_ DEC-O-LOG for 55XXX _ DOL, 55XXX-O001, T3001-AA CIO Modules Jun 92 PROBLEM: 1. Module Magnetic Indicators were inadvertently set causing problem installations. 2. Model VAXft 612, during node shutdown would crash rather than do a graceful shutdown. FIELD EFFECTIVITY: Retrofit all T3001-AA CIO modules that are below Rev. P*. This FCO should only be installed on field spares. This FCO incorporates the following ECO: T3001-AA-TW005 - New Part Revision "P01". SOLUTION: This RBD PROM has been updated with changes for VMB, RBD and FIST. This fix is accomplished by replacing a ROM on the T3001-AA module. QUICK CHECK: Look for P/N 23-327E9-00 at location E23. The DEC on-site labor charge will be the time required to install and test the FCO at the then current hourly rate. FCO KIT ORDERING EQ-01648-01 23-327E9-00 ROM 36-19209-16 Brady Marker "P" 36-19208-01 Brady Marker "1" FA-04984-01 FA Document