Rework all TU81 Transports on 11780-82, 11785 and 8600/8650 systems when problem/symptoms are evident. TU81 Rev. C1 and below. TMSCP Modules at Part Number 77041258 and below. NOTE: (NOT APPLICABLE FOR TU81E). QUICK CHECK: ROM in location G3 on TMSCP Module is P/N 77025244. FCO KIT ORDERING: EQ-01492-01 FCO, PARTS FA-04785-01 FCO only