_ DEC-O-LOG for BC56A _ DOL, BC56A-M001, BC56A Coax Cable JAN 86 PROBLEM: This FCO eliminates the possibility that BC56A-XX Coax Cable (P/N 17-00185-00) could act as a transporter of flame from a Bulkhead Connector to an area outside the equipment cabinet. FIELD EFFECTIVITY: Replace the BC56A-02 with the BC56A-10 (Rev "A1") between DMR11, DMP11, and DMV11 Bulkhead Connector and the existing BC55M or S Cable. The intent of this FCO is to insure that 10 ft. of P/N 17-00488-01 is installed between the Bulkhead Connector and the existing Cable BC55M or BC55S (P/N 17-00185-00). Phase in BC56A-XX utilizing the Coax Cable (P/N 17-00488-01). ECO BC56A-MK001 will modify the Coax Cable type. Purge SR17, Field SRs, and CD Kits of all BC56A-XX stock that uses Coax Cable P/N 17-00185-00. QUICK CHECK: Approved Cable is BC56A-XX with identification P/N 17-00488-01 imprinted on the Coax Cable jacket. The DEC on-site labor charge will be the time required to install and test the FCO at the current hourly rate. FCO KIT ORDERING: EQ-01390-01 FCO, PARTS FA-04671-01 FCO only