VAX 4000 Model 200 Technical Information Order Number EK-396AB-TM-002 Digital Equipment Corporation Maynard, Massachusetts ------------------------------------------------------------ First Printing, December 1990 Revised, June 1991 The information in this document is subject to change without notice and should not be construed as a commitment by Digital Equipment Corporation. Digital Equipment Corporation assumes no responsibility for any errors that may appear in this document. The software, if any, described in this document is furnished under a license and may be used or copied only in accordance with the terms of such license. No responsibility is assumed for the use or reliability of software or equipment that is not supplied by Digital Equipment Corporation or its affiliated companies. Restricted Rights: Use, duplication or disclosure by the U.S. Government is subject to restrictions as set forth in subparagraph (c)(1)(ii) of the Rights in Technical Data and Computer Software clause at DFARS 252.227-7013. ©Digital Equipment Corporation, 1990, 1991. All rights reserved. Printed in U.S.A. The Reader 's Comments form at the end of this document requests your critical evaluation to assist in preparing future documentation. The following are trademarks of Digital Equipment Corporation: CompacTape, CX, DDCMP, DEC, DECconnect, DECdirect, DECnet, DECscan, DECserver, DECUS, DECwindows, DELNI, DEMPR, DESQA, DESTA, DSRVB, DSSI, IVAX, KDA, KLESI, MicroVAX, MSCP, Q-bus, Q22-bus, RA, RQDX, RV20, SA, SDI, ThinWire, TK, TMSCP, TQK, TS05, TU, VAX, VAX 4000, VAXcluster, VAX DOCUMENT, VAXELN, VAXlab, VAXserver, VMS, VT, and the DIGITAL logo. Amphenol is a trademark of Amphenol Corporation. Bell is a trademark of Bell telephone companies. CHAMP is a registered trademark of AMP Inc. IBM is a trademark of International Business Machines Corporation. FCC NOTICE: The equipment described in this manual generates, uses, and may emit radio frequency energy. The equipment has been type tested and found to comply with the limits for a Class A computing device pursuant to Subpart J of Part 15 of FCC Rules, which are designed to provide reasonable protection against such radio frequency interference when operated in a commercial environment. Operation of this equipment in a residential area may cause interference, in which case the user at his own expense may be required to take measures to correct the interference. S1686 This document was prepared using VAX DOCUMENT, Version 1.2. Contents ------------------------------------------------------------ Preface vii ------------------------------------------------------------ Chapter 1 Base System Description ------------------------------------------------------------ 1.1 System Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-1 1.2 Firmware Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-3 1.3 Power-Up . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-4 1.4 Console I/O Mode Overview . . . . . . . . . . . . . . . . . . . . . . . . . . 1-4 1.4.1 Control Characters in Console I/O Mode . . . . . . . . . . . . . . 1-4 1.4.2 Console I/O Mode Commands . . . . . . . . . . . . . . . . . . . . . . . 1-6 1.5 Digital Storage Systems Interconnect (DSSI) . . . . . . . . . . . . . 1-14 1.6 KA660-AA-BA CPU Specifications . . . . . . . . . . . . . . . . . . . . . 1-15 Chapter 2 Option Specifications ------------------------------------------------------------ 2.1 Options Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-2 2.1.1 Configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-2 2.2 Mass Storage Options . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-3 2.2.1 KDA50 Controller . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-4 2.2.2 KFQSA Storage Adapter . . . . . . . . . . . . . . . . . . . . . . . . . . 2-5 2.2.3 KLESI Controller . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-6 2.2.4 KZQSA Storage Adapter . . . . . . . . . . . . . . . . . . . . . . . . . . 2-7 2.2.5 RA60 Disk Drive . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-8 2.2.6 RA70E Disk Drive . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-9 2.2.7 RA81 Disk Drive . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-10 2.2.8 RA82 Disk Drive . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-11 2.2.9 RA90 Disk Drive . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-12 2.2.10 RA92 Disk Drive . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-13 2.2.11 RF31 Integrated Storage Element (ISE) . . . . . . . . . . . . . . 2-14 2.2.12 RF31F Integrated Storage Element . . . . . . . . . . . . . . . . . . 2-15 iii 2.2.13 RF71 Integrated Storage Element (ISE) . . . . . . . . . . . . . . 2-17 2.2.14 RF72 Integrated Storage Element (ISE) . . . . . . . . . . . . . . 2-18 2.2.15 RRD40 Compact-Disc Subsystem . . . . . . . . . . . . . . . . . . . . 2-20 2.2.16 RRD42 Optical Compact-Disc Subsystem . . . . . . . . . . . . . . 2-21 2.2.17 TF85 Tape Drive . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-23 2.2.18 TK50 Tape Drive . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-25 2.2.19 TK70 Tape Drive . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-27 2.2.20 TLZ04 Tape Drive . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-29 2.2.21 TQK70 Controller . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-31 2.2.22 TSZ07 Tape Drive . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-32 2.2.23 TSV05 Tape Drive . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-34 2.2.24 TSV05 Controller . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-35 2.2.25 TU81-Plus Tape Drive . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-36 2.3 Communications Options . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-38 2.3.1 CXA16 Asynchronous Multiplexer (16 lines) . . . . . . . . . . . 2-39 2.3.2 CXB16 Asynchronous Multiplexer (16 lines) . . . . . . . . . . . 2-42 2.3.3 CXY08 Asynchronous Multiplexer (8 Lines) . . . . . . . . . . . . 2-45 2.3.4 DESQA Ethernet Controller . . . . . . . . . . . . . . . . . . . . . . . 2-47 2.3.5 DEQRA Token Ring Q-bus Adapter . . . . . . . . . . . . . . . . . . 2-48 2.3.6 DFA01 Asynchronous Controller with Integral Modem . . . 2-50 2.3.7 DPV11 Synchronous Controller . . . . . . . . . . . . . . . . . . . . . 2-52 2.3.8 DSRVB DECserver 200 . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-53 2.3.9 DSV11 Synchronous Controller . . . . . . . . . . . . . . . . . . . . . 2-55 2.4 Real-Time Options . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-56 2.4.1 AAV11-S Digital-to-Analog Converter . . . . . . . . . . . . . . . . 2-57 2.4.2 ADQ32 Analog-to-Digital Converter . . . . . . . . . . . . . . . . . . 2-59 2.4.3 ADV11-S Analog-to-Digital Converter . . . . . . . . . . . . . . . . 2-61 2.4.4 AXV11 Controller . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-63 2.4.5 DIV32 Controller . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-65 2.4.6 DRQ3B Parallel Interface . . . . . . . . . . . . . . . . . . . . . . . . . 2-66 2.4.7 DRV1W Parallel Interface . . . . . . . . . . . . . . . . . . . . . . . . . 2-67 2.4.8 IBQ01 Controller . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-69 2.4.9 IEQ11 Controller . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-70 2.4.10 KWV11-S Programmable Real-Time Clock . . . . . . . . . . . . 2-71 2.5 Printer Interface . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-73 2.5.1 LPV11-SA Printer Interface . . . . . . . . . . . . . . . . . . . . . . . 2-73 iv 2.6 Graphics Adapters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-74 2.6.1 VS30U Graphics Adapter . . . . . . . . . . . . . . . . . . . . . . . . . . 2-74 Chapter 3 System Expansion ------------------------------------------------------------ 3.1 Planning System Expansion . . . . . . . . . . . . . . . . . . . . . . . . . . 3-1 3.2 Completing the VAX 4000 Model 200 Configuration Worksheets . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-2 Index ------------------------------------------------------------ Examples ------------------------------------------------------------ 1-1 SHOW QBUS Display . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-9 1-2 SHOW DEVICE Display . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-11 1-3 SHOW ETHERNET Display . . . . . . . . . . . . . . . . . . . . . . . . . 1-11 1-4 SHOW LANGUAGE Display . . . . . . . . . . . . . . . . . . . . . . . . . 1-12 1-5 SET LANGUAGE Command . . . . . . . . . . . . . . . . . . . . . . . . . 1-12 1-6 SET BOOT Command . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-12 Figures ------------------------------------------------------------ 1-1 VAX 4000 Model 200 Block Diagram . . . . . . . . . . . . . . . . . . . 1-2 3-1 VAX 4000 Model 200 (BA430 Enclosure) Configuration Worksheet . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-3 3-2 VAX 4000 Model 200 (BA215 Enclosure) Configuration Worksheet . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-4 Tables ------------------------------------------------------------ 1-1 Console I/O Mode Control Characters . . . . . . . . . . . . . . . . . . 1-5 1-2 Console I/O Mode Commands . . . . . . . . . . . . . . . . . . . . . . . . . 1-7 1-3 Boot Device Names . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-13 3-1 Power Requirements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-5 v Preface ------------------------------------------------------------ This manual provides a summary of technical information about the VAX 4000 Model 200 system. · Chapter 1 describes the base system and lists specifications for the KA660-AA/-BA CPU module and MS650-BA/-BB memory module. · Chapter 2 describes optional components available for your system and lists their specifications. · Chapter 3 contains information on expanding your system. NOTE: You will find a glossary in the VAX 4000 Model 200 Operation manual to help with word definitions and acronyms. Conventions The following conventions are used in this manual: ------------------------------------------------------------ Convention Meaning ------------------------------------------------------------ ------------------------------------------------------------ ------------------------------------------------------------ Return ------------------------------------------------------------ ------------------------------------------------------------ A key name is shown enclosed to indicate that you press a named key on the keyboard. ------------------------------------------------------------ ------------------------------------------------------------ Ctrl/x ------------------------------------------------------------ ------------------------------------------------------------ A sequence such as ------------------------------------------------------------ ------------------------------------------------------------ Ctrl/x ------------------------------------------------------------ ------------------------------------------------------------ indicates that you must hold down the key labeled Ctrl while you press another key. BOLD This bold type indicates user input. For example: >>> BOOT MUA0 The user must enter BOOT MUA0 at the console prompt. NOTE Notes provide general information about the current topic. CAUTION Information to prevent damage to equipment or software. WARNING Information to prevent personal injury. ------------------------------------------------------------ vii Chapter 1 Base System Description ------------------------------------------------------------ This chapter describes the VAX 4000 Model 200 base system, including the following: · Power-up self tests · Digital Storage Systems Interconnect (DSSI) architecture · Specifications for the KA660-AA/BA CPU and MS650-BA/BB memory 1.1 System Overview The VAX 4000 Model 200 base system components are housed in two different enclosures: the BA430 enclosure, which contains a 12-slot Q- bus backplane, and the BA215 enclosure, which contains a 6-slot Q-bus backplane. Each base system contains the following: · A KA660-AA/BA (M7626-A/-B) central processing unit (CPU) module · From one to four MS650-Bx memory modules. The base system modules are located in the following card slots: · MS650-Bx memory modules are installed in slots 2 through 5. · The KA660 CPU module is installed in slot 1. The base system operates from the KA660 CPU firmware and the controls on the CPU cover panel. The firmware is described in Section 1.2. Base system operation also integrates Digital Storage Systems Interconnect (DSSI) technology, which is discussed in Section 1.5. Figure 1-1 is a block diagram of the VAX 4000 Model 200 system. Base System Description 1-1 Figure 1-1: VAX 4000 Model 200 Block Diagram 1-2 VAX 4000 Model 200 Technical Information 1.2 Firmware Overview Two electrically programmable read-only memory (EPROM) chips on the KA660 CPU module contain the firmware. This firmware consists of the following three major programs, which perform the system power-up self- tests and diagnostics: · A console program · A set of self-tests for the CPU and memory · A primary bootstrap program (VMB) The console program receives control whenever the processor halts. In a processor halt, processor control passes to the console program and instruction execution continues. The standard VAX console functionality is emulated whenever you execute a program in ROM. Control passes to the firmware under any of the following conditions: · You turn on the system. · You press the Restart button. · You assert the Q22-bus BHALT signal by pressing the Halt button. · You enter a break when the Break Enable/Disable switch is set to enable. · A HALT instruction is executed. · A fatal system error occurs. Base System Description 1-3 1.3 Power-Up At power-up, the console program determines the console device type and console language, then runs the self-tests for the CPU and memory. You choose the console language when you perform the set-up operations during your console terminal installation procedure. You determine the type of power-up mode by setting the Power-Up Mode switch on the CPU cover panel. See your VAX 4000 Model 200 Operation manual for the following power-up information: · Power-up procedures · Power-Up Mode and Break Enable/Disable switch settings · Examples of successful power-up sequences · Boot and autoboot procedures See the VAX 4000 Model 200 Troubleshooting and Diagnostics manual for examples of problems you may encounter during power-up. 1.4 Console I/O Mode Overview If you set the Break Enable/Disable switch on the CPU cover panel to enable, the console program enters Console I/O mode after the power- up self-tests are completed successfully. The console program also enters Console I/O mode in response to any external halt condition. CAUTION: Do not press the Restart button while the console program is in console mode. Doing so destroys the system state and prevents normal operation. Console I/O mode allows you to control the system by entering commands at the console prompt >>>. You may enter these commands in either uppercase or lowercase letters. Enter each command, then press ------------------------------------------------------------ ------------------------------------------------------------ Return ------------------------------------------------------------ ------------------------------------------------------------ . 1.4.1 Control Characters in Console I/O Mode Table 1-1 lists the keypad control characters that have special meaning in Console I/O mode. 1-4 VAX 4000 Model 200 Technical Information Table 1-1: Console I/O Mode Control Characters ------------------------------------------------------------ Character Action ------------------------------------------------------------ ------------------------------------------------------------ ------------------------------------------------------------ Return ------------------------------------------------------------ ------------------------------------------------------------ also The carriage return ends a command line. No action is taken on a command until after it is terminated by a carriage return. A null line terminated by a carriage return is treated as a valid, null command. No action is taken, and the console prompts for input. Carriage return is echoed as carriage return, line feed (). ------------------------------------------------------------ ------------------------------------------------------------ X ------------------------------------------------------------ ------------------------------------------------------------ (rubout) When you press ------------------------------------------------------------ ------------------------------------------------------------ x ------------------------------------------------------------ ------------------------------------------------------------ (rubout), the console deletes the previously typed character. The resulting display differs, depending on whether the console is a video or a hardcopy terminal. For hardcopy terminals, the console echoes a backslash (\ ) followed by the character being deleted. If you press additional rubouts, the additional deleted characters are echoed. If you type a non-rubout character, the console echoes another backslash, followed by the character typed. The result is to echo the characters deleted, surrounding them with backslashes. For example: EXAMI;E ------------------------------------------------------------ ------------------------------------------------------------ X ------------------------------------------------------------ ------------------------------------------------------------ ------------------------------------------------------------ ------------------------------------------------------------ X ------------------------------------------------------------ ------------------------------------------------------------ NE The console echoes: EXAMI;E\ E\ NE The console sees the command line: EXAMINE For video terminals, the previous character is erased and the cursor is restored to its previous position. The console does not delete characters past the beginning of a command line. If you press more rubouts than there are characters on the line, the extra rubouts are ignored. A rubout entered on a blank line is ignored. ------------------------------------------------------------ ------------------------------------------------------------ Ctrl/A ------------------------------------------------------------ ------------------------------------------------------------ or ------------------------------------------------------------ ------------------------------------------------------------ F14 ------------------------------------------------------------ ------------------------------------------------------------ Toggles insertion/overstrike mode for command line editing. By default, the console powers up to overstrike mode. ------------------------------------------------------------ ------------------------------------------------------------ Ctrl/C ------------------------------------------------------------ ------------------------------------------------------------ Echoes ^C and aborts processing of a command. Has no effect as part of a binary load data stream. Clears ------------------------------------------------------------ ------------------------------------------------------------ Ctrl/S ------------------------------------------------------------ ------------------------------------------------------------ and re-enables output stopped by ------------------------------------------------------------ ------------------------------------------------------------ Ctrl/O ------------------------------------------------------------ ------------------------------------------------------------ . ------------------------------------------------------------ ------------------------------------------------------------ Ctrl/D ------------------------------------------------------------ ------------------------------------------------------------ or ------------------------------------------------------------ ------------------------------------------------------------ ------------------------------------------------------------ ------------------------------------------------------------ Moves the cursor one position to the left. ------------------------------------------------------------ ------------------------------------------------------------ Ctrl/E ------------------------------------------------------------ ------------------------------------------------------------ Moves the cursor to the end of the line. ------------------------------------------------------------ ------------------------------------------------------------ Ctrl/F ------------------------------------------------------------ ------------------------------------------------------------ or ------------------------------------------------------------ ------------------------------------------------------------ ! ------------------------------------------------------------ ------------------------------------------------------------ Moves the cursor one position to the right. ------------------------------------------------------------ ------------------------------------------------------------ Ctrl/B ------------------------------------------------------------ ------------------------------------------------------------ , ------------------------------------------------------------ ------------------------------------------------------------ " ------------------------------------------------------------ ------------------------------------------------------------ , or ------------------------------------------------------------ ------------------------------------------------------------ # ------------------------------------------------------------ ------------------------------------------------------------ Recalls the previous commands. ------------------------------------------------------------ ------------------------------------------------------------ Ctrl/H ------------------------------------------------------------ ------------------------------------------------------------ , ------------------------------------------------------------ ------------------------------------------------------------ X ------------------------------------------------------------ ------------------------------------------------------------ (rubout), or ------------------------------------------------------------ ------------------------------------------------------------ F12 ------------------------------------------------------------ ------------------------------------------------------------ Deletes the previously typed character. Same function as ------------------------------------------------------------ ------------------------------------------------------------ X ------------------------------------------------------------ ------------------------------------------------------------ (rubout), above. ------------------------------------------------------------ ------------------------------------------------------------ Ctrl/O ------------------------------------------------------------ ------------------------------------------------------------ Ignores transmissions to the console until you enter ------------------------------------------------------------ ------------------------------------------------------------ Ctrl/O ------------------------------------------------------------ ------------------------------------------------------------ . Echoes ^O when disabling output, which is not echoed when it re-enables output. Output is re-enabled if the console prints an error message, or if it prompts for a command from the terminal. Output is also enabled by entering Maintenance mode: press ------------------------------------------------------------ ------------------------------------------------------------ Break ------------------------------------------------------------ ------------------------------------------------------------ or enter ------------------------------------------------------------ ------------------------------------------------------------ Ctrl/C ------------------------------------------------------------ ------------------------------------------------------------ . ------------------------------------------------------------ ------------------------------------------------------------ Ctrl/Q ------------------------------------------------------------ ------------------------------------------------------------ Resumes output to the console terminal. Not echoed. Base System Description 1-5 Table 1-1 (Cont.): Console I/O Mode Control Characters ------------------------------------------------------------ Character Action ------------------------------------------------------------ ------------------------------------------------------------ ------------------------------------------------------------ Ctrl/R ------------------------------------------------------------ ------------------------------------------------------------ Echoes , followed by the current command line. Can be used to improve the readability of a command line that has been heavily edited. ------------------------------------------------------------ ------------------------------------------------------------ Ctrl/S ------------------------------------------------------------ ------------------------------------------------------------ Stops output to the console terminal until you enter ------------------------------------------------------------ ------------------------------------------------------------ Ctrl/Q ------------------------------------------------------------ ------------------------------------------------------------ . Not echoed. ------------------------------------------------------------ ------------------------------------------------------------ Ctrl/U ------------------------------------------------------------ ------------------------------------------------------------ Echoes ^U. Entered, but otherwise ignored if typed on an empty line. ------------------------------------------------------------ The console accepts Console I/O mode commands up to 80 characters long. Longer commands produce error messages. The character count does not include rubouts, rubbed-out characters, or the at the end of the command. Two or more consecutive spaces and tabs are treated as a single space. Leading and trailing spaces and tabs are ignored. You can place command qualifiers after the command keyword or after any symbol or number in the command. All numbers (addresses, data, counts) are hexadecimal, but symbolic register names contain decimal register numbers. The hexadecimal digits are 0 through 9 and A through F. You can use uppercase and lowercase letters in hexadecimal numbers (A through F) and commands. The following symbols are qualifier and argument conventions: [ ] = an optional qualifier or argument {} = a required qualifier or argument 1.4.2 Console I/O Mode Commands Table 1-2 lists and describes the I/O mode commands. You can display the list of commands by entering HELP at the console prompt (>>>). For a complete explanation of how to use the commands, along with information on qualifiers and arguments, refer to the KA660 CPU Technical Manual (EK-KA660-TM). 1-6 VAX 4000 Model 200 Technical Information Table 1-2: Console I/O Mode Commands ------------------------------------------------------------ Command Action ------------------------------------------------------------ BOOT Initializes the processor and transfers execution to the VMB. CONFIGURE Invokes an interactive mode that permits you to enter Q22-bus device names, then generates a table of Q22-bus I/O page device CSR addresses and interrupt vectors. CONTINUE Causes the processor to begin instruction execution at the address currently contained in the program counter (PC). Does not perform a processor initialization. DEPOSIT Deposits data into the address you specify. If you do not specify an address space or data size qualifier, the console uses the last address space and data size used in a DEPOSIT, EXAMINE, MOVE, or SEARCH command. EXAMINE Examines the contents of the memory location or register of the address you specify. If you do not specify an address, + is assumed. FIND Searches main memory starting at address 0 (zero) for a page- aligned 128-Kbyte segment of good memory, or a restart parameter block (RPB). HALT The HALT command has no effect. It is included for compatibility with other VAX consoles. HELP Displays the correct syntax for all console commands. INITIALIZE Performs a processor initialization. MOVE Copies the block of memory starting at the source address to a block beginning at the destination address. NEXT Executes the number of macro instructions you specify. If you do not specify a number, 1 (one) is assumed. REPEAT Repeatedly displays and executes the command you specify. Press ------------------------------------------------------------ ------------------------------------------------------------ Ctrl/C ------------------------------------------------------------ ------------------------------------------------------------ to stop the command. You can specify any valid console command except the REPEAT command. SEARCH Finds all occurrences of a pattern and reports the addresses where the pattern was found. If you include the /NOT qualifier, the command reports all addresses for which the pattern did not match. SET BFLAG Sets the default R5 boot flags. The value must be a hexadecimal number of up to eight digits. SET BOOT Sets the default boot device. The value must be a valid device name. SET CONTROLP Sets Control-P as the console halt condition, instead of a BREAK. SET HOST Connects to the DUP or MAINTENANCE driver on the node or device you specify. SET LANGUAGE Sets the console language and keyboard type. SET HALT Sets the halt action you define. Acceptable values are the following keywords: default, restart, reboot, halt, restart_reboot, or a number in the range 0 to 4 inclusive. Base System Description 1-7 Table 1-2 (Cont.): Console I/O Mode Commands ------------------------------------------------------------ Command Action ------------------------------------------------------------ SET RECALL Sets command recall state to either ENABLED (1) or DISABLED (0). SHOW BFLAG Displays the default R5 boot flags. SHOW BOOT Displays the default boot device. SHOW CONTROLP Shows the current state of Control-P halt recognition, either ENABLED or DISABLED. SHOW DEVICE Displays all devices displayed by the SHOW DSSI, SHOW ETHERNET, and SHOW UQSSP commands. SHOW DSSI Displays the status of all nodes that can be found on the DSSI bus. For each node on the DSSI bus, the firmware displays the node number, the node name, and the boot name and type of the device, if available. Does not indicate whether the device contains a bootable image. SHOW ETHERNET Displays the hardware Ethernet address for all Ethernet adapters that can be found, both on-board and on the Q22-bus. SHOW LANGUAGE Displays console language and keyboard type. SHOW MEMORY Displays main memory configuration, board by board. SHOW QBUS Displays all Q22-bus I/O addresses that respond to an aligned word read, plus vector and device name information. For each address, the console displays the address in the VAX I/O space in hexadecimal, the address as it would appear in the Q22-bus I/O space in octal, and the word that was read in hexadecimal. Also displays the vector that you should set up, and device name or names that could be associated with the CSR. SHOW RECALL Displays the current state of command recall, either ENABLED or DISABLED. SHOW HALT Displays the halt action. Keywords include: default, restart, reboot, halt, restart_reboot, or a number in the range 0 to 4 inclusive. SHOW RLV12 Displays all RL01 and RL02 disks that appear on the Q22-bus. SHOW TRANSLATION Shows any virtual addresses that map to the specified physical address. SHOW UQSSP Displays the status of all disks and tapes that can be found on the Q22-bus that support the UQSSP protocol. For each such disk or tape on the Q22-bus, the firmware displays the controller number, the controller CSR address, and the boot name and type of each device connected to the controller. The command does not indicate whether the device contains a bootable image. SHOW VERSION Displays the current firmware version. START Starts instruction execution at the address you specify. If you do not give an address, the current program counter is used. If memory mapping is enabled, macro instructions are executed from virtual memory, and the address is treated as a virtual address. Equivalent to a DEPOSIT to PC, followed by a CONTINUE. Does not perform a processor initialization. 1-8 VAX 4000 Model 200 Technical Information Table 1-2 (Cont.): Console I/O Mode Commands ------------------------------------------------------------ Command Action ------------------------------------------------------------ TEST Invokes a diagnostic test program specified by the test number you enter. If you enter a test number of 0 (zero), all tests allowed to be executed from the console terminal are executed. The console accepts an optional list of up to five additional hexadecimal arguments. UNJAM Performs an I/O bus reset, by writing a 1 (one) to IPR 55 (decimal). X Loads or unloads (that is, writes to memory or reads from memory) the specified number of data bytes through the console serial line (regardless of console type), starting at the specified address. For use by automatic systems communicating with the console. ------------------------------------------------------------ Examples 1-1 through 1-6 show sample displays for the commonly used commands SHOW and SET. The SET command sets the parameter to the value you specify. The SHOW command displays the console parameter you specify. Example 1-1: SHOW QBUS Display >>> SHOW QBUS Scan of QBUS I/O Space -200000DC (760334) = 0000 (300) TLZ04/TQK70/RRD40/RQC25/KFQSA-DISK -200000DE (760336) = 0AA0 -200000E0 (760340) = 0000 (304) TLZ04/TQK70/RRD40/RQC25/KFQSA-DISK -200000E2 (760342) = 0AA0 -200000E4 (760344) = 0000 (310) TLZ04/TQK70/RRD40/RQC25/KFQSA-DISK -200000E6 (760346) = 0AA0 -20001468 (772150) = 0000 (154) TLZ04/TQK70/RRD40/RQC25/KFQSA-DISK -2000146A (772152) = 0AA0 -20001F40 (777500) = 0020 (004) IPCR Example 1-1 (continued on next page) Base System Description 1-9 Example 1-1 (Cont.): SHOW QBUS Display Scan of QBUS Memory Space >>> -20000120 (760400) = 0080 (300) DHQ11/DHV11/CXA16/CXB16/CXY08 -20000122 (760442) = FO81 -20000124 (760444) = DD18 -20000126 (760446) = 0140 -20000128 (760450) = 0000 -2000012A (760452) = 0000 -2000012C (760454) = 8000 -2000012E (760456) = 0000 -200002C0 (761300) = 0000 (KZQSA) -200002C2 (761302) = 0000 -200002C4 (761304) = 0000 -200002C6 (761306) = 0000 -200002C8 (761310) = 0007 -200002CA (761312) = 0000 -200002CC (761314) = 0000 -200002CE (761320) = 0000 -200002D2 (761322 = 0000 -200002D4 (761324 = 0000 -200002D6 (761326 = 0000 -200002D8 (761330 = 0000 -200002DA (761332 = 0000 -200002DC (761334 = 0000 -200002DE (761336 = 0000 -200002E0 (761340 = 0000 -200002E2 (761342 = 0000 -200002E4 (761344 = 0000 -200002E6 (761346 = 0400 -200002E8 (761350 = 0000 -200002EA (761352 = 0000 -200002EC (761354 = 0000 -200002EE (761356 = 5049 -200002FO (761360 = 8420 -200002F2 (761362 = 0000 -200002F4 (761364 = 0100 -200002F6 (761366 = 0080 -200002F8 (761370 = 1E00 -200002FA (761372 = 032A -200002FC (761374 = 0000 -200002FE (761376 = 014C -20001940 (774500 = 0000 TKQ50/TQK70/TU81E/RV20/KFQSA--TAPE -20001942 (774502 = 0BC0 -20001F40 (777500 = 0000 Example 1-1 (continued on next page) 1-10 VAX 4000 Model 200 Technical Information Example 1-1 (Cont.): SHOW QBUS Display Scan of Qbus Memory Space -30040000 to 3005ffff (01000000 to 01377777) >>> For each address, the console displays the address in the VAX I/O space in hexadecimal, the address as it would appear in the Q22-bus I/O space in octal, and the word data that was read in hexadecimal. Example 1-2: SHOW DEVICE Display >>>SHOW DEVICE UQSSP Disk Controller 0 (772150) -DUA0 (RF71) UQSSP Disk Controller 1 (760334) -DUB1 (RF71) UQSSP Disk Controller 2 (760340) -DUC2 (RF71) UQSSP Tape Controller 0 (774500) -MUA0 (TK70) Ethernet Adapter 0 (774440) -XQA0 (08-00-2B-09-A3-96) UQSSP Tape Controller 0 (774500) -MUA0 (TK70) Ethernet Adapter -EZA0 (08-00-2B-06-10-42) For each device, the console displays the controller, the node, and the address on the first line, and the device name and option on the second line. Example 1-3: SHOW ETHERNET Display >>> SHOW ETHERNET Ethernet Adapter -EZA0 (08-00-2B-0B-29-14) Base System Description 1-11 Example 1-4: SHOW LANGUAGE Display >>> SHOW LANGUAGE English (United States/Canada) >>> Example 1-5: SET LANGUAGE Command >>> SET LANGUAGE 5 >>> Example 1-6: SET BOOT Command >>> SET BOOT MUA0 >>> In this example, selection 5 is English, chosen from the Language Selection Menu that displays at power-up. In this example, entering MUA0 sets the tape drive as the default boot device. Table 1-3 lists the supported device names. 1-12 VAX 4000 Model 200 Technical Information Table 1-3: Boot Device Names ------------------------------------------------------------ Device Type Controller/Adapter Device Logical Name ------------------------------------------------------------ RF-series ISE Embedded DSSI host adapter (part of CPU) DImn 1 RF-series ISE KFQSA storage adapter DUcn 2 TK-series tape drive TQK70/TQK50 MUcn 3 TF85 tape drive Embedded DSSI adapter MImu 1 TLZ-series tape drive KZQSA adapter MKAn RRD-series compact disc drive KZQSA adapter DKAn PROM (programmable read-only memory) MRV11 module PRAn Ethernet adapter On-board (part of CPU) EZA0 Ethernet adapter DESQA Ethernet controller XQAn RA-series drives KDA50 DUcn 2 ------------------------------------------------------------ 1 m = DSSI bus adapter (A = first bus (0), B = second bus (1), and so on.) n = unit number When under operating system control, DIBn devices are recognized as DIAn devices. 2 c = MSCP controller designator (A = first, B = second, and so on.) n = unit number 3 c = TMSCP controller designator (A = first, B = second, and so on.) n = unit number ------------------------------------------------------------ Base System Description 1-13 1.5 Digital Storage Systems Interconnect (DSSI) The KA660 CPU module contains an embedded DSSI chip on the module which becomes a DSSI bus interface connector that is dedicated to the mass storage devices in the VAX 4000 Model 200 system. (See Figure 1-1 for the VAX 4000 Model 200 block diagram.) The DSSI bus interface connects to a DSSI Integrated Storage Element (ISE). An ISE is a 5.25-inch disk drive that has special mounting brackets for simplified enclosure installation and upgrading. Each DSSI bus has the following characteristics: · A 4-Mbytes-per-second bandwidth · Up to eight nodes (one interface and up to seven ISEs) · Eight data lines · One parity line · Eight control lines DSSI architecture improves system performance as follows: · The DSSI bus handles all mass storage transactions. · Mass storage devices can act independently, since each device contains its own controller. Several devices can work simultaneously. The DSSI bus interface supports up to eight nodes. These eight nodes include the DSSI interface and seven ISEs. An ISE can maintain connections to more than one DSSI interface. In a dual-host configuration in which multiple CPUs can be connected to the DSSI bus interfaces. For example, two VAX 4000 Model 200 systems can have access to each ISE over a shared DSSI bus. For more information about using VAX 4000 Model 200 systems in a dual- host configuration, and the advantages of such configurations, see the VAX 4000 Model 200 Dual-Host Systems manual. 1-14 VAX 4000 Model 200 Technical Information 1.6 KA660-AA-BA CPU Specifications The VAX 4000 Model 200 system (in a BA430 enclosure and in a BA215 enclosure) uses the KA660-AA central processing unit. The VAXserver 4000 Model 200 (in a BA430 enclosure and in a BA215 enclosure) uses the KA660-BA central processing unit. ------------------------------------------------------------ Central Processing Unit ------------------------------------------------------------ Addressing modes General register: 8 Clock rate 114 MHz Data path width 64 bits Number of data types Hardware: 9 Software emulated: 7 Number of instructions Hardware: 272 Software emulated: 32 General purpose registers 16 (32-bit wide) Program counter: 4 Index: 9 PDP-11 compatibility mode Emulated in software Time bases Time-of-year clock: 1 (battery backup) Interval timer: 1 (10 milliseconds) Programmable timers: 2 I/O bus interface One Q22-bus interface with 8192 entry map Backplane termination 240 ------------------------------------------------------------ Memory Management and Control ------------------------------------------------------------ Page size 512 bytes Virtual address space 4 Gbytes Physical memory space 512 Mbytes Number of memory modules 4 maximum Base System Description 1-15 ------------------------------------------------------------ Performance ------------------------------------------------------------ Instruction prefetch buffer size 12 bytes On-chip cache Size 6 Kbytes Speed 28 nanoseconds Associativity Direct mapped Translation Buffer Size 64 entry Associativity Fully associative Q22-bus address translation map cache Size 12 entry Associativity Fully associative I/O bus buffer size Input 32 bytes Output 4 bytes Maximum I/O bandwidth Block mode DMA read 2.4 Mbytes/second Block mode DMA write 3.3 Mbytes/second ------------------------------------------------------------ Ethernet Port ------------------------------------------------------------ Supported protocols Ethernet V2.0 Supported media types Standard or ThinWire Data path width 1 bit Maximum bandwidth 10 Mbits/second Buffer size Transmit buffer 128 bytes/second Receiver buffer 128 bytes/second ------------------------------------------------------------ Digital Storage Systems Interconnect (DSSI) Connector ------------------------------------------------------------ Maximum number of supported devices 7 Data path width 8 bits Maximum bandwidth 4 Mbytes/second Maximum queue I/O 800/second Buffer size Transmit buffer 128 bytes/second Receiver buffer 128 bytes/second 1-16 VAX 4000 Model 200 Technical Information ------------------------------------------------------------ Console Serial Line ------------------------------------------------------------ Interface standards EIA RS-423-EIA V.10 X.26 EIA RS-232-C/CCITT V.28 DEC-423 Data format 1 start bit, 8 data bits, 0 parity bits, 1 stop bit Baud rates 300; 600; 1200; 2400; 4800; 9600; 19,200; 38,400 ------------------------------------------------------------ Configuration Information ------------------------------------------------------------ Form factor Quad height Power requirements +5 Vdc, 4.8 A; +3.3 Vdc, 0.27 A +12 Vdc (alone), 0.14 A; +12 Vdc (with H3602), 0.55 A; -12 Vdc, 0.04 A Power consumption 42.6 W Bus loads 3.5 ac; 1.0 dc ------------------------------------------------------------ Operating System Support ------------------------------------------------------------ VMS Version 5.4-2 VAXELN Version 3.2 ------------------------------------------------------------ Diagnostic Support ------------------------------------------------------------ MicroVAX Diagnostic Monitor Release 134 and later Self-tests Yes ------------------------------------------------------------ Related Documentation ------------------------------------------------------------ EK-KA660-TM KA660 CPU Technical Manual EK-398AA-MM KA660 CPU System Maintenance ------------------------------------------------------------ Base System Description 1-17 Chapter 2 Option Specifications ------------------------------------------------------------ This chapter lists specifications for the options currently supported in the VAX 4000 Model 200 system, grouped as follows: · Mass storage · Communications · Real-time · Printer · Memory The specifications appear in alphanumerical order within each of the above groups. All weights are approximate. Some of the options are already installed in your system. If you want to add other options, your Digital sales representative can advise you. Option Specifications 2-1 2.1 Options Overview The option specifications include the following, where applicable: · Functional information · Ordering information · Performance · Configuration information · Related documentation Unless otherwise noted, operating system support and diagnostic support for all options are the same as for the KA660 CPU module. 2.1.1 Configuration Options must be properly configured so that the system recognizes them. Each option in a system has a device address, commonly referred to as a control and status register (CSR) address, and an interrupt vector that must be set when the option is installed. Options are usually configured by setting switches or jumpers on modules already configured at the factory or Digital service representatives configure the option when they install it in your system. Self-maintenance customers can find information on setting CSR addresses and interrupt vectors in the Microsystems Options volume of the Entry Systems Service kit. 2-2 VAX 4000 Model 200 Technical Information 2.2.1 KDA50 Controller The KDA50 is an intelligent controller that interfaces with up to four SDI- compatible mass storage devices on the Q22-bus. ------------------------------------------------------------ Functional Information ------------------------------------------------------------ Controller protocol MSCP Bad block replacement Software dependent Supported drives RA60, RA70, RA81, RA82, RA90, RA92 Drives per controller 4 Controllers per system 1 maximum for VMS 5.1 2 maximum for VMS V5.2 and later Drive interconnect Transformer-coupled radial ------------------------------------------------------------ Ordering Information ------------------------------------------------------------ KDA50-SF RA-series disk drive controller, controls up to a maximum of four RA-series devices 1 KDA50-SG Second KDA50 controller, for support of up to four RA-series devices, uses three Q-bus slots 1 ------------------------------------------------------------ Performance ------------------------------------------------------------ Read/Write data transfers Up to 16-byte block mode DMA Data buffering 32 Kbytes Command buffering 20 command and response ring buffers ------------------------------------------------------------ Configuration Information ------------------------------------------------------------ Form factor Two quad height Power requirements +5 Vdc, 13.5 A (typ); +12 Vdc, 0.03 A (typ) Power consumption 67.86 W Bus loads 3.0 ac; 0.5 dc ------------------------------------------------------------ Related Documentation ------------------------------------------------------------ EK-KDA5Q-UG KDA50-Q User 's Guide ------------------------------------------------------------ 1 Field installed option. ------------------------------------------------------------ 2-4 VAX 4000 Model 200 Technical Information 2.2.2 KFQSA Storage Adapter The KFQSA is an intelligent storage adapter that allows Q22-bus systems to communicate with storage peripherals based on the Digital Storage Systems Interconnect (DSSI). ------------------------------------------------------------ Functional Information ------------------------------------------------------------ Controller protocol SSP: to and from Q22-bus host DSSI: to and from ISEs Supported drive RF-series ISEs Drives per adapter 7 Drive interconnect Direct Controllers per system 2 maximum ------------------------------------------------------------ Ordering Information ------------------------------------------------------------ KFQSA-SG RF-series ISE adapter, controls up to a maximum of 7 RF-series ISEs ------------------------------------------------------------ Performance ------------------------------------------------------------ Peak transfer rate 4 Mbytes/second Sustained transfer rate 1.5 Mbytes/second I/O request throughput 190 I/O requests/second (single-sector reads) Error detection DSSI bus parity and check character, all transmissions ------------------------------------------------------------ Configuration Information ------------------------------------------------------------ Form factor Quad height Power requirements +5 Vdc, 5.5 A (typ) Power consumption 27.5 W Bus loads 4.4 ac; 0.5 dc ------------------------------------------------------------ Related Documentation ------------------------------------------------------------ EK-KFQSA-IN KFQ Storage Adapter Installation and User Manual ------------------------------------------------------------ Option Specifications 2-5 2.2.3 KLESI Controller The KLESI-SA is a controller that interfaces with the TU81-Plus tape drive on the Q22-bus. ------------------------------------------------------------ Functional Information ------------------------------------------------------------ Controller protocol TMSCP Supported drive TU81-Plus Drives per adapter 1 Drive interconnect Direct Controllers per system 1 maximum ------------------------------------------------------------ Ordering Information ------------------------------------------------------------ Included with the TU81-Plus tape drive ------------------------------------------------------------ Configuration Information ------------------------------------------------------------ Form factor Dual Power requirements +5 Vdc, 4.0 A (typ); +12 Vdc, 0.0 A (typ) Power consumption 20.0 W Bus loads 0.5 ac; 1.0 dc ------------------------------------------------------------ Related Documentation ------------------------------------------------------------ EK-LESIB-UG KLESI-B Module User 's and Installation Guide ------------------------------------------------------------ 2-6 VAX 4000 Model 200 Technical Information 2.2.4 KZQSA Storage Adapter The KZQSA storage adapter controls the TLZ04 and RRD-series devices on the Q22-bus. ------------------------------------------------------------ Functional Information ------------------------------------------------------------ Adapter protocol TMSCP Supported drive TLZ04; two external cables or two devices Controllers per system 2 ------------------------------------------------------------ Ordering Information ------------------------------------------------------------ KZQSA-SA Factory-installed KZQSA-SF Field-installed ------------------------------------------------------------ Performance Information ------------------------------------------------------------ Peak transfer rate 4 Mbytes synchronous Error detection Q-bus parity ------------------------------------------------------------ Configuration Information ------------------------------------------------------------ Form factor Quad height Power requirements +5 Vdc, 5.5 A (typ); +12 Vdc, 0.0 A (typ) Power consumption 27.5 W Bus loads 4.4 ac; 1.0 dc ------------------------------------------------------------ Related Documentation ------------------------------------------------------------ EK-KZQSA-IN KZQSA Storage Adapter Installation and User Manual ------------------------------------------------------------ Option Specifications 2-7 2.2.5 RA60 Disk Drive The RA60 disk drive is a high-capacity removable disk drive that provides 205 Mbytes of formatted storage space. The VAX 4000 Model 200 supports these drives in separate storage expansion enclosures only. ------------------------------------------------------------ Storage Capacity ------------------------------------------------------------ User capacity 205 Mbytes User capacity (blocks) 400,176 ------------------------------------------------------------ Ordering Information ------------------------------------------------------------ RA60-AF RA60 disk drive and cables BC26V-06 Interconnect cable with connector block ------------------------------------------------------------ Performance ------------------------------------------------------------ Average seek time 41.67 milliseconds Average rotational latency 8.33 milliseconds Average access time 50.30 milliseconds Peak transfer rate 15.84 Mbits/second ------------------------------------------------------------ Physical Specifications ------------------------------------------------------------ Height 26.52 cm (10.44 in) Width 48.26 cm (19 in) Depth 85.09 cm (33.75 in) Weight 68.95 kg (152 lb) ------------------------------------------------------------ Configuration Information ------------------------------------------------------------ Form factor 10.5-in high, full rack width ------------------------------------------------------------ Related Documentation ------------------------------------------------------------ EK-ORA60-UG RA60 Disk Drive User 's Guide ------------------------------------------------------------ 2-8 VAX 4000 Model 200 Technical Information 2.2.6 RA70E Disk Drive The RA70E disk drive is a high-capacity fixed-disk drive that provides 280 Mbytes of formatted storage space. The VAX 4000 Model 200 supports these drives in separate storage expansion enclosures only. ------------------------------------------------------------ Storage Capacity ------------------------------------------------------------ User capacity 280 Mbytes ------------------------------------------------------------ Ordering Information ------------------------------------------------------------ RA70E-SA RA70E disk drive, factory installed RA70E-SF RA70E disk drive, field installed ------------------------------------------------------------ Performance ------------------------------------------------------------ Average seek time 19.5 milliseconds Average rotational latency 7.5 milliseconds Average access time 27.0 milliseconds Peak transfer rate 1.4 Mbytes/second ------------------------------------------------------------ Physical Specifications ------------------------------------------------------------ Height 26.3 cm (10.38 in) Width 44.5 cm (17.5 in) Depth 67.3 cm (26.5 in) Weight 61.2 kg (135 lb) Form factor 5.25-in high, full rack width ------------------------------------------------------------ Related Documentation ------------------------------------------------------------ EK-ORA70-PS RA70 Disk Drive Pocket Reference Card EK-ORA70-SV RA70 Disk Drive Service Manual ------------------------------------------------------------ Option Specifications 2-9 2.2.7 RA81 Disk Drive The RA81 disk drive is a high-capacity fixed-disk drive that provides 456 Mbytes of formatted storage space. The VAX 4000 Model 200 supports these drives in separate storage expansion enclosures only. ------------------------------------------------------------ Storage Capacity ------------------------------------------------------------ User capacity 456 Mbytes User capacity (blocks) 891,070 ------------------------------------------------------------ Ordering Information ------------------------------------------------------------ RA81-HA/-HD RA81 disk drive (120 V/240 V) RQA81-AA RA81 disk drive (120 V) with KDA50 controller and BC26V-06 cable RQA81-AD RA81 disk drive (240 V) with KDA50 controller and BC26V-6D cable BC26V-6D Interconnect cable with connector block ------------------------------------------------------------ Performance ------------------------------------------------------------ Average seek time 28.00 milliseconds Average rotational latency 8.32 milliseconds Average access time 36.30 milliseconds Peak transfer rate 17.4 Mbits/second ------------------------------------------------------------ Physical Specifications ------------------------------------------------------------ Height 26.3 cm (10.38 in) Width 44.5 cm (17.5 in) Depth 67.3 cm (26.5 in) Form factor 10.5-in high, full rack width Weight 61.2 kg (135 lb) ------------------------------------------------------------ Related Documentation ------------------------------------------------------------ EK-ORA81-SV RA81 Disk Drive Service Guide EK-ORA81-UG RA81 Disk Drive User 's Guide ------------------------------------------------------------ 2-10 VAX 4000 Model 200 Technical Information 2.2.8 RA82 Disk Drive The RA82 disk drive is a high-capacity fixed-disk drive that provides 623 Mbytes of formatted storage space. The VAX 4000 Model 200 supports these drives in separate storage expansion enclosures only. ------------------------------------------------------------ Storage Capacity ------------------------------------------------------------ User capacity 623 Mbytes User capacity (blocks) 1,216,660 ------------------------------------------------------------ Ordering Information ------------------------------------------------------------ RA82-AA RA82 disk drive (120 V) with one BC26V-12 cable RA82-AD RA82 disk drive (240 V) with one BC26V-12 cable BC26V-06 Interconnect cable with connector block ------------------------------------------------------------ Performance ------------------------------------------------------------ Average seek time 24.00 milliseconds Average rotational latency 8.33 milliseconds Average access time 32.33 milliseconds Peak transfer rate 19.2 Mbits/second ------------------------------------------------------------ Physical Specifications ------------------------------------------------------------ Height 26.3 cm (10.38 in) Width 44.5 cm (17.5 in) Depth 67.3 cm (26.5 in) Weight 61.2 kg (135 lb) ------------------------------------------------------------ Configuration Information ------------------------------------------------------------ Form factor 10.5-in high, full rack width ------------------------------------------------------------ Related Documentation ------------------------------------------------------------ EK-ORA82-SV RA82 Disk Drive Service Guide EK-ORA82-UG RA82 Disk Drive User 's Guide ------------------------------------------------------------ Option Specifications 2-11 2.2.9 RA90 Disk Drive The RA90 disk drive is a high-capacity fixed-disk drive that provides 1.2 gigabytes of formatted storage space. The VAX 4000 Model 200 supports these drives in separate storage expansion enclosures only. ------------------------------------------------------------ Storage Capacity ------------------------------------------------------------ User capacity 1.2 gigabytes User capacity (blocks) 2,376,153 ------------------------------------------------------------ Ordering Information ------------------------------------------------------------ RA90-NA RA90 disk drive (120 V) RA90-ND RA90 disk drive (240 V) BC26V-12 Interconnect cable with connector block ------------------------------------------------------------ Performance ------------------------------------------------------------ Average seek time 18.5 milliseconds Average access time 8.33 milliseconds Peak transfer rate 22.2 Mbits/second ------------------------------------------------------------ Physical Specifications ------------------------------------------------------------ Height 26.6 cm (10.4 in) Width 23.0 cm (8.7 in) Depth 68.5 cm (27.0 in) Weight 13.6 kg (62 lb) ------------------------------------------------------------ Configuration Information ------------------------------------------------------------ Form factor 10.5-in high, full rack width Power requirements +5 Vdc, 1.3 A; +12 Vdc, 2.21 A Power consumption 18.7 W ------------------------------------------------------------ Related Documentation ------------------------------------------------------------ EK-ORA90-SV RA90 Disk Drive Service Guide EK-ORA90-UG RA90 Disk Drive User 's Guide ------------------------------------------------------------ 2-12 VAX 4000 Model 200 Technical Information 2.2.10 RA92 Disk Drive The RA92 disk drive provides 1.5 Gbytes of formatted storage space. The VAX 4000 Model 200 supports the RA92 only in separate storage expansion enclosures. ------------------------------------------------------------ Storage Capacity ------------------------------------------------------------ User capacity 1.5 gigabytes User capacity (blocks) 2,940,952 ------------------------------------------------------------ Ordering Information ------------------------------------------------------------ RA92-CA/CD RA92 disk drive (120 V @ 60 Hz; 240 V @ 50 Hz) BC26J-xx 12-, 25-, 50, or 80-ft. interconnect cable BC27V-xx 12-, 15-, 25-, 35-, 50-, or 80-ft. interconnect cable ------------------------------------------------------------ Performance ------------------------------------------------------------ Average seek time 16.5 milliseconds Single track seek 3.0 milliseconds Peak transfer rate 22.2 Mbits/second ------------------------------------------------------------ Physical Specifications ------------------------------------------------------------ Height 26.6 cm (10.42 in) Width 23.0 cm (8.75 in) Depth 60.96 cm (24.0 in) Weight 31.8 kg (70 lb) ------------------------------------------------------------ Configuration Information ------------------------------------------------------------ Form factor 10.5-in high Power requirements +5 Vdc, 1.3 A; +12 Vdc, 2.21 A Power consumption 18.7 W ------------------------------------------------------------ Related Documentation ------------------------------------------------------------ EK-ORA92-UG-02 RA90/RA92 User 's Guide ------------------------------------------------------------ Option Specifications 2-13 2.2.11 RF31 Integrated Storage Element (ISE) The RF31 is a DSSI integrated storage element (ISE) that provides 381 Mbytes of formatted storage space. An ISE is a 5.25-inch integrated storage element that is housed in a special mounting bracket for simplified installation and upgrading. ------------------------------------------------------------ Storage Capacity ------------------------------------------------------------ Data storage capacity 381 Mbytes, formatted ------------------------------------------------------------ Ordering Information ------------------------------------------------------------ RF31E-AF 381 Mbyte half-height DSSI ISE, field-installed ------------------------------------------------------------ Performance ------------------------------------------------------------ Average seek time 14.7 milliseconds Average access time 23 milliseconds Peak transfer rate 4.0 Mbytes/second ------------------------------------------------------------ Physical Specifications ------------------------------------------------------------ Height 4.40 cm (1.75 in) Width 14.60 cm (5.75 in) Depth 20.45 cm (8.25 in) Weight 1.81 kg (4.0 lb) ------------------------------------------------------------ Configuration Information ------------------------------------------------------------ Form factor Standard 5.25-in footprint Power requirements +5 Vdc, 1.3 A; +12 Vdc, 2.21 A Power consumption 18.7 W ------------------------------------------------------------ Related Documentation ------------------------------------------------------------ EK-RF72D-IM RF31/RF72 Installation Manual for BA200 Enclosures EK-RF72D-UG RF31/RF72 User Guide ------------------------------------------------------------ 2-14 VAX 4000 Model 200 Technical Information 2.2.12 RF31F Integrated Storage Element The RF31F is a DSSI integrated storage element (ISE) that provides 200 Mbytes of formatted storage space. The RF31F features a code modification to the UVE ROM that makes the RF31F a half-stroke drive. ------------------------------------------------------------ Storage Capacity ------------------------------------------------------------ Data storage capacity 200 Mbytes, formatted ------------------------------------------------------------ Ordering Information ------------------------------------------------------------ RF31F-EA 200-Mbyte half-height ISE, no mounting hardware RF31F-AF 200-Mbyte half-height ISE, field-installed ------------------------------------------------------------ Performance ------------------------------------------------------------ Average seek time 12.3 milliseconds Average access time 20.6 milliseconds Peak transfer rate 4.0 Mbytes/second Transfer rate from the media 2.0 Mbytes/second ------------------------------------------------------------ Physical Specifications ------------------------------------------------------------ Height 4.40 cm (1.75 in) Width 14.60 cm (5.75 in) Depth 20.45 cm (8.25 in) Weight 1.81 kg (4.0 lb) Option Specifications 2-15 ------------------------------------------------------------ Configuration Information ------------------------------------------------------------ Form factor Standard 5.25-in footprint Data surfaces 8 Bits per inch 30,064 Tracks per inch 1,875 Power requirements +5 Vdc, 1.3 A; +12 Vdc, 2.21 A (seeking) Power consumption 18.7 W ------------------------------------------------------------ Related Documentation ------------------------------------------------------------ EK-RF72D-UG-004 RF31/RF72 User Guide EK-RF72D-IM-002 RF31/RF72 Installation Manual ------------------------------------------------------------ 2-16 VAX 4000 Model 200 Technical Information 2.2.13 RF71 Integrated Storage Element (ISE) The RF71 is a DSSI integrated storage element (ISE) that provides 400 Mbytes of formatted storage space. An ISE is a 5.25-inch integrated storage element that is housed in a special mounting bracket for simplified installation and upgrading. ------------------------------------------------------------ Storage Capacity ------------------------------------------------------------ User capacity 400 Mbytes User capacity (blocks) 781,440 ------------------------------------------------------------ Ordering Information ------------------------------------------------------------ RF71E-AA 400 Mbyte DSSI ISE ------------------------------------------------------------ Performance ------------------------------------------------------------ Average random seek time 19.20 milliseconds Average rotational latency 8.33 milliseconds Average access time 34.2 milliseconds Peak transfer rate 1.5 Mbits/second ------------------------------------------------------------ Physical Specifications ------------------------------------------------------------ Height 7.75 cm (3.05 in) Width 14.60 cm (5.75 in) Depth 20.75 cm (8.17 in) Weight 4.09 kg (9.0 lb) ------------------------------------------------------------ Configuration Information ------------------------------------------------------------ Form factor Standard 10.5-in footprint Power requirements +5 Vdc, 1.25 A; +12 Vdc, 1.64 A Power consumption 25.93 W ------------------------------------------------------------ Related Documentation ------------------------------------------------------------ EK-RF71D-IM RF71 Disk Drive Installation Manual EK-RF71D-UG RF71 Disk Drive User 's Guide ------------------------------------------------------------ Option Specifications 2-17 2.2.14 RF72 Integrated Storage Element (ISE) The RF72 is a DSSI integrated storage element (ISE) that provides 1.0 Gbytes of formatted storage space. RF-series ISEs are used in DSSI busses (Digital Storage Systems Interconnect). An ISE is a 5.25-inch integrated storage element that is housed in a special mounting bracket for simplified installation and upgrading. ------------------------------------------------------------ Storage Capacity ------------------------------------------------------------ User capacity 1.0 Gbytes ------------------------------------------------------------ Ordering Information ------------------------------------------------------------ RF72E-AA 1.0 Gbyte ISE ------------------------------------------------------------ Performance ------------------------------------------------------------ Average seek time 13.3 milliseconds Average raw seek time, high speed 10.3 milliseconds Average rotational latency 18.6 milliseconds Peak transfer rate 2.0 Mbytes/second ------------------------------------------------------------ Physical Specifications ------------------------------------------------------------ Height 7.75 cm (3.05 in) Width 14.60 cm (5.75 in) Depth 20.75 cm (8.17 in) Weight 4.09 kg (9.0 lb) ------------------------------------------------------------ Configuration Information ------------------------------------------------------------ Form factor Standard 5.25-in high, full rack width Power requirements +5 Vdc, 1.25 A; +12 Vdc, 3.12 A Power consumption, spin-up 57.1 W Power consumption, seeking 27.7 W 2-18 VAX 4000 Model 200 Technical Information ------------------------------------------------------------ Related Documentation ------------------------------------------------------------ EK-RF72D-IM RF31/RF72 Installation Manual for BA200 Enclosures EK-RF72D-UG RF31/RF72 User Guide ------------------------------------------------------------ Option Specifications 2-19 2.2.15 RRD40 Compact-Disc Subsystem The RRD40 is a CD reader that retrieves data in fixed-length blocks from removable compact-disc media. ------------------------------------------------------------ Functional Information ------------------------------------------------------------ Modes Idle mode Operation mode: search, normal play Orientation Horizontal ------------------------------------------------------------ Ordering Information ------------------------------------------------------------ RRD40-SF Field-installed tabletop CDROM drive ------------------------------------------------------------ Performance ------------------------------------------------------------ Motor stop time 30% of nominal speed within 30 seconds maxi- mum, 5 seconds typical Motor start time 90% of nominal speed within 20 seconds maxi- mum, less than 11 seconds typical Formatted capacity 525 Mbytes with maximum of 600 Mbytes Average transfer rate 153.6 Kbytes/s, mode 1; 176.4 Kbytes/s, mode 2 Average latency 60 µs max inner track; 155 µs outer track Initialization time 15 seconds maximum to sector zero ------------------------------------------------------------ Physical Specifications ------------------------------------------------------------ Height 27.6 cm (11.02 in) Width 8.18 cm (3.27 in) Depth 22.7 cm (9.06 in) Weight 5.0 kg (11.0 lb) ------------------------------------------------------------ Configuration Information ------------------------------------------------------------ Power consumption 19.2 W max; Play mode: 18 W max ------------------------------------------------------------ Related Documentation ------------------------------------------------------------ EK-RRD40-OM RRD40 Disk Drive Owner 's Manual EK-RRD40-SU RRD40 MicroVAX Monitor User 's Guide Updates ------------------------------------------------------------ 2-20 VAX 4000 Model 200 Technical Information 2.2.16 RRD42 Optical Compact-Disc Subsystem The RRD42 is a 600-Mbyte optical CD reader that retrieves data in fixed- length blocks from removable compact-disc media. ------------------------------------------------------------ Functional Information ------------------------------------------------------------ Interface SCSI-2, single-ended, asynchronous To Q-bus systems through KZQSA storage adapter ------------------------------------------------------------ Ordering Information ------------------------------------------------------------ RRD42-AA Embedded disc drive with controller RRD42-DA Tabletop model, with power supply ------------------------------------------------------------ Performance ------------------------------------------------------------ Seek time, average 400 millisecond, (typical) Seek time, max full stroke 800 millisecend, (typical) Rotational speed, innermost track 530 rpm Rotational speed, outermost track 200 rpm Start time 2.0 second (max) Stop time 2.0 second (max) Transfer rate, sustained 150 Kbytes/second Transfer rate, burst 1.50 Mbytes/second (max) ------------------------------------------------------------ Physical Specifications ------------------------------------------------------------ Height 4.15 cm (1.62 in) Width 14.60 cm (5.75 in) Depth 20.80 cm (8.0 in) Weight -AA 1.30 kg (2.8 lb) -DA 2.9 kg (6.30 lb) Option Specifications 2-21 ------------------------------------------------------------ Configuration Information ------------------------------------------------------------ Form factor Standard 5.25-in high, full rack width ------------------------------------------------------------ Related Documentation ------------------------------------------------------------ EK-RRD42-OM RRD42 Disc Drive Owner 's Manual ------------------------------------------------------------ 2-22 VAX 4000 Model 200 Technical Information 2.2.17 TF85 Tape Drive The TF85 is a cartridge tape subsystem that can store up to 2.6 Gbytes. The TF85 is a streaming tape drive with a built-in DSSI (Digital Storage Systems Interconnect) controller, and can be used as a part of a DSSI VAXcluster. ------------------------------------------------------------ Functional Information ------------------------------------------------------------ Recording media Magnetic, metal-particle tape Tape dimensions 1.27 cm (0.5 in) wide, 366 m (1100 ft) long Mode of operation Streaming Recording method Serpentine Recording density 42,500 bits/in Number of tracks 48 Storage capacity 2.6 Gbytes, formatted Transfer rate 800 Kbytes/second, formatted ------------------------------------------------------------ Ordering Information ------------------------------------------------------------ TF85-AA 2.6 GB cartridge tape subsystem for DSSI-based systems; includes tape drive, DSSI controller, tape cartridge, and head cleaning cartridge TF85E-JA Same as -AA but factory-installed TF85-TA Same as -AA but tabletop version, 120 V TF85-TB Same as -AA but tabletop, 220 V ------------------------------------------------------------ Performance ------------------------------------------------------------ Tape start time 300 milliseconds maximum Tape stop time 300 milliseconds maximum Tape speed 390 cm/second (100 in/second) Streaming data rate 800 Kbytes/second Access time (from insertion of tape) TF85 mode 3 min max TK70/50 mode 60 min max Recording technique Two-track parallel, serpentine Burst rate on DSSI bus 3.8 Mbytes/second Option Specifications 2-23 ------------------------------------------------------------ Physical Specifications ------------------------------------------------------------ Height 8.25 cm (3.25 in) Width 14.60 cm (5.70 in) Depth 21.44 cm (8.44 in) Weight 15.4 kg (7.0 lb) ------------------------------------------------------------ Configuration Information ------------------------------------------------------------ Form factor Half-rack, near 5.25-in footprint Power requirements +5 Vdc, 1.8 A (typ); +12 Vdc, 1.0 A (typ) Power consumption 36.3 W Bus loads 0.0 ac; 0.0 dc ------------------------------------------------------------ Related Documentation ------------------------------------------------------------ EK-OTF85-OM TF85 Cartridge Tape Subsystem Owner 's Manual EK-OTK85-RC TL85 Cartridge Tape Drive Reference Card ------------------------------------------------------------ 2-24 VAX 4000 Model 200 Technical Information 2.2.18 TK50 Tape Drive The TK50 is a streaming-tape drive subsystem that can store up to 95 Mbytes on a tape cartridge for backup data storage. ------------------------------------------------------------ Functional Information ------------------------------------------------------------ Recording media Magnetic tape Tape dimensions 1.27 cm (0.5 in) wide, 182.9 m (600 ft) long Mode of operation Streaming Recording method Serpentine Recording density 6667 bits/in Number of tracks 22 Storage capacity 94.5 Mbytes formatted ------------------------------------------------------------ Ordering Information ------------------------------------------------------------ TK50E-AF 95 Mbyte cartridge tape drive TQK50-SF Controller for TK50E-AF ------------------------------------------------------------ Performance ------------------------------------------------------------ Tape start time 300 milliseconds maximum Tape speed 2925 cm (75 in)/second Streaming data rate 62 Kbytes/second Access time (from insertion of tape) 60 minutes maximum Option Specifications 2-25 ------------------------------------------------------------ Physical Specifications ------------------------------------------------------------ Height 8.25 cm (3.25 in) Width 14.60 cm (5.70 in) Depth 21.44 cm (8.44 in) Weight 2.27 kg (5.0 lb) ------------------------------------------------------------ Configuration Information ------------------------------------------------------------ Form factor Standard 5.25-in footprint Power requirements +5 Vdc, 1.5 A; +12 Vdc, 2.4 A Power consumption 36.3 W Bus loads 0.0 ac; 0.0 dc ------------------------------------------------------------ Related Documentation ------------------------------------------------------------ EK-LEP05-OM TK50 Tape Drive Owner 's Manual EK-OTK50-UG TK50 Tape Drive Subsystem Users Guide ------------------------------------------------------------ 2-26 VAX 4000 Model 200 Technical Information 2.2.19 TK70 Tape Drive The TK70 is a streaming-tape-drive subsystem that can store up to 296 Mbytes on a tape cartridge for backup data storage. The TK70 can read data from cartridges recorded on a TK50 drive, but cannot write data to cartridges recorded on a TK50 drive. ------------------------------------------------------------ Functional Information ------------------------------------------------------------ Recording media Magnetic tape Tape dimensions 1.27 cm (0.5 in) wide, 182.9 m (600 ft) long Mode of operation Streaming Recording method Serpentine Recording density 10,000 bits/in Number of tracks 48 Storage capacity 296 Mbytes formatted ------------------------------------------------------------ Ordering Information ------------------------------------------------------------ TK70E-AF 296 Mbyte cartridge tape drive TQK70-SF Controller for TK70E-AF ------------------------------------------------------------ Performance ------------------------------------------------------------ Tape start time 325 milliseconds maximum Tape stop time 200 milliseconds maximum Tape speed 390 cm/second (100 in/second) Streaming data rate 125 Kbytes/second Access time (from insertion of tape) 60 minutes maximum ------------------------------------------------------------ Physical Specifications ------------------------------------------------------------ Height 8.25 cm (3.25 in) Width 14.60 cm (5.70 in) Depth 21.44 cm (8.44 in) Weight 2.27 kg (5.0 lb) Option Specifications 2-27 ------------------------------------------------------------ Configuration Information ------------------------------------------------------------ Form factor Standard 5.25-in footprint Power requirements +5 Vdc, 1.35 A; +12 Vdc, 2.4 A Power consumption 35.6 W Bus loads 0.0 ac; 0.0 dc ------------------------------------------------------------ Related Documentation ------------------------------------------------------------ EK-OTK70-OM TK70 Tape Drive Subsystem Owner 's Manual EK-OTK70-TM TK70 Tape Drive Subsystem Technical Manual EK-OTK70-SM TK70 Tape Drive Subsystem Service Manual ------------------------------------------------------------ 2-28 VAX 4000 Model 200 Technical Information 2.2.20 TLZ04 Tape Drive The TLZ04 is a 1.2 Gbyte cassette (DAT) SCSI tape drive, either tabletop or embedded in the VAX 4000 Model 200 system. ------------------------------------------------------------ Functional Information ------------------------------------------------------------ Recording media Magnetic tape Mode of operation Streaming and start/stop Storage capacity 1.2 Gbytes formatted Drive interface RDAT compatible ------------------------------------------------------------ Ordering Information ------------------------------------------------------------ TLZ04-JA Embedded (factory installed)BA400-series TLZ04-JF Embedded (field installed)BA400-series TLZ04-DA Tabletop TLZ04-GA Tabletop including BC06P cable ------------------------------------------------------------ Performance ------------------------------------------------------------ Passes per cassette tape 300 Media TLZ04-CA cassette tape Bit density 114 Mbits/square inch Transfer rate (sustained) 183 Kbytes/second Recording format Digital data storage (DDS) Read/write speed 0.87 cm/second Peak transfer rate, raw 180 Kbytes/second Peak transfer rate,user data 170 Kbytes/second Average file access time 20 seconds Rewinding time 40 seconds Option Specifications 2-29 ------------------------------------------------------------ Physical Specifications ------------------------------------------------------------ Height 10.0 cm (3.8 in), tabletop 8.2 cm (3.35 in), embedded Width 32.5 cm (12.7 in), tabletop 14.60 cm (5.70 in), embedded Depth 28.5 cm (11.2 in), tabletop 21.44 cm (8.44 in), embedded Weight 7.72 kg (17 lb), tabletop 2.20 kg (7.72 lb), embedded ------------------------------------------------------------ Data Organization ------------------------------------------------------------ Recording technology Helical scan Recording method Digital Data Storage (DDS) Recording density 61,000 bits/inch Record size Variable Maximum capacity 1.2 Gbytes, formatted Recording medium 60 m x 4 mm ------------------------------------------------------------ Maintenance ------------------------------------------------------------ Recommended cleaning cartridge Every 25 hours ------------------------------------------------------------ Configuration Information ------------------------------------------------------------ Form factor 5.25-in DAT drive Power Requirements 90 to 132 V, 1.6 A; 198.0 to 264 V, 1.0 A Power consumption (embedded) 15.0 W Power consumption (tabletop) 50.0 W ------------------------------------------------------------ Related Documentation ------------------------------------------------------------ EK-TLZ04-MM TLZ04 Tape Drive Subsystem Service Manual EK-BA400-IN Tape Drive Subsystem Service Manual EK-TLZ04-OM TLZ04 Tape Drive Owner 's Manual ------------------------------------------------------------ 2-30 VAX 4000 Model 200 Technical Information 2.2.21 TQK70 Controller The TQK70 controller module provides the interface between the TK70 tape drive and the Q22-bus. ------------------------------------------------------------ Functional Information ------------------------------------------------------------ Controller protocol TMSCP Supported drive TK70 Drives per controller 1 Drive interconnect Direct Controllers per system 1 maximum ------------------------------------------------------------ Ordering Information ------------------------------------------------------------ TQK70-SA Controller for TK70E-AF TQK70-SF Controller for TK70E-AF, field-installed ------------------------------------------------------------ Performance ------------------------------------------------------------ Data throughput rate 125 Kbytes/second Read/Write data transfers Up to 16-word burst mode DMA, truncated to 8- word burst mode if another device is requesting the bus Buffer size 64 Kbytes ------------------------------------------------------------ Configuration Information ------------------------------------------------------------ Form factor Dual height Power requirements +5 Vdc, 3.5 A; +12 Vdc, 0.0 A Power consumption 17.5 W Bus loads 4.3 ac; 0.5 dc ------------------------------------------------------------ Related Documentation ------------------------------------------------------------ EK-OTK70-OM TK70 Tape Drive Subsystem Owner 's Manual ------------------------------------------------------------ Option Specifications 2-31 2.2.22 TSZ07 Tape Drive The TSZ07 is a high-capacity, streaming, 9-track, reel-to-reel, half-inch magnetic tape drive with dual recording densities. The TSZ07 is available in tabletop, cabinet, or rackmount models, and cannot be mounted inside the VAX 4000 Model 200 system. ------------------------------------------------------------ Functional Information ------------------------------------------------------------ Recording densities 1600 bits/inch or 6250 bits/inch Mode of operation Streaming and start/stop Storage capacity 40 Mbytes with 8-Kbyte blocks, formatted Number of tracks 9 on 0.5-inch magnetic tape Drive interface RDAT compatible ------------------------------------------------------------ Ordering Information ------------------------------------------------------------ TSZ07-AA Rackmount, specify country kit TSZ07-BA Cabinet, 120 V TSZ07-BB Cabinet, 240 V TSZ07-CA Tabletop, specify country kit ------------------------------------------------------------ Performance ------------------------------------------------------------ Transfer rate 4 Mbytes/s Load/unload time 55 s Recording speed 100 in/s Rewinding speed 150 s (with 2400 reel) 2-32 VAX 4000 Model 200 Technical Information ------------------------------------------------------------ Physical Specifications ------------------------------------------------------------ Tabletop Height 26.78 cm (10.50 in) Width 50.36 cm (19.75 in) Depth 68.85 cm (27.00 in) Weight 36.8 kg (81 lb) Rackmount Height 22.32 cm (8.75 in) Width 43.35 cm (17.0 in) Depth 64.03 cm (25.5 in) Weight 31.8 kg (70 lb) Cabinet Height 101.0 cm (40.0 in) Width 56.10 cm (22.0 in) Depth 76.50 cm (30.0 in) Weight 180.1 kg (238 lb) ------------------------------------------------------------ Maintenance ------------------------------------------------------------ Recommended cleaning cartridge Every 25 hours ------------------------------------------------------------ Configuration Information ------------------------------------------------------------ Form factor 5.25-in DAT drive Power consumption 385 W, cabinet 355 W, tabletop 355 W, rackmount ------------------------------------------------------------ Related Documentation ------------------------------------------------------------ EK-TSZ07-IN-002 TSZ07 Installation/Owner 's Manual EK-TSZ07-TM-002 TSZ07 Technical Manual ------------------------------------------------------------ Option Specifications 2-33 2.2.23 TSV05 Tape Drive The TSV05 is a magnetic streaming-tape-drive that provides 40.5 Mbytes of backup data storage. The TSV05 reads or writes up to 160 Kbytes per second in standard ANSI format. ------------------------------------------------------------ Functional Information ------------------------------------------------------------ Recording media Magnetic tape, 26.7 cm (10.5 in) reel Tape dimensions 1.27 cm (0.5 in) wide, 731 m (2400 ft) long Mode of operation Streaming Recording method Phase encoded (PE) Recording density 1600 bits/in Number of tracks 9 Storage capacity 40 Mbytes formatted ------------------------------------------------------------ Ordering Information ------------------------------------------------------------ TSV05-SB TSV05 tape drive subsystem ------------------------------------------------------------ Performance ------------------------------------------------------------ Handling Bidirectional reel-to-reel with compliance arm Tape velocity 64 or 254 cm/second (25 or 100 in/second) Maximum data transfer rate 40 or 160 Kbytes/second Rewind time (731 m (2400 ft)) 2.8 minutes ------------------------------------------------------------ Physical Specifications ------------------------------------------------------------ Height 23.0 cm (8.75 in) Width 43 cm (17 in) Depth 62 cm (24.5 in) Weight 36 kg (80 lb) Form factor 10.5-in high, full rack width ------------------------------------------------------------ Related Documentation ------------------------------------------------------------ EK-TSV05-UG TSV05 Tape Transport System User 's Guide EK-TSV05-TM TSV05 Tape Transport Subsys Tech Manual ------------------------------------------------------------ 2-34 VAX 4000 Model 200 Technical Information 2.2.24 TSV05 Controller The TSV05 tape drive controller interfaces the TSV05 tape drive to the Q22-bus. ------------------------------------------------------------ Functional Information ------------------------------------------------------------ Controller protocol Controller unique Supported drive TSV05 Drives per controller 1 Drive interconnect Direct ------------------------------------------------------------ Ordering Information ------------------------------------------------------------ TSV05-SB TSV05 tape drive subsystem ------------------------------------------------------------ Performance ------------------------------------------------------------ Buffer size 3.5 Kbytes ------------------------------------------------------------ Configuration Information ------------------------------------------------------------ Form factor Quad height Power requirements +5 Vdc, 6.5 A (typ); +12 Vdc, 0.0 A (typ) Power consumption 32.5 W Bus loads 2.4 ac; 1.0 dc ------------------------------------------------------------ Related Documentation ------------------------------------------------------------ EK-TSV05-UG TSV05 Tape Transport System User 's Guide ------------------------------------------------------------ Option Specifications 2-35 2.2.25 TU81-Plus Tape Drive The TU81-Plus is a reel-to-reel tape drive mounted in a 101.6-cm (40- in) cabinet. The drive supports two industry-standard recording methods: group coded recording (GCR) and phase encoded (PE). ------------------------------------------------------------ Storage Capacity ------------------------------------------------------------ PE unformatted 45.3 Mbytes PE formatted 40.0 Mbytes GCR unformatted 177 Mbytes GCR formatted 140 Mbytes ------------------------------------------------------------ Functional Specifications ------------------------------------------------------------ Recording media Magnetic tape Tape dimensions 1.27 cm (0.5 in) wide, 731 m (2400 ft) long Mode of operation Streaming Recording methods Group code recording (GCR) Phase encoded (PE) Recording density 6250 bits/in (GCR) 1600 bits/in (PE) Number of tracks 9 ------------------------------------------------------------ Ordering Information ------------------------------------------------------------ TU81E-DA TU81-Plus tape drive, KLESI controller for 120 V TU81E-DB TU81-Plus tape drive, KLESI controller for 240 V ------------------------------------------------------------ Performance ------------------------------------------------------------ Handling Bidirectional reel-to-reel Tape velocity High speed 190.5 cm/second (75 in/second) Low speed 63.5 cm/second (25 in/second) Channel data transfer rate PE high speed 120 Kbytes/second PE low speed 40 Kbytes/second GCR high speed 469 Kbytes/second GCR low speed 156 Kbytes/second Rewind time (731.5 m (2400 ft) tape on 26.7 cm (10.5 in) reel) 2.75 minutes maximum 2-36 VAX 4000 Model 200 Technical Information ------------------------------------------------------------ Physical Specifications ------------------------------------------------------------ Height 105.8 cm (41.7 in) Width 54.6 cm (21.5 in) Depth 76.2 cm (30.0 in) Weight 139 kg (295 lb) ------------------------------------------------------------ Related Documentation ------------------------------------------------------------ EK-TU81E-UG TU81-Plus Tape Subsystem User 's Guide ------------------------------------------------------------ Option Specifications 2-37 2.3 Communications Options The VAX 4000 Model 200 system supports the following communications options: · CXA16 asynchronous multiplexer (16 lines) · CXB16 asynchronous multiplexer (16 lines) · CXY08 asynchronous multiplexer (8 lines) · DESQA Ethernet controller · DFA01 asynchronous controller with integral modem · DPV11 synchronous interface · DSRVB DECserver 200 · DSV11 synchronous controller Asynchronous Serial Controllers Asynchronous serial controllers provide low-speed connections between peripheral devices and the system. Asynchronous communications between the system and the peripheral depends on recognition of a pattern of start and stop bits, not on a time interval. Synchronous Serial Controllers Synchronous serial controllers provide high-speed connections between systems. Communication between synchronous devices depends on time intervals that are synchronized before transmission of data begins. Ethernet Controllers Ethernet controllers connect your system to an Ethernet network. With a network connection and appropriate DECnet software, you can use all network services. 2-38 VAX 4000 Model 200 Technical Information 2.3.1 CXA16 Asynchronous Multiplexer (16 lines) The CXA16 is an intelligent, preprogrammed serial controller that can operate in either DHV11 or DHU11 mode, depending on the setting of an on-board switch. The module contains 16 multiplexed lines. ------------------------------------------------------------ Functional Information ------------------------------------------------------------ Supported line interfaces EIA RS-423-A/CCITT V.10 EIA RS-232-D/CCITT V.28 DEC-423 Split-speed operation All lines Flow control (XON/XOFF) All lines Supported data formats 16 programmable formats (each with 1 start bit) · 5, 6, 7, or 8 data bits, 0 or 1 parity bit, and 1 stop bit · 5 data bits, 0 or 1 parity bit, and 1.5 stop bits · 6, 7, or 8 data bits, 0 or 1 parity bit, and 2 stop bits Parity, if enabled, can be either odd or even. Modem control None ------------------------------------------------------------ ------------------------------------------------------------ Ordering Information ------------------------------------------------------------ CXA16-AF CXA16 field-installed kit. Includes two 7.6- m (25-ft) BC16D-25 cables, two H3104 cable concentrators, and other accessories required to install the option. · BC16D-25 cable--data only, 36-conductor, terminated with 36-pin Amphenol male connectors · H3104 cable concentrator--concentrates eight BC16E cables into one BC16D cable; eight modified modular jacks and one 36-pin Am- phenol female connector Option Specifications 2-39 ------------------------------------------------------------ Ordering Information ------------------------------------------------------------ BC16E-series cable Office cable--data only, six-conductor, terminated with modified modular plugs · BC16E-10: 3 m (10 ft) · BC16E-25: 7.6 m (25 ft) · BC16E-50: 15.2 m (50 ft) H8572 Cable extender with modified modular jacks. H8571-A 25-pin passive adapter 1 H8571-B 9-pin passive adapter 1 H3105 Active adapter. Converts EIA RS-232-D signals to DEC-423 signals. ------------------------------------------------------------ Performance ------------------------------------------------------------ Transmit data transfers Single-character transfers or up to 16-character block mode DMA transfers in DHV11 mode. Single-character or two-character transfers, or up to 16-character block mode DMA transfers in DHU11 mode. Receive data transfers Single-character transfers in both DHV11 and DHU11 modes. Transmit buffer size One character for DHV11 mode transfers 64-character FIFO for DHU11 mode transfers 64-character FIFO for DMA transfers in DHU11 and DHV11 modes Receive buffer size 256-character FIFO in DHV11 and DHU11 modes Supported baud rates 16 programmable baud rates: 50; 75; 110; 134.5; 150; 300; 600; 1200; 1800; 2000; 2400; 4800; 7200; 9600; 19,200; 38,400 2 Throughput at maximum baud rate: 5 data bits, 0 parity, 1 stop bit 140,000 characters/s (all lines) 7 data bits, 1 parity bit, 1 stop bit 110,000 characters/s (all lines) ------------------------------------------------------------ Configuration Information ------------------------------------------------------------ Form factor Quad height with integral, recessed cover panel Power requirements +5 Vdc, 1.6 A (typ); +12 Vdc, 0.20 A (typ) Power consumption 10.4 W ------------------------------------------------------------ 1 Converts a D-connector to a modified modular jack. Required for connecting terminals and printers to office cables terminated with modified modular plugs. 2 38,400 baud rate is not supported by Digital operating systems. 2-40 VAX 4000 Model 200 Technical Information ------------------------------------------------------------ Configuration Information ------------------------------------------------------------ Bus loads 3.0 ac; 0.5 dc Module connectors 2 female, 36-pin Amphenol connectors ------------------------------------------------------------ Related Documentation ------------------------------------------------------------ EK-CAB16-UG CXA16/CXB16 User 's Guide EK-CAB16-TM CXA16/CXB16 Technical Manual ------------------------------------------------------------ Option Specifications 2-41 2.3.2 CXB16 Asynchronous Multiplexer (16 lines) The CXB16 is an intelligent, preprogrammed serial controller that can operate in either DHV11 or DHU11 mode, depending on the setting of an on-board switch. The module contains 16 multiplexed lines. ------------------------------------------------------------ Functional Information ------------------------------------------------------------ Supported line interfaces EIA RS-422-A/CCITT V.11 X.27 Split-speed operation All lines Flow control (XON/XOFF) All lines Supported data formats 16 programmable formats (each with 1 start bit) · 5, 6, 7, or 8 data bits, 0 or 1 parity bit, and 1 stop bit · 5 data bits, 0 or 1 parity bit, and 1.5 stop bits · 6, 7, or 8 data bits, 0 or 1 parity bit, and 2 stop bits Parity, if enabled, can be either odd or even. Modem control None ------------------------------------------------------------ Ordering Information ------------------------------------------------------------ CXB16-AF Module and cable kit. Includes two 7.6-m (25-ft) BC16D-25 cables, two H3104 cable concentrators, and other accessories required to install the option. · BC16D-25 cable--data only, 36-conductor, terminated with 36-pin Amphenol male connectors · H3104 cable concentrator--concentrates eight BC16E cables into one BC16D cable; eight modified modular jacks and one 36-pin Am- phenol female connector BC16E-series cable Office cable--data only, six-conductor, terminated with modified modular plugs · BC16E-10: 3 m (10 ft) · BC16E-25: 7.6 m (25 ft) · BC16E-50: 15.2 m (50 ft) 2-42 VAX 4000 Model 200 Technical Information ------------------------------------------------------------ Ordering Information ------------------------------------------------------------ H8572 Cable extender. Null modem cable terminated with modified modular jacks. ------------------------------------------------------------ Performance ------------------------------------------------------------ Transmit data transfers Single-character programmed transfers or up to 16-character block mode DMA transfers in DHV11 mode. Single-character or two-character programmed transfers, or up to 16-character block mode DMA transfers in DHU11 mode. Receive data transfers Single-character programmed transfers in both DHV11 and DHU11 modes. Transmit buffer size One character for programmed transfers in DHV11 mode 64-character FIFO for programmed transfers in DHU11 mode 64-character FIFO for DMA transfers in DHU11 and DHV11 modes Receive buffer size 256-character FIFO in DHV11 and DHU11 modes Supported baud rates 16 programmable baud rates: 50; 75; 110; 134.5; 150; 300; 600; 1200; 1800; 2000; 2400; 4800; 7200; 9600; 19,200; 38,400 1 Throughput at maximum baud rate: 5 data bits, 0 parity bits, 1 stop bit 140,000 characters/second (all lines) 7 data bits, 1 parity bit, 1 stop bit 110,000 characters/second (all lines) ------------------------------------------------------------ Configuration Information ------------------------------------------------------------ Form factor Quad height with integral, recessed cover panel Power requirements +5 Vdc, 2.0 A (typ); +12 Vdc, 0.00 A (typ) Power consumption 10.0 W Bus loads 3.0 ac; 0.5 dc Module connectors 2 female, 36-pin Amphenol connectors ------------------------------------------------------------ 1 38,400 baud rate is not supported by Digital operating systems. Option Specifications 2-43 ------------------------------------------------------------ Related Documentation ------------------------------------------------------------ EK-CAB16-UG CXA16/CXB16 User 's Guide EK-CAB16-TM CXA16/CXB16 Technical Manual ------------------------------------------------------------ 2-44 VAX 4000 Model 200 Technical Information 2.3.3 CXY08 Asynchronous Multiplexer (8 Lines) The CXY08 asynchronous multiplexer performs data concentration, real- time processing, and interactive terminal handling. The CXY08 can operate in either DHV11 or DHU11 mode, depending on the setting of an on-board switch. The CXY08 supports full modem control. ------------------------------------------------------------ Functional Information ------------------------------------------------------------ Supported line interfaces EIA RS-423-A/CCITT V.10 EIA RS-232-D/CCITT V.28 DEC-423 Split-speed operation All lines Flow control (XON/XOFF) All lines Supported data formats 16 programmable formats (each with 1 start bit) · 5, 6, 7, or 8 data bits, 0 or 1 parity bit, and 1 stop bit · 5 data bits, 0 or 1 parity bit, 1.5 stop bits · 6, 7, or 8 data bits, 0 or 1 parity bit, and 2 stop bits Parity, if enabled, can be either odd or even. Modem control Full Supported modems Bell models 103, 113, 212 ------------------------------------------------------------ Ordering Information ------------------------------------------------------------ CXY08-AF CXY08 field-installed kit. Includes two 3.7- m (12-ft) BC19N-12 cable assemblies and other accessories required to install the option. · BC19N-12 cable assembly--concentrates four 11-conductor cables with 25-pin male D-connectors into one 44-connector cable ter- minated by a 50-pin male CHAMP connector. ------------------------------------------------------------ Performance ------------------------------------------------------------ Transmit data transfers Single-character programmed transfers or up to 16-character block mode DMA transfers in DHV11 mode. Option Specifications 2-45 ------------------------------------------------------------ Performance ------------------------------------------------------------ Single-character or two-character programmed transfers, or up to 16-character block mode DMA transfers in DHU11 mode. Receive data transfers Single-character programmed transfers in both DHV11 and DHU11 modes. Transmit buffer size One character for programmed transfers in DHV11 mode 64-character FIFO for programmed transfers in DHU11 mode 64-character FIFO for DMA transfers in DHU11 and DHV11 modes Receive buffer size 256-character FIFO in DHV11 and DHU11 modes Supported baud rates 16 programmable baud rates: 50; 75; 110; 134.5; 150; 300; 600; 1200; 1800; 2000; 2400; 4800; 7200; 9600; 19,200; 38,400 1 Throughput at maximum baud rate: 5 data bits, 0 parity bits, 1 stop bit 87,771 characters/second (all lines) 7 data bits, 1 parity bit, 1 stop bit 61,440 characters/second (all lines) ------------------------------------------------------------ Configuration Information ------------------------------------------------------------ Form factor Quad height with integral, recessed cover panel Power requirements +5 Vdc, 1.64 A (typ); +12 Vdc, 0.395 A (typ) Power consumption 12.94 W Bus loads 3.0 ac; 0.5 dc Module connectors 2 female, 50-pin CHAMP connectors ------------------------------------------------------------ Related Documentation ------------------------------------------------------------ EK-CXY08-UG CXY08 User 's Guide EK-CXY08-TM CXY08 Technical Manual ------------------------------------------------------------ 1 38,400 baud rate is not supported by Digital operating systems. ------------------------------------------------------------ 2-46 VAX 4000 Model 200 Technical Information 2.3.4 DESQA Ethernet Controller The DESQA Ethernet controller provides a high-speed asynchronous connection between a Q22-bus system and a Local Area Network (LAN) based on Ethernet or IEEE 802.3. The DESQA supports either standard or ThinWire Ethernet cabling. ------------------------------------------------------------ Functional Information ------------------------------------------------------------ Supported protocols Ethernet, IEEE 802.3 Maintenance Operation Protocol (MOP) ------------------------------------------------------------ Ordering Information ------------------------------------------------------------ DESQA-SF DESQA field-installed kit External cable (standard) BNE3B or BNE3D External cable (ThinWire) BC16M ------------------------------------------------------------ Performance ------------------------------------------------------------ Transmit/Receive data transfers Up to 32-byte block mode DMA Transmit data transfers 2-Kbyte FIFO for DMA transfers Receive data transfers 4-Kbyte FIFO for DMA transfers Throughput at maximum rate 10 Mbits/second ------------------------------------------------------------ Configuration Information ------------------------------------------------------------ Form factor Quad height Power requirements +5 Vdc, 2.4 A; +12 Vdc, 0.22 A Power consumption 14.64 W Bus loads 2.2 ac; 0.5 dc Module connectors (standard) One 15-pin D-type Module connectors (Thinwire) T-connector to BNC connector on DESQA ------------------------------------------------------------ Related Documentation ------------------------------------------------------------ EK-DESQA-TM DESQA Technical Manual ------------------------------------------------------------ Option Specifications 2-47 2.3.5 DEQRA Token Ring Q-bus Adapter The DEQRA Token Ring Q-bus adapter and its software, TRDRV/VMS, enable Q-bus VAX systems to connect to 4- or 16-Mbits/second Token Ring networks, and to act as full function DECnet Phase IV nodes and pathworks for VMS servers. ------------------------------------------------------------ Functional Information ------------------------------------------------------------ Supported protocols IBM-compatible Token Ring (IEEE 802.5) Operating system supported VMS 5.4 DECTRN Driver VMS 1.0 ------------------------------------------------------------ Ordering Information ------------------------------------------------------------ DEQRA-CA DEQRA module, documentation, and licensed letter BC29E-15 External console ribbon cable, 15-ft OL-GVJAP-AA Software license ------------------------------------------------------------ Performance ------------------------------------------------------------ Data transfer rate 4-Mbits and 16-Mbits ------------------------------------------------------------ Diagnostic Support ------------------------------------------------------------ Diagnostic support Power-on self test MDM Installation Verification Procedure DEQRA specific from host ------------------------------------------------------------ Configuration Information ------------------------------------------------------------ Form factor Quad height Power requirements +5 Vdc, 4.0 A; +12 Vdc, 0.1 A Power consumption 21.2 W Bus loads 2.2 ac; 0.5 dc 2-48 VAX 4000 Model 200 Technical Information ------------------------------------------------------------ Related Documentation ------------------------------------------------------------ EK-DEQRA-IN DECTRN Controller 100 Hardware Installation EK-DEQRA-TM DECTRN Controller 100 Hardware Description AA-PH7NA-TE DECTRN Device Driver for VMS Installation AA-PH7PA-TE DECTRN Device Driver for VMS Use and Programming ------------------------------------------------------------ Option Specifications 2-49 2.3.6 DFA01 Asynchronous Controller with Integral Modem The DFA01 is an asynchronous serial controller that emulates the DZQ11. It has two lines, each with a DF224-compatible integral modem. ------------------------------------------------------------ Functional Information ------------------------------------------------------------ Supported modulation protocols Bell 103J Bell 212A CCITT V.22 CCITT V.22-BIS Split-speed operation Both lines Flow control (XON/XOFF) No Supported data formats 8 programmable formats (each with 1 start bit) · 5, 6, 7, or 8 data bits, 0 or 1 parity bit, and 1 stop bit · 5, 6, 7, or 8 data bits, 0 or 1 parity bit, and 2 stop bits Modem control Full ------------------------------------------------------------ Ordering Information ------------------------------------------------------------ DFA01-AF Field-installed kit ------------------------------------------------------------ Performance ------------------------------------------------------------ Transmit data transfers Single-character programmed transfers Receive data transfers Single-character programmed transfers Transmit buffer size One character for programmed transfers Receive buffer size 64-character FIFO Supported baud rates 8 programmable baud rates: 50, 75, 110, 134.5, 150, 300, 1200, 2400 1 Throughput at maximum baud rate 1200 bytes/second ------------------------------------------------------------ 1 The serial line is capable of baud rates up to 9600 baud. However, because the modem is restricted to speeds of 0-300, 1200, and 2400 baud, all other baud rates are considered illegal and pass meaningless data. 2-50 VAX 4000 Model 200 Technical Information ------------------------------------------------------------ Configuration Information ------------------------------------------------------------ Form factor Quad height with integral, flush cover panel Power requirements +5 Vdc, 1.97 A; +12 Vdc, 0.04 A Power consumption 10.30 W Bus loads 3.0 ac; 1.0 dc Module connectors 4 TELCO: 2 modified modular jacks (MMJ) for data lines; 2 modular jacks (MJ) for voice lines ------------------------------------------------------------ Related Documentation ------------------------------------------------------------ EK-DFA01-UG DFA01 Modem User 's Guide EK-DFA01-IN DFA01 Modem Installation Guide ------------------------------------------------------------ Option Specifications 2-51 2.3.7 DPV11 Synchronous Controller The DPV11 is a single-line programmable controller that provides local or remote interconnections between systems. ------------------------------------------------------------ Functional Information ------------------------------------------------------------ Supported line interfaces EIA RS-232-C/CCITT V.28 EIA RS-423-A EIA RS-422-A Supported protocols DDCMP, BISYNC, and SDLC Operating mode Full or half-duplex Character size Program selectable (5-8 bits with character-oriented protocols and 108 bits with bit-oriented protocols) Modem support Limited Supported modems All Digital modems and the Bell 200 series ------------------------------------------------------------ Ordering Information ------------------------------------------------------------ DPV11-SF Field-installed kit ------------------------------------------------------------ Performance ------------------------------------------------------------ Transmit/Receive data transfers Single-byte programmed transfer Transmit buffer size 2 bytes Receive buffer size 2 bytes Data rate 56 Kbits/second ------------------------------------------------------------ Configuration Information ------------------------------------------------------------ Form factor Dual height Power requirements +5 Vdc, 1.2 A (typ); +12 Vdc, 0.3 A (typ) Power consumption 9.6 W Bus loads 1.0 ac; 1.0 dc ------------------------------------------------------------ Related Documentation ------------------------------------------------------------ EK-DPV11-UG DPV11 Synchronous Interface User 's Guide EK-DPV11-TM DPV11 Technical Manual ------------------------------------------------------------ 2-52 VAX 4000 Model 200 Technical Information 2.3.8 DSRVB DECserver 200 The DSRVB DECserver 200 is an 8-line terminal server used to connect terminals to a host computer on an Ethernet Local Area Network (LAN). Software for the server is downline-loaded from a host to the server. The server is available in two models: the modem control (MC) model has modem control and an RS-232-C line interface; the data leads (DL) model has no modem control and a DEC-423 (DECconnect) line interface. ------------------------------------------------------------ Functional Information ------------------------------------------------------------ Supported line interfaces RS-232-C (MC Model)/DEC-423 (DL Model) Modem control Yes (MC Model)/No (DL Model) Protocols Asynchronous Supported terminal devices VT-, LN-, LA-, and LQ-series devices ------------------------------------------------------------ Ordering Information (hardware only) 1 ------------------------------------------------------------ DSRVB-AA 8-line DECserver 200/MC, RS-232-C line inter- face, 120 V. Includes country kit. 2 DSRVB-BA 8-line DECserver 200/DL, DEC-423 (DECconnect) line interface, 120 V. Includes country kit. DSRVB-AB 8-line DECserver 200/MC, RS-232-C line inter- face, 240 V. Requires country kit. DSRVB-BB 8-line DECserver 200/DL, DEC-423 (DECconnect) line interface, 240 V. Requires country kit. ------------------------------------------------------------ Performance ------------------------------------------------------------ Maximum throughput 8 lines at 19.2 Kbytes/second ------------------------------------------------------------ Physical Specifications ------------------------------------------------------------ Height 11.75 cm (4.63 in) Width 48.90 cm (19.25 in) Depth 32.07 cm (12.63 in) Weight 5.44 kg (12 lb) ------------------------------------------------------------ 1 See the Networks and Communications Buyer 's Guide for appropriate software. 2 Each country kit includes a power cord, hardware manual, and rack mounting brackets. See the Networks and Communications Buyer 's Guide for available country kits. Option Specifications 2-53 ------------------------------------------------------------ Related Documentation ------------------------------------------------------------ AA-HL77B-TK DSRVB DECserver 200 User 's Guide ------------------------------------------------------------ 2-54 VAX 4000 Model 200 Technical Information 2.3.9 DSV11 Synchronous Controller The DSV11 is a two-channel, high-speed, synchronous controller that interfaces Q22-bus backplanes. ------------------------------------------------------------ Functional Information ------------------------------------------------------------ Supported line interfaces RS-423 RF-422 RS-232/V.24, V.35 Supported protocols DDCMP HDLC/SDLC BISYNC Operating mode Full or half-duplex Modem support Full modem control ------------------------------------------------------------ Ordering Information ------------------------------------------------------------ DSV11-SF Field-installed kit (first DSV11) DSV11-SG Field-installed kit (additional DSV11s) ------------------------------------------------------------ Performance Information ------------------------------------------------------------ Transmit/Receive data transfers DMA Data rate, Mbits/second (maximum) RS-232-C/V.24 = up to 20K RS-423 = 100K RS-422 = 256K V.35 = 48K ------------------------------------------------------------ Configuration Information ------------------------------------------------------------ Form factor Quad height Power requirements +5 Vdc, 5.43 A (typ); 12 Vdc, 0.69 A (typ) Power consumption 35.43 W Bus loads 3.9 ac; 1.0 dc ------------------------------------------------------------ Related Documentation ------------------------------------------------------------ EK-DSV11-UG DSV11-S Communications Option User Guide EK-DSV11-TD DSV11 Communications Option Technical Description ------------------------------------------------------------ Option Specifications 2-55 2.4 Real-Time Options Real-time controllers interface devices that monitor processes in environments such as the laboratory or manufacturing. Typically, real- time controllers are parallel devices that transmit more than one bit of information simultaneously. The VAX 4000 Model 200 system supports the following real-time options: · AAV11-S digital-to-analog converter · ADQ32 analog-to-digital converter · ADV11-S analog-to-digital converter · AXV11 controller · DIV32 controller · DRQ3B parallel interface · DRV1W parallel interface · IBQ01 controller · IEQ11 controller · KWV11-S programmable real-time clock 2-56 VAX 4000 Model 200 Technical Information 2.4.1 AAV11-S Digital-to-Analog Converter The AAV11-S is a digital-to-analog converter with DMA capability. The AAV11-S is functionally equivalent to the AAV11-D. ------------------------------------------------------------ Functional Information ------------------------------------------------------------ Circuits Two D/A converter circuits D/A input 12-bit digital input Data notation Binary input notation for unipolar output; offset binary or two's complement input notation for bipolar output. D/A output Voltage Output voltage range is jumper selectable: ±10 V, ±5 V, or 0 V to +10 V. Control signals 4-bit digital output for control signals, such as CRT intensity, blank, unblank, and erase Polarity Unipolar or bipolar output ------------------------------------------------------------ Ordering Information ------------------------------------------------------------ AAV11-SF AAV11-S field-installed kit UDIP-BA 1 Universal data interface panel (UDIP) mounting box UDIP-DB Universal data interface panel (UDIP) UDIP-TA Tabletop enclosure ------------------------------------------------------------ Performance ------------------------------------------------------------ Analog output Voltage ±10 V, at 10 mA ±5 V, at 10 mA 0 V to 10 V, at 10 mA Current 10 mA, at 10 V minimum DC impedance 0.05 typical Linearity (0-10 V) ±1/2 LSB; ±1.2 mV at full-scale range Differential linearity ±1/2 LSB Offset error Adjustable to 0 Offset drift ±15 ppm/at maximum °C Gain accuracy Adjustable to zero Gain drift ±25 ppm/at maximum °C Settling time 6 µs to 0.1% for a p-p output change of 20 V ------------------------------------------------------------ 1 You must order both the UDIP mounting box and the UDIP interface when installing a new option. Option Specifications 2-57 ------------------------------------------------------------ Configuration Information ------------------------------------------------------------ Form factor Dual height Power requirements +5 Vdc, 2.10 A (typ); +12 Vdc, 0.0 A Power consumption 10.5 W Bus loads 2.5 ac; 0.5 dc ------------------------------------------------------------ Related Documentation ------------------------------------------------------------ EK-AV11D-UG Q-Bus DMA Analog System User 's Guide ------------------------------------------------------------ 2-58 VAX 4000 Model 200 Technical Information 2.4.2 ADQ32 Analog-to-Digital Converter The ADQ32 is an analog-to-digital converter with DMA capability. ------------------------------------------------------------ Functional Information ------------------------------------------------------------ Input channels 32 single-ended analog input channels or 16 differential analog input channels; single-ended or differential is programmable Programmable gain 1, 2, 4, or 8; selectable per channel A/D output Resolution 12-bit output data resolution Data notation Straight binary (unipolar), two's complement (bipolar) A/D conversions Can be started by a program, a real-time clock, or an external trigger A/D results Can be received by a programmed I/O transfer or by servicing an interrupt request Interrupts Can be enabled and automatically set Common mode rejection ratio 55 dB at maximum range ------------------------------------------------------------ Ordering Information ------------------------------------------------------------ ADQ32-SF ADQ32 field-installed kit UDIP-BA 1 Universal data interface panel (UDIP) mounting box UDIP-AA Universal data interface panel (UDIP) UDIP-TA Tabletop enclosure ------------------------------------------------------------ Performance ------------------------------------------------------------ Analog input No. of analog inputs 16 channels using differential inputs or 32 channels using single-ended inputs Input range 0 V to +10 V (unipolar); -10 V to +10 V (bipolar) Input impedance 10 M , minimum Input bias current 500 nA maximum ON current Input protection Inputs are current-limited and protected to an overvoltage of ±35 V without damage. Common mode rejection ratio 55 dB ------------------------------------------------------------ 1 You must order both the UDIP mounting box and the UDIP interface when installing a new option. Option Specifications 2-59 ------------------------------------------------------------ Performance ------------------------------------------------------------ A/D output Data buffer register 16-bit read-only output register Resolution 12 bits unipolar; 11 bits bipolar plus sign bit Data notation Straight binary or two's complement Sample and hold amplifier Aperture uncertainty 1 nanosecond Aperture delay 50 nanoseconds, maximum with minimum aperture enabled (clock bypass bit set) Input noise 2 µV p-p A/D converter performance Linearity Differential 0.2 to 2 LSB Integral 1.5 LSB, maximum Scale drift 15 ppm/C typical ------------------------------------------------------------ Performance ------------------------------------------------------------ System throughput Maximum single channel sample rate 250 KHz Maximum multichannel rate to ensure ±1/2 LSB accuracy 200 KHz ------------------------------------------------------------ Configuration Information ------------------------------------------------------------ Form factor Quad height Power requirements +5 Vdc, 4.45 A (typ); +12 Vdc, 0.0 A Power consumption 22.25 W Bus loads 2.5 ac; 0.5 dc ------------------------------------------------------------ Related Documentation ------------------------------------------------------------ EK-153AA-UG ADQ32 Analog-to-Digital Converter User 's Guide ------------------------------------------------------------ 2-60 VAX 4000 Model 200 Technical Information 2.4.3 ADV11-S Analog-to-Digital Converter The ADV11-S is an analog-to-digital converter with DMA capability. The ADV11-S is functionally equivalent to an ADV11-D. ------------------------------------------------------------ Functional Information ------------------------------------------------------------ Input channels 16 single-ended analog input channels or 8 differential analog input channels; SE/DI input is jumper-selectable. Programmable gain 1, 2, 4, or 8 A/D output Resolution 12-bit output data resolution Data notation Binary, offset binary, or two's complement A/D conversions Can be started by a program, a real-time clock, or an external trigger A/D results Can be received by a programmed I/O transfer or by servicing an interrupt request Interrupts Can be enabled and automatically set by A/D DONE and/or ERROR bits Common mode rejection ratio (gain=1) 80 dB at maximum range ------------------------------------------------------------ Ordering Information ------------------------------------------------------------ ADV11-SF ADV11 field-installed kit UDIP-BA 1 Universal data interface panel (UDIP) mounting box UDIP-AB Universal data interface panel (UDIP) for ADV11- S UDIP-TA Tabletop enclosure ------------------------------------------------------------ Performance ------------------------------------------------------------ Analog input No. of analog inputs 8 channels using differential inputs or 16 channels using single-ended inputs Input range 0 V to +10 V (unipolar) -10 V to +10 V (bipolar) Maximum input signal ±10.5 V (signal + common mode voltage) Input impedance Off channels 100 M minimum, 10 pF maximum On channels 100 M minimum, 100 pF maximum ------------------------------------------------------------ 1 You must order both the UDIP mounting box and the UDIP interface when installing a new option. Option Specifications 2-61 ------------------------------------------------------------ Performance ------------------------------------------------------------ Power off 1 K in series with a diode Input bias current ±20 nA at 25°C (77°F) maximum Input protection Inputs are current-limited and protected to an overvoltage of ±35 V without damage. Common mode rejection ratio 80 dB at a range of ±10 V at 60 Hz A/D output Data buffer register 16-bit read-only output register Resolution 12 bits unipolar; 11 bits bipolar plus sign bit Data notation Binary, offset binary, or two's complement Sample and hold amplifier Aperture uncertainty Less than 10 nanoseconds Aperture delay Less than 0.5 µs from start of conversion to signal disconnect Front end settling Less than 15 µs to ±0.01% of full-scale value for a peak-to-peak input of 20 V Input noise Less than 0.2 mV rms A/D converter performance Linearity Less than ±1/2 LSB Stability (temperature coefficient) ±30 ppm at maximum °C (32°F) Stability (long term) ±0.05% change in 6 months System accuracy (gain=1) Input voltage to digitized value to within ±0.03% System throughput 25K channel samples/second ------------------------------------------------------------ Configuration Information ------------------------------------------------------------ Form factor Dual height Power requirements +5 Vdc, 2.0 A (typ); +12 Vdc, 0.0 A Power consumption 10.0 W Bus loads 2.3 ac; 0.5 dc ------------------------------------------------------------ Related Documentation ------------------------------------------------------------ EK-AV11O-UG Q-Bus DMA Analog System User 's Guide ------------------------------------------------------------ 2-62 VAX 4000 Model 200 Technical Information 2.4.4 AXV11 Controller The AXV11-S is an input/output circuit board for analog devices. The AXV11-S is functionally equivalent to the AXV11-C. ------------------------------------------------------------ Functional Information ------------------------------------------------------------ Input channels 16 single-ended analog input channels or 8 differential analog input channels; SE/DI jumper is field-selectable. Programmable gain 1, 2, 4, or 8 A/D output Data resolution 12-bit output data resolution Data notation Binary, offset binary, or two's complement Voltage Output voltage range selection of ±10 V (bipolar) or 0 V to 10 V (unipolar) A/D conversions Can be started by a program, an external trigger, or a real-time clock A/D results Can be received by a programmed I/O transfer or by servicing an interrupt request Common mode rejection ratio 80 dB at maximum range D/A converters (DACs) No. of DACs 2 Input (each DAC) 12-bit digital input Output (each DAC) Unipolar or bipolar output ------------------------------------------------------------ Ordering Information ------------------------------------------------------------ AXV11-SF AXV11 field-installed kit UDIP-BA 1 Universal data interface panel (UDIP) mounting box UDIP-AY Universal data interface panel (UDIP) for AXV11- S UDIP-TA Tabletop enclosure ------------------------------------------------------------ Performance ------------------------------------------------------------ A/D converter performance Linearity To within ±1/2 LSB Stability (temperature coefficient) ±30 ppm at maximum °C (32°F) Stability (long term) ±0.05% change in 6 months Conversion time 25 µs from end of front end settling to setting the A/D DONE bit ------------------------------------------------------------ 1 You must order both a UDIP mounting box and an interface when installing a new option. Option Specifications 2-63 ------------------------------------------------------------ Performance ------------------------------------------------------------ System throughput 25K channel samples/second D/A converter specifications No. of D/A converters 2 Digital input 12 bits (Binary code is used for unipolar output; offset binary or two's complement code is used for bipolar output.) Analog output ±10 V (bipolar) or 0 V to +10 V (unipolar) Output current ±5 mA maximum Output impedance 0.1 Differential linearity To within ±1/2 LSB Nonlinearity 0.02% of full-scale value Offset error Adjustable to 0 Offset drift ±30 ppm at maximum °C (32°F) Gain accuracy Adjustable to full-scale value Gain drift ±30 ppm at maximum °C (32°F) Settling time 65 µs to 0.1% for a peak-to-peak output change of 20 V Noise 0.1% full-scale value Capacitive load capability 0.5 µF ------------------------------------------------------------ Configuration Information ------------------------------------------------------------ Power requirements +5 Vdc, 2.0 A; +12 Vdc, 0.0 A Power consumption 10.0 W Bus loads 1.2 ac; 0.3 dc ------------------------------------------------------------ Related Documentation ------------------------------------------------------------ EK-AXVAA-UG AXV11/KWV11 Module User 's Guide MP-O11291-00 AXV11-C Field Maintenance Print Set ------------------------------------------------------------ 2-64 VAX 4000 Model 200 Technical Information 2.4.5 DIV32 Controller The DIV32 is a quad-height, integrated services digital network (ISDN) communications controller with connection to the Q22-bus backplane. ------------------------------------------------------------ Functional Information ------------------------------------------------------------ Supported line interfaces RS-423 RS-422 RS-232/V.24, V.35 Supported protocols VAX ISDN Operating mode Full- or half-duplex ------------------------------------------------------------ Ordering Information ------------------------------------------------------------ DIV32-SA Factory-installed DIV32-SF Field-installed kit ------------------------------------------------------------ Performance ------------------------------------------------------------ Transmit/Receive data transfers DMA Data transfer rate 64 Kbits/second ------------------------------------------------------------ Configuration Information ------------------------------------------------------------ Form factor Quad height Power requirements +5 Vdc, 5.5 A (typ) Power consumption 27.5 W Bus loads 3.9 ac; 1.0 dc ------------------------------------------------------------ Related Documentation ------------------------------------------------------------ EK-DIV32-UG Communications Option User Guide EK-DIV32-IN DIV Hardware Installation Guide ------------------------------------------------------------ Option Specifications 2-65 2.4.6 DRQ3B Parallel Interface The DRQ3B is a high-speed parallel interface that provides two independent 16-bit, unidirectional data channels. ------------------------------------------------------------ Functional Information ------------------------------------------------------------ Two unidirectional channels Each 512-word FIFO Interrupt vectors One for both DMA channels One for all other interrupts ------------------------------------------------------------ Ordering Information ------------------------------------------------------------ DRQ3B-SF Field-installed kit Cables Connects the DRQ3B to a user device or to another DRQ3B. Order two cables for each DRQ3B module. BC19T-25/-50: 7.6 m (25 ft)/15.2 m (50 ft) ------------------------------------------------------------ Performance ------------------------------------------------------------ Throughput rates Burst: 500 kilowords Block: 1.1 megawords Extended block mode: 1.1 megawords Height speed: 1.4 megawords ------------------------------------------------------------ Configuration Information ------------------------------------------------------------ Form factor Quad height Power requirements + 5 Vdc, 4.5 A; +12 Vdc, 0.0 A Power consumption 22.5 W Bus loads 2.0 ac; 0.5 dc Module connectors Two 50-pin female IEEE connectors I/O port data transceivers Source 16 mA, sink 64 mA ------------------------------------------------------------ Related Documentation ------------------------------------------------------------ EK-O47AA-UG DRQ3B Parallel DMA Input/Output Module User 's Guide ------------------------------------------------------------ 2-66 VAX 4000 Model 200 Technical Information 2.4.7 DRV1W Parallel Interface The DRV1W is a general-purpose, parallel interface with one 16-bit input port and one 16-bit output port. The DRV1W supports DMA. The DRV1W- S is functionally equivalent to the DRV11-WA. ------------------------------------------------------------ Functional Information ------------------------------------------------------------ Number of lines Total: 50 16 data output lines 16 data input lines 3 user-definable input status lines 3 user-definable output control lines 8 input control lines 4 output control lines Line characteristics Input data lines 1 TTL unit load each Input control lines 1 TTL unit load each Output data lines 10 TTL unit loads each Output control lines 10 TTL unit loads each Logic levels High = logic 1 Low = logic 0 ------------------------------------------------------------ Ordering Information ------------------------------------------------------------ DRV1W-SF Field-installed kit ------------------------------------------------------------ Performance ------------------------------------------------------------ Transfer mode Up to 2-byte programmed transfers Up to 8-byte burst mode DMA transfers and unlimited burst mode DMA transfers (unsupported) Data transfer rate Up to 250,000 16-bit words/second in single-cycle mode Up to 500,000 16-bit words/second in burst mode ------------------------------------------------------------ Configuration Information ------------------------------------------------------------ Form factor Dual height Power requirements +5 Vdc, 1.8 A (typ); +12 Vdc, 0.0 A Power consumption 9.0 W Bus loads 2.0 ac; 1.0 dc Option Specifications 2-67 ------------------------------------------------------------ Configuration Information ------------------------------------------------------------ Module connectors Two 40-pin connectors ------------------------------------------------------------ Related Documentation ------------------------------------------------------------ EK-DRVWA-UG DRV11-WA General Purpose DMA User 's Guide ------------------------------------------------------------ 2-68 VAX 4000 Model 200 Technical Information 2.4.8 IBQ01 Controller The IBQ01 is a DMA controller that interfaces a Q22-bus system to RS-485 industrial control and measurement devices. ------------------------------------------------------------ Functional Information ------------------------------------------------------------ Communication protocol Modified SDLC Supported functions Single multidrop interconnect 250 BITBUS compatible devices ------------------------------------------------------------ Ordering Information ------------------------------------------------------------ IBQ01-SF Field-installed kit Cables User-supplied RS-485 BITBUS standard ------------------------------------------------------------ Performance ------------------------------------------------------------ Transfer mode Programmed I/O transfers with interrupt DMA data transfer Data transfer rate Up to 2.4 Mbits/second at BITBUS length of 30 m 375 Kbits/second at BITBUS length of 300 m 62.5 Kbits/second at BITBUS length of 13,200 m ------------------------------------------------------------ Configuration Information ------------------------------------------------------------ Form factor Quad height Power requirements +5 Vdc, 5.0 A; +12 Vdc, 0.3 A Power consumption 28.6 W Bus loads 4.6 ac; 1.0 dc ------------------------------------------------------------ Related Documentation ------------------------------------------------------------ EK-IBQ01-UG DECscan BITBUS Controller User 's Guide EK-IBQ01-IN DECscan BITBUS Controller Installation Manual EK-IBQ01-TM DECscan BITBUS Controller Technical Manual EK-JQ52A-TN DECscan BITBUS Controller Software Installation ------------------------------------------------------------ Option Specifications 2-69 2.4.9 IEQ11 Controller The IEQ11 option is a DMA controller that interfaces a Q22-bus system to two independent instrument buses (IEC/IEEE). ------------------------------------------------------------ Functional Information ------------------------------------------------------------ Supported interfaces IEEE-488-1978 IEC 625-1 Supported interface functions Automatic source handshake Automatic acceptor handshake Talker and extended talker (includes serial poll) Listener and extended listener Service request Remote local Parallel poll Device clear/Device trigger Controller ------------------------------------------------------------ Ordering Information ------------------------------------------------------------ IEQ11-SF Field-installed kit for IEC connection ------------------------------------------------------------ Performance ------------------------------------------------------------ Transfer mode Programmed I/O transfers with interrupt DMA data transfers Data transfer rate 150 Kbytes/s during a DMA block transfer ------------------------------------------------------------ Configuration Information ------------------------------------------------------------ Form factor Quad height Power requirements +5 Vdc, 3.5 A (typ); +12 Vdc, 0.0 A Power consumption 17.5 W Bus loads 2.0 A ac; 1.0 A dc Module connectors Standard 24-pin IEEE 488 connector (IEQAA-AC) Standard 25-pin IEC 625 connector (IEQ11-AD) ------------------------------------------------------------ Related Documentation ------------------------------------------------------------ EK-IEUQ1-UG IEU11-A/IEQ11-A User 's Guide ------------------------------------------------------------ 2-70 VAX 4000 Model 200 Technical Information 2.4.10 KWV11-S Programmable Real-Time Clock The KWV11-S is a programmable real-time clock that can be programmed to count from one to five crystal-controlled frequencies, from an external frequency or event, or from a 50-Hz or 60-Hz line frequency on the Q22- bus. The board can generate interrupts or can synchronize the processor to external events. The KWV11-S clock is functionally equivalent to the KWV11-C. ------------------------------------------------------------ Functional Information ------------------------------------------------------------ Resolution 16 bits Frequencies 5 internal crystal frequencies -- 1 MHz, 100 kHz, 10 kHz, 1 kHz, and 100 Hz Schmitt Triggers 2, each with slope and level controls that can be used to start the clock or generate program interrupts Input Line freq input from BEVNT bus (50 or 60 Hz) Modes 4 programmable modes ------------------------------------------------------------ Ordering Information ------------------------------------------------------------ KWV11-SF Field-installed kit UDIP-BA 1 Universal data interface panel mounting box UDIP-KB Universal data interface panel for KWV11-S UDIP-TA Tabletop enclosure ------------------------------------------------------------ Performance ------------------------------------------------------------ Clock Crystal oscillator 10-MHz base frequency Output ranges 1 MHz, 100 kHz, 10 kHz, 1 kHz, and 100 Hz Oscillator accuracy 0.01% Other sources Line frequency or input at Schmitt Trigger Schmitt-Trigger input signals No. of inputs 2 Input range ±30 V (maximum limits) Triggering range -12 V to +12 V (adjustable) Triggering slope Positive or negative, switch-selectable Source User device Response time Depends on input waveform and amplitude; for TTL logic levels, typically 600 nanoseconds ------------------------------------------------------------ 1 You must order both a UDIP mounting box and an interface when installing a new option. Option Specifications 2-71 ------------------------------------------------------------ Performance ------------------------------------------------------------ Hysteresis Approximately 0.5 V, positive and negative Characteristics Single-ended input, 100-K impedance to gnd Clock output Signal CLK OV L (clock overflow, asserted low) Output pins J1 pin 5 and CLK OVFL tab Function Time base selection from an internal crystal-controlled frequency, an input at ST1, or a line frequency at BEVNT bus line Duration Approximately 500 nanoseconds Line driver TTL-compatible, open collector circuit with a 470- pull-up resistor to +5 V Maximum source current 5 mA when output is high ( 2.4 V), measuring from source through load to ground Maximum sink current 8 mA when output is low ( 0.8 V), measuring from external source voltage through load to output Schmitt-Trigger 1 output Signal ST1 OUT L (asserted low) Output pins J1 pin 2 and ST1 OUT tab Function External time base input or counter. Input frequency is a function of the input signal. Other characteristics Same as clock output Schmitt-Trigger 2 output Signal ST2 OUT L (asserted low) Output pin J1 pin 4 Function Starts counter, sets ST2 flag, and generates an interrupt (if enabled); causes buffer preset register (BPR) to be loaded from counter. Other characteristics Same as clock output ------------------------------------------------------------ Configuration Information ------------------------------------------------------------ Power requirements +5 Vdc, 2.2 A (typ); +12 Vdc, 0.013 A (typ) Power consumption 11.156 W Bus loads 1.0 ac; 0.3 dc ------------------------------------------------------------ Related Documentation ------------------------------------------------------------ EK-AXVAA-UG AXV11/KWV11 Module User 's Guide ------------------------------------------------------------ 2-72 VAX 4000 Model 200 Technical Information 2.5 Printer Interface 2.5.1 LPV11-SA Printer Interface The LPV11 printer interface controls the flow of data between the Q22-bus and a line printer. ------------------------------------------------------------ Ordering Information ------------------------------------------------------------ LPV11-SA LPV11 controller module ------------------------------------------------------------ Configuration Information ------------------------------------------------------------ Form factor Quad height Power requirements +5 Vdc, 2.8 A (typ); +12 Vdc, 0.0 A Power consumption 14.0 W Bus loads 1.8 ac; 0.5 dc Module connectors 2 female, 37-pin D subminiature connectors ------------------------------------------------------------ Related Documentation ------------------------------------------------------------ EK-LPV11-OP LPV11 Printer User 's Manual ------------------------------------------------------------ Option Specifications 2-73 2.6 Graphics Adapters 2.6.1 VS30U Graphics Adapter The VS30U is a full-page, high-resolution DMA color video subsystem capable of 8-plane color video memory display. The VS30U allows field upgrade of Q-bus VAXservers to Q-bus workstations. The option includes the 8-plane color graphics module set (VCB02-J) as well as the 19-in color monitor (VR299) and a keyboard, mouse, and cable. ------------------------------------------------------------ Ordering Information ------------------------------------------------------------ VS30U 3 modules: base module and two 4-plane modules VS30U-G3 GPX upgrade for BA213, VR299, 240 V VS30U-G4 GPX upgrade for BA213, VR299, 240 V SH VS30U-GA GPX upgrade for BA213, VR299, 120 V ------------------------------------------------------------ Configuration Information ------------------------------------------------------------ Form factor Quad height Power requirements Base module at +5 Vdc, 5.8 A (typ) Base module at +12 Vdc, 0.7 A (typ) 4-plane module at +5 Vdc, 3.4 A (typ) ------------------------------------------------------------ 2-74 VAX 4000 Model 200 Technical Information Chapter 3 System Expansion ------------------------------------------------------------ This chapter provides guidelines on how to expand your VAX 4000 Model 200 system. 3.1 Planning System Expansion You must consider the following when you decide to expand your system: · Can your system accommodate additional supported options? You determine this by filling in the appropriate worksheet (Figure 3-1 or Figure 3-2) with the options currently installed in your system and those you wish to add. · If your existing system cannot accommodate a particular set of supported options, you might wish to add one of the following expanders, to enable support for the RA-series or RF-series ISEs. NOTE: When combining BA215 and BA430 enclosures in the same VAXcluster, you must use grounding kit H4010-AA. ------------------------------------------------------------ Expander Name Additional Q-22-Bus Slots Additional Storage Capacity ------------------------------------------------------------ B213F 11 Up to three RF-series ISEs. R215F 0 Up to three RF-series ISEs. B400X 11 Up to four RF-series disk drives or three tape drives and and one TK or TF series tape drive. R400X 0 Up to seven RF-series disk drive or six RF-series ISEs, with room for one TLZ04 tape drive. ------------------------------------------------------------ This chapter does not describe how to configure new options or how to install them in your system. Configuring an option involves assigning a control and status register (CSR) address and an interrupt vector. This is usually done System Expansion 3-1 by means of switches or jumpers on the options themselves. Digital service representatives configure the options when they install them. Your Digital service representative also determines the proper placement of options within your system, according to specific guidelines. 3.2 Completing the VAX 4000 Model 200 Configuration Worksheets To determine what options you can add to your system, you must list the options currently installed and their power requirements on the appropriate VAX 4000 Model 200 Configuration Worksheet, provided in Figure 3-1 and Figure 3-2. The worksheet in Figure 3-1 is for the BA430 enclosure. All backplane slots and mass storage devices are powered by the H7874 power supply. The worksheet in Figure 3-2 is for the BA215 enclosure. Use the worksheets as follows: 1. In the Module column, list all options and mass storage devices currently installed in your system, except the controller for the tape drive. The processor module, one memory module, and the tape drive has already been entered. Use the label on the cover panel of each slot to identify the module installed in that slot. 2. List each RF-series ISE. 3. List the options and mass storage devices you wish to add to your system. 4. List the controller for the tape drive last. 5. Fill in the power requirements for each module and each mass storage device. The power requirements for the more common options are listed in Table 3-1; refer to the option descriptions in Chapter 2 for the power requirements of additional options. 6. Add each column and make sure the totals do not exceed the specified limit. As long as the figures are within range, you can probably install the new option(s). NOTE: The worksheets are only guides. Confirm your plan with your Digital sales representative. While certain configurations may be possible, they may not be recommended due to excessive loads on the system or difficulties in arranging bus and cable access to all devices. 3-2 VAX 4000 Model 200 Technical Information Figure 3-1: VAX 4000 Model 200 (BA430 Enclosure) Configuration Worksheet System Expansion 3-3 Figure 3-2: VAX 4000 Model 200 (BA215 Enclosure) Configuration Worksheet 3-4 VAX 4000 Model 200 Technical Information Table 3-1: Power Requirements ------------------------------------------------------------ Current (Amps) Max ------------------------------------------------------------ Power Max ------------------------------------------------------------ Bus Loads ------------------------------------------------------------ Option Module +5 V +12 V Watts AC DC ------------------------------------------------------------ AAV11-SA A1009-PA 2.10 0.00 10.50 2.5 0.5 ADQ32-SA A030 4.45 0.00 22.25 2.5 0.5 ADV11-SA A1008-PA 2.00 0.00 10.00 2.3 0.5 AXV11-SA A026-PA 2.00 0.00 10.00 1.2 0.3 CXA16-AA M3118-YA 1.60 0.20 10.40 3.0 0.5 CXB16-AA M3118-YB 2.00 0.00 10.00 3.3 0.5 CXY08-AA M3119-YA 1.64 0.395 12.94 3.0 0.5 DESQA-SA M3127-PA 2.40 0.22 14.64 3.3 0.5 DFA01-AA M3121-PA 1.97 0.04 10.30 3.0 1.0 DIV32-SA M7571-PA 5.5 0.00 35.4 3.5 1.0 [B DPV11-SA M8020-PA 1.20 0.30 9.60 1.0 1.0 DRQ3B-SA M7658-PA 4.50 0.00 22.50 2.0 0.5 DRV1J-SA M8049-PA 1.80 0.00 9.00 2.0 1.0 DRV1W-SA M7651-PA 1.80 0.00 9.00 2.0 1.0 DSV11-SA M3108 5.43 0.69 35.43 3.9 1.0 H3602 - 0.30 0.50 6.50 - - H3604 1 - 1.70 0.50 14.50 - - IBQ01-SA M3125-PA 5.00 0.30 28.60 4.6 1.0 IEQ11-SA M8634-PA 3.50 0.00 17.50 2.0 1.0 KA660-AA/BA 4 M7626-AA/BA 4.8 0.55 30.60 4.0 1.0 KDA50-SE M7164 6.93 0.00 34.65 3.0 0.5 --- M7165 6.57 0.03 33.21 - - KFQSA-SA/SE M7769 5.50 0.00 27.50 4.4 0.5 KLESI-SA/SF M7740-PA 4.00 0.00 20.00 0.5 1.0 KRQ50-SA M7552 2.70 0.00 13.50 2.7 1.0 KWV11-SA M4002-PA 2.20 0.013 11.156 1.0 0.3 KXJ11-SF M7616 6.0 0.7 46.8 2.0 1.0 KZQSA-SA/SF M5976 5.4 0.0 27.0 4.4 0.5 LPV11-SA M8086-PA 2.80 0.00 14.00 1.8 0.5 M9404-PA M9404 - 0.00 0.0 - - M9405-PA M9405 - 0.00 0.0 - - MRV11-D M8578 1.60 3 0.00 8.00 3.0 0.5 MS650-BA M7622-AA 3.5 0.00 17.5 - - ------------------------------------------------------------ 1 Also include -12 Vdc @ 0.25 A, 3 W. 3 Value is for the unpopulated module only. 4 Includes the power requirement of the H3602. System Expansion 3-5 Table 3-1 (Cont.): Power Requirements ------------------------------------------------------------ Current (Amps) Max ------------------------------------------------------------ Power Max ------------------------------------------------------------ Bus Loads ------------------------------------------------------------ Option Module +5 V +12 V Watts AC DC ------------------------------------------------------------ MS650-BB M7622-BB 3.1 0.00 15.5 - - RF31E-AA/AF - 1.2 2.21 32.52 N/A N/A RF31F-AA/AF - 1.2 2.21 32.52 N/A N/A RF71E-AA/AF - 1.25 1.64 25.93 N/A N/A RF72E-AA/AF - 1.20 1.75 27.00 N/A N/A RZ56E-AA/AF - 1.36 2.1 32.0 N/A N/A RZ57E-AA/AF - 1.36 2.1 32.0 N/A N/A TF85E-JA/JF - 1.50 2.40 36.30 N/A N/A TK50E-AA - 1.50 2.40 36.30 N/A N/A TK70E-AA - 1.50 2.40 36.30 N/A N/A TLZ04-JA/JF - 1.5 2.4 36.3 N/A N/A TQK50-SA/SF M7546 2.9 0.00 14.5 2.8 0.5 TQK70-SA/SF M7559 3.50 0.00 17.50 4.3 0.5 TSV05-SA M7530 6.50 0.00 32.50 1.5 1.0 VCB02-A M7615 4.6 0.10 24.2 3.5 1.0 VCB02-B M7168-00 M7169 8.85 0.47 49.89 3.5 1.0 VCB02-C (2) M7168-00 M7169 12.0 0.47 65.64 3.5 1.0 ------------------------------------------------------------ 3-6 VAX 4000 Model 200 Technical Information Index ------------------------------------------------------------ A ------------------------------------------------------------ Asynchronous serial controllers description of, 2-38 B ------------------------------------------------------------ BA430 enclosure, 1-1 Base system description of, 1-1 Break Enable/Disable switch description of enable setting, 1-4 C ------------------------------------------------------------ Communications options supported, list of, 2-38 Console commands qualifier and argument conventions in Console I/O mode, 1-6 Console I/O mode and examples of SET and SHOW commands, 1-9 console commands, 1-6 description of, 1-4 Console program, 1-3 and power-up mode, 1-4 entering Console I/O mode, 1-4 Control and status register (CSR) assigning, 3-1 description of, 2-2 Controllers, mass storage supported in KA660 systems, list of, 2-3 CSR See Control and status register D ------------------------------------------------------------ Device abbreviations, 1-13 DHU11 mode and CXA16 support, 2-39 and CXB16 support, 2-42 DHV11 mode and CXA16 support, 2-39 and CXB16 support, 2-42 Digital Storage Systems Intercon- nect See DSSI DSSI description of, 1-14 E ------------------------------------------------------------ Expanding your system, 3-1 F ------------------------------------------------------------ Firmware system control of, 1-3 I ------------------------------------------------------------ Integrated storage element (ISE) and support on DSSI bus, 1-14 RF-series, description of, 2-14, 2-15, 2-17, 2-18 Interrupt vector description of, 2-2 K ------------------------------------------------------------ KA660-AA/-BA module system names for, 1-15 Index-1 M ------------------------------------------------------------ Mass storage controllers See Controllers Modules KA660-AA/-BA CPU, location of, 1-1 MS650-Bx memory, location of, 1-1 MS650-Bx module and maximum supported number, 1-1 N ------------------------------------------------------------ Network controllers description of, 2-38 P ------------------------------------------------------------ Power supply minimum load, 3-6 Power-up self-tests description of, 1-3 R ------------------------------------------------------------ Real-time options supported, list of, 2-56 S ------------------------------------------------------------ Self-tests See Power-up self-tests SET BOOT command, 1-12 SET command description of, 1-9 SET LANGUAGE command, 1-11 SHOW command description of, 1-9 SHOW DEVICE display, 1-11 SHOW ETHERNET display, 1-11 SHOW LANGUAGE display, 1-11 SHOW QBUS display, 1-9 Storage devices supported in KA660 systems, list of, 2-3 Synchronous serial controllers description of, 2-38 V ------------------------------------------------------------ VMB description of, 1-3 Index-2