_ DEC-O-LOG for 885BA _ DOL, 885BA-O001, VAX 8820/8830/8840 Systems, Apr 89 PROBLEM: The MicroVAX Console Subsystem fails to load microcode or diagnostics into the CPU. The MicroVAX interface (QC module) propagates noise on the CC reply line causing improper strobing of the data. FIELD EFFECTIVITY: This FCO should be installed on all MicroVAX 630PS Console Subsystems used on VAX 8820/8830/8840 systems. This will change the revision of the 630PS Console to rev. "C3" by replacing the M7553 QC module with a rev. "C3". This FCO will also change the revision of the 885BA CPU Kernel to "C1". QUICK CHECK: Check for Revision C* of the M7553 module. FCO KIT ORDERING EQ-01481-01 FCO, Parts FA-04840-01 FCO Document _ DOL, 885BA-F002, VAX 8820/8830/8840 Systems, Aug 90 885BA-F002 AUG 90 - PROBLEM: This FCO corrects the problem of the memory box intermittently failing to power-up from either a power failure or power-on command and adds a filter cable to the MOV sense line in the memory box. FIELD EFFECTIVITY: This "F" coded FCO should be installed on all 8820/8830/8840 systems. This will change the revision of the kernals to "D1" and the 630PS to rev. "D3" QUICK CHECK: The console is at revision 8.0 or higher. This can be checked by using the Show Rev Sensed command. Check for presence of MOV Sense Cable (17-02438-01) in location J29 on the power controller in the CPU cabinet. FCO KIT ORDERING EQ-01575-01 FCO, Parts FA-04902-01 FCO Document