_ K-RM-CI750-A-0 Rev C, CI750 Revision Matrix, Sep 1990 _________________________________________________________________________________________________________________________________ | OPTION NAME: | REVISION HISTORY OF: | |CI750--AA/AB/BA/BB/BC/BD/CA/CB/FA/FB/HA/HB/SA/SB | CI750 - CMI TO CI ADAPTER | |_________________________________________________|______________________________________________________________________________| | | FUNCTIONAL HISTORY OF CHANGES WITH EACH PASS | UNIT VARIATIONS | |____RM_ECO_#__________| | COVERED BY THIS | | | | DOCUMENT | | | CI750 REVISION MATRIX |----------------------| | CI750-TW010 | | CI750-AA/AB | | | Updated documentation to correctly list the minimum compatable part revisions |----------------------| | | for the CI750. | CI750-BA/BB | | | |----------------------| | CI750-MK009 | Updated documentation associated with introduction of the L0118 Link Module. | CI750-BC/BD | | | |----------------------| | CI750-MK008 | Initial release of this document | CI750-CA/CB | | | |----------------------| | | | CI750-FA/FB | | | |----------------------| | | | CI750-HA/HB | | | |----------------------| | | | CI750-SA/SB | | | |----------------------| | | | | | | |----------------------| | | | | | | |----------------------| | | | | | | |----------------------| | | | | | | |----------------------| | | | | | | |----------------------| | | | | | | |----------------------| | | | | | | |----------------------| | | | | | | |----------------------| | | | | | | |----------------------| | | | | | | |----------------------| | | | | | | |----------------------| | | | | |______________________|__________________________________________________________________________________|______________________| | | | | | | | | | | | | THIS DRAWING AND THE SPECIFICATIONS CONTAINED |DRN: L. REED |DATE: 29APR88 | d | i | g | i | t | a | l | | HEREIN ARE CONFIDENTIAL AND PROPRIETARY. THEY |___________________________|_________________|_____|___|___|___|___|___|______| | ARE THE PROPERTY OF DIGITAL EQUIPMENT | | | TITLE | | CORPORATION AND SHALL NOT BE REPRODUCED OR |CHK'D: F. CARBONE |DATE: 29APR88 | CI750 REVISION | | COPIED OR USED IN WHOLE OR IN PART AS THE |___________________________|_________________| MANAGEMENT DOCUMENT | | BASIS FOR THE MANUFACTURE OR SALE OF ITEMS | | |________________________________| | WITHOUT WRITTEN PERMISSION. THIS IS AN |RESP.ENG.: M. JOHNSON |DATE: 29APR88 |SHEET 1 OF 10 | | UNPUBLISHED WORK PROTECTED UNDER THE FEDERAL |___________________________|_________________|________________________________| | COPYRIGHT LAWS. _____________________________ | | | FILENAME: CI750AB.RMF | | Revision Matrix |MFG.ENG.: M. JOHNSON |DATE: 29APR88 | DOCUMENT NUMBER | | (History) |___________________________|_________________|________________________________| | |FIELD | |SIZE|CODE| NUMBER | REV | | |SERVICE: B. GAYTON |DATE: 29APR88 | K | RM | CI750-A-0 | C | ---------------------------------------------------------------------------------------------------------------------------------- ____________________________________________________________________________________________________________________________________ | OPTION NAME: | REVISION HISTORY OF: | |CI750--AA/AB/BA/BB/BC/BD/CA/CB/FA/FB/HA/HB/SA/SB | CI750 - CMI TO CI ADAPTER | |----------------------------------------------------------------------------------------------------------------------------------| | CI750 REVISION MATRIX | | ----------------------- | | | | TABLE OF CONTENTS | | ------------------- | | | | Section Page | | | | 1.0 Introduction.................................................. 3 | | 1.1 How to read Rev Matrices...................................... 4 | | | | 2.0 CI750--AA/AB/BA/BB/BC/BD/CA/CB/FA/FB/HA/HB/SA/SB | | 2.1 History Revision.............................................. 5 | | 2.3 Matrices...................................................... 9 | | | | 3.0 INDEX......................................................... 10 | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | |__________________________________________________________________________________________________________________________________| | | | | | | | |TITLE | | DOCUMENT NUMBER | | | | | | | | | | |________________________________| | d | i | g | i | t | a | l | CI750 REVISION MANAGEMENT DOCUMENT | Sheet 2 of 10 |SIZE|CODE| NUMBER | REV | | | | | | | | | | | K | RM | CI750-A-0 | C | |___|___|___|___|___|___|___|____________________________________________________|________________|____|____|________________|_____| ____________________________________________________________________________________________________________________________________ | OPTION NAME: | REVISION HISTORY OF: | |CI750--AA/AB/BA/BB/BC/BD/CA/CB/FA/FB/HA/HB/SA/SB | CI750 - CMI TO CI ADAPTER | |----------------------------------------------------------------------------------------------------------------------------------| | 1.0 INTRODUCTION | | -------------- | | | | The purpose of this document is to define the compatible revision levels of the CI750. Revision levels are tracked | | according to DEC Standard 068. | | | | A team composed of Engineering, Manufacturing and Customer Service will review all changes and determine when the | | revisions in this document will be changed. This document is under ECO control and will be updated by Engineering | | via the normal ECO process. | | | | This RM document can be obtained in the following manner: | | | | (1) Order from Engineering Design Services by P/N K-RM-CI750-A-0 | | (2) VAX Library Microfiche | | (3) ENET - Copy VOLKS::CLUSTER$REV:CI750_REV.DOC | | (Latest version always available) | | | | This document will be updated when an ECO is generated to a part of sub assembly that causes the revision of the | | option and any supported configuration to change. | | | | All revision noted in this document are MINIMUM REVISIONS. Higher revisions are compatible unless otherwise noted. | | | | Part revisions are tracked according to DEC Standard 012 conventions. Each part has an alphanumeric revision, up to a | | maximum of 4 digits. When a part revision changes, the alpha character, numeric or both may change: if the alpha | | character changes the new part is compatible with and can replace earlier revisions - a "C1" can replace an "A1" and | | a "B1"; if the numeric only changes, the new part is interchangeable and backwards compatible - D1, D2 and D3 are | | interchangeable and can replace earlier revisions. | | | | All unit variations listed are covered by this REV matrix document. In the interest of space, the matrix itself is | | confined to major assemblies. The unit revisions all track with, and are changed with the CI750 option revision. | | | | CI750 UNIT VARIATIONS | | | | VAR | TITLE | | -----------------|----------------------------------------------------------- | | CI750-AA | CI750 CI PORT TO STAR COUPLER, 120V | | CI750-AB | CI750 CI PORT TO STAR COUPLER, 240V | | CI750-BA | CI750-AA WITH FCC HARDENED H9542, 120V | | CI750-BB | CI750-AB WITH FCC HARDENED H9542, 240V | | CI750-BC | CI750-AA W/FCC H9542, W/O SC004-A, 120V | | CI750-BD | CI750-AB W/FCC H9542, W/O SC004-A, 240V | | CI750-CA | CI750-AA W/O L0009, 120V | | CI750-CB | CI750-AB W/O L0009, 240V | | CI750-FA | DUAL CI750-AA, SC004-A, 2 X 877D, W/FCC H9542, 120V | | CI750-FB | DUAL CI750-AB, SC004-A, 2 X 877D, W/FCC H9542, 240V | | CI750-HA | CI750-FA, W/O SC004-A, 120V | | CI750-HB | CI750-FB, W/O SC004-A, 240V | | CI750-SA | 2 X CI750-BA, 1 X SC008-AC, 2 X BNCIA-10, 120V | | CI750-SB | 2 X CI750-BB, 1 X SC008-AC, 2 X BNCIA-10, 240V | |_______________________________|__________________________________________________________________________________________________| | | | | | | | |TITLE | | DOCUMENT NUMBER | | | | | | | | | | |________________________________| | d | i | g | i | t | a | l | CI750 REVISION MANAGEMENT DOCUMENT | Sheet 3 of 10 |SIZE|CODE| NUMBER | REV | | | | | | | | | | | K | RM | CI750-A-0 | C | |___|___|___|___|___|___|___|____________________________________________________|________________|____|____|________________|_____| ____________________________________________________________________________________________________________________________________ | OPTION NAME: | REVISION HISTORY OF: | |CI750--AA/AB/BA/BB/BC/BD/CA/CB/FA/FB/HA/HB/SA/SB | CI750 - CMI TO CI ADAPTER | |----------------------------------------------------------------------------------------------------------------------------------| | | | 1.1 HOW TO READ MATRICES | | | | | | These revision history sections are broken down into two major sections: | | | | (1) Description of changes (History Page). | | | | This describes what parts/units were changed and why. It will contain the following at a minimum: | | ECO#, problem corrected, symptom, new part revision, quick check, FCO# and any other comments that | | the team decides is necessary. | | | | (2) Matrices showing revision compatibilities. | | | | These matrices list the MINIMUM compatible revisions for each part. Higher revisions are also | | compatible unless otherwise noted. | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | |__________________________________________________________________________________________________________________________________| | | | | | | | |TITLE | | DOCUMENT NUMBER | | | | | | | | | | |________________________________| | d | i | g | i | t | a | l | CI750 REVISION MANAGEMENT DOCUMENT | Sheet 4 of 10 |SIZE|CODE| NUMBER | REV | | | | | | | | | | | K | RM | CI750-A-0 | C | |___|___|___|___|___|___|___|____________________________________________________|________________|____|____|________________|_____| ____________________________________________________________________________________________________________________________________ | OPTION NAME: | REVISION HISTORY OF: | |CI750--AA/AB/BA/BB/BC/BD/CA/CB/FA/FB/HA/HB/SA/SB | CI750 - CMI TO CI ADAPTER | |----------------------------------------------------------------------------------------------------------------------------------| | 2.1 HISTORY REVISION | | | | CI750 REVISION J3 | | __________________ | | | | *CREATION DATE IS SEPT 1990. | | *THIS REVISION CHANGED THE CI750 FROM "H" TO "J" | | *THIS REVISION UPDATES THE MINIMUM COMPATABLE REVISIONS OF THE CI750. | | *QUICK CHECK - VERIFY THE PRESENCE OF THE CI750 OPTION REVISION J. | | *DIAGNOSTIC RELEASE 28 (EVNDX 28). Contains the minimum usable diagnostics for the L0118 Module | | | | CI750 REVISION F3 | | ------------------ | | *CREATION DATE I JUNE 1987 | | *This revision changed the CI750 from "E2" to "F3". | | *THIS REVISION CHANGE INVOLVED AN ECO TO THE L0009 MODULE WHICH REWORKS REV A1 AND A2 MODULES TO REV B2 AND REV A3 | | MODULES TO REV C3. THE NEW 'MINIMUM USABLE REVISION' FOR THIS MODULE IS B2. | | *PROBLEM/CORRECTION | | L0009-MK003 1. CMI control state machine selects incorrect command/address and function/vector register data onto | | the bus during certain state transitions. This problem was observed to occur after the detection | | of a CRD Memory error by the port CMI Interface and may result in data corruption. | | | | Correction: 1. Reprogram CMI FPLA to select proper register onto CMI at the appropriate state transitions. | | 2. Replace FPLA E26 (Part No. 23-095C6-00) with new E26 (Part No. 23-121C6-00). | | | | *THIS REVISION CHANGE INVOLVED AN ECO TO THE L0100 MODULE BRINGING THE MODULE REV TO "E" | | *PROBLEM/CORRECTION | | L0100-MK006 1. Original 140 Mhz clock and associated hardware has tendency to drift off frequency. | | 2. Existing wires caused by ECO #MK005 cause extensive manufacturing costs. | | The following corrections are implemented by this ECO: | | 1. Change 140 Mhz crystal to new hybrid oscillator (PN 18-23940-01) and delete unnecessary hardware. | | 2. Phase in new etch to remove wire's on module. | | | | | |__________________________________________________________________________________________________________________________________| | | | | | | | |TITLE | | DOCUMENT NUMBER | | | | | | | | | | |________________________________| | d | i | g | i | t | a | l | CI750 REVISION MANAGEMENT DOCUMENT | Sheet 5 of 10 |SIZE|CODE| NUMBER | REV | | | | | | | | | | | K | RM | CI750-A-0 | C | |___|___|___|___|___|___|___|____________________________________________________|________________|____|____|________________|_____| ____________________________________________________________________________________________________________________________________ | OPTION NAME: | REVISION HISTORY OF: | |CI750--AA/AB/BA/BB/BC/BD/CA/CB/FA/FB/HA/HB/SA/SB | CI750 - CMI TO CI ADAPTER | |----------------------------------------------------------------------------------------------------------------------------------| | | | L0100-MK005 1. Major problems in the interface which would be highly visible in large cluster configurations. | | These problems include the following: | | a) CI 20 self directed packet problem. | | b) Arbitration problem. | | c) Sync detect PAL could latch up under a flood condition. | | d) Implementation of the Xtend Hdr jumper was incorrect. | | e) Acknowledge turn-around and basic slot time causing excessive collisions on the wire. | | f) Correct trailer time to meet the spec. | | 1. The following corrections are implemented by this ECO: | | a) CRC byte counter reset now with (ILIB ABORT + INIT FNC L) * - (ILIB INIT L). | | b) First try flag is now incorporated to provide real arbitration where the node is now | | synchronized on loss of carrier and will obey the rules of dual round robin Arb. | | c) New PAL will be incorporated. | | d) Xtend Hdr jumper now functional. | | e) Install a change to make alter delta time jumper select a basic slot time of 7 to 10 clock ticks.| | *********************************************** NOTE ************************************************ | | | | *Quick Check - (Module REV E) L0100 With wire From a) E65.13 and E177.13 b) E65.11 and E177.9 | | *Diagnostic EVCGD, V1.2 REQUIRED for this ECO. Updated in Diagnostic release 26 (EVNDX 26). | | | | *THIS REVISION CHANGE INVOLVED AN ECO TO THE L0400 MODULE BRINGING THE MODULE REV TO "D" | | *PROBLEM/CORRECTION | | L0400-MK003 1. E181 may cause glitch on power fail causing erroneous second interrupt to CPU. | | 1. Correct problem by adding R62 to E181 pin 10 to prevent glitch. | | | | L0100 Jumper W1 (Module REV E1) or S3 (Module REV E2) indicates the following conditions: | | A) Jumper (W1) installed between E177 socket pins 11 and 12, or Switch (S3) OPEN, DISABLED: | | | | 1) This makes the L0100 downwards compatible with REV. D L0100 modules, by maintaining the basic slot count to | | the existing count of seven (7) ticks, acknowledge turn-around remains the same as the original REV D L0100's,| | and the trailer extension is not enabled. With these eliminated, the ECO'ed L0100 (REV E) will maintain | | form, fit and function as the NON-ECO'ed (REV D) modules. However, it should be noted that the following | | fixes will still be installed and be functional in REV E, while in the DISABLED position: | | New Sync Detect PAL, CI20 fix, XTEND HDR jumper, and XMIT STATUS BIT 3. | | | | B) Jumper (W1) installed between E177 socket pins 9 and 10, or Switch (S3) CLOSED, ENABLED: | | | | 1) Basic slot time now implemented to ten (10) ticks | | | | 2) Ack TURN-AROUND change fully implemented. | | | | 3) Trailer extension by two (2) bytes, fully functional. | | | | 4) Arbitration and FIRST TRY FLAG full implementation. | | | | 5) New Sync detect pal, XTEND HDR JUMPER, CI20 and XMIT STATUS BIT 3, will still be fully functional as above. | | | |__________________________________________________________________________________________________________________________________| | | | | | | | |TITLE | | DOCUMENT NUMBER | | | | | | | | | | |________________________________| | d | i | g | i | t | a | l | CI750 REVISION MANAGEMENT DOCUMENT | Sheet 6 of 10 |SIZE|CODE| NUMBER | REV | | | | | | | | | | | K | RM | CI750-A-0 | C | |___|___|___|___|___|___|___|____________________________________________________|________________|____|____|________________|_____| ____________________________________________________________________________________________________________________________________ | OPTION NAME: | REVISION HISTORY OF: | |CI750--AA/AB/BA/BB/BC/BD/CA/CB/FA/FB/HA/HB/SA/SB | CI750 - CMI TO CI ADAPTER | |----------------------------------------------------------------------------------------------------------------------------------| | 2.3 MATRICES | | | | CI750 REVISION E1 | | ------------------- | | *CREATION DATE IS JULY 1986 - MANUFACTURING DATE. | | *This revision changed the CI750 from "D1" to "E1" | | *THIS REVISION CHANGE INVOLVED AN ECO TO THE L0101 MODULE BRINGING THE MODULE REV TO "J1". | | *PROBLEM/CORRECTION | | L0101-MK009 1. NUMEROUS FUNCTIONAL ERRORS ("ARBITRATION TIMEOUT", INTERNAL QUEUE RETRY ERROR"). | | 2. NEED A VARIABLE SANITY TIMER. | | 3. NEED TO CHECK THE "VALID" BIT WHEN REFERENCING A CACHE BUFFER DESCRIPTION. | | 4. CORRECT DOCUMENTATION ERRORS. | | | | CORRECTION IS V7.0 CI MICROCODE AND 6 PROMS | | | | NOTE THAT THE L0101 REV J1 AND CI780.BIN REV 7.0 MUST BE USED TOGETHER | | | | | | | | | | L0101-MK010 1. PATHS CROSSED, "REQID" SENT ON PATH A, RESPONSE ON PATH B. | | 2. CLOCK THE TRANSMIT ENABLE FLOP CORRECTLY TO PREVENT CLUSTER HUNG. | | | | CI750 Revision "D1" | | --------------------- | | Creation Date - November 1985. | | This revision changed the CI750 from "C" to "D". There was no hardware ECO required. This was a microcode change | | only. The CI780.BIN file changed from V3.0 to V4.0 - console media BE-T204I-DE. This fixed problems found during | | extensive in-house testing of very large VAXclusters under specific conditions, where the CI750 interface will | | sometimes incorrectly recover from CI error conditions. | | | | Comments: An FCO was generated. It was recommended that the new FCO be implemented on all CI750's. | | EQ-01364-01 - CI780.BIN Rev. V5.0 (11/750 console media) | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | |__________________________________________________________________________________________________________________________________| | | | | | | | |TITLE | | DOCUMENT NUMBER | | | | | | | | | | |________________________________| | d | i | g | i | t | a | l | CI750 REVISION MANAGEMENT DOCUMENT | Sheet 7 of 10 |SIZE|CODE| NUMBER | REV | | | | | | | | | | | K | RM | CI750-A-0 | C | |___|___|___|___|___|___|___|____________________________________________________|________________|____|____|________________|_____| ____________________________________________________________________________________________________________________________________ | OPTION NAME: | REVISION HISTORY OF: | |CI750--AA/AB/BA/BB/BC/BD/CA/CB/FA/FB/HA/HB/SA/SB | CI750 - CMI TO CI ADAPTER | |----------------------------------------------------------------------------------------------------------------------------------| | | | CI750 Revision "C" | | ------------------ | | Creation Date - May 1985, mfg ship date. | | *This revision changed the CI750 from "B" to "C". There was no hardware ECO required. This was a microcode change only. | | The CI780.BIN file changed from V3.0 to V4.0 - console media BE-T204H-DE. | | This fixed miscellaneous error type 12 and type 13 introduced by V3.0 of the microcode. | | Comments: An FCO was generated. It is recommended that the new FCO be implemented on all CI750's. | | | | EQ-01343-01 - CI780.BIN Rev. V4.0 (11/750 console media) | | | | NOTE 1: VAX Console designations refer to designated console letter for each revision level to obtain the correct console | | part number. For example, the "C" option revision level required BE-T204H-DE as a minimum for the CI750 | | standard console. | | | | CI750 Revision "B1" | | ------------------- | | Changed revision of the CI750 from "00" (A) to "B". | | *Creation Date - November 1984 MFG ship date | | *This revision change involved ECO to the L0101 module as follows: | | L0101-TW006 - Virtual circuits are closed by unrecognized commands. | | Virtual circuit closure due to micro confusion. | | Port hangs due to conflict in queue access. | | This was a microcode and ROM change. Required CI780.BIN V3.0, console media BE-T204G-DE. | | Comments: An FCO was implemented on all CI750's to upgrade them to Rev. "B". | | EQ-01309-01 ROMS for the L0101 module. | | EQ-01309-02 CI780.BIN Rev. V3.0 11/750 console media. | | | | | | | | | | THIS IS THE INITIAL INTRODUCTION OF THE REVISION MATRIX FOR THE CI750 | | CI750 Revision "00" | | -------------------- | | CI750/CPU Combinations: | | *Creation Date - May 1984 FCS. | | *11/750 CPU must have minimum of 2 megabytes of memory. | | *CI750 Rev. 00 and CPU at Rev. 5; supported only if no UDA is on the system. | | *CI750 Rev. 00 and CPU at Rev. 6; unsupportable. | | *CI750 Rev. 00 and CPU at Rev. 7; supportable for all systems, required if running UDA50. | | *Only 1 (one) CI750 is supportable per CPU. | | *Combination of a CI750 and a DR750 is unsupportable. | | L0101 Rev. F only - CPU console tape should be BE-T204D-DE. VMS Rev. 4.X requires CPU console Tape BE-T204G-DE or later. | | *VMS 3.5 requires CPU to have local disk. | | | | | | | | | | | |__________________________________________________________________________________________________________________________________| | | | | | | | |TITLE | | DOCUMENT NUMBER | | | | | | | | | | |________________________________| | d | i | g | i | t | a | l | CI750 REVISION MANAGEMENT DOCUMENT | Sheet 8 of 10 |SIZE|CODE| NUMBER | REV | | | | | | | | | | | K | RM | CI750-A-0 | C | |___|___|___|___|___|___|___|____________________________________________________|________________|____|____|________________|_____| ____________________________________________________________________________________________________________________________________ | OPTION NAME | R | | | | | | | | | | | |CI750--AA/AB/BA/BB/BC/BD/CA/CB/FA/FB/HA/HB/SA/SB| E | 00 | **B | C | D | E | F | H | J | | | |________________________________________________|_V_|_______|_______|_______|_______|_______|_______|_______|_______|_______|_____| | PART NO. | DESCRIPTION | |___________|______________________________________________________________________________________________________________________| | | | | | | | | | | | | | | L0009 | CCI MODULE | A | A | A | A | A | B | C | C | | | |___________|______________________________________|_______|_______|_______|_______|_______|_______|_______|_______|_______|_______| | | | | | | | | | | | | | | L0100 | CI LINK INTERFACE | D | D | D | D | D | E | N/A | N/A | | | |___________|______________________________________|_______|_______|_______|_______|_______|_______|_______|_______|_______|_______| | | | | | | | | | | | | | | L0101 | CI CONTROL STORE & PACKET BUFFER | F | H | H | H | J, K | K | K | K | | | |___________|______________________________________|_______|_______|_______|_______|_______|_______|_______|_______|_______|_______| | | | | | | | | | | | | | | L0400 | DATA PATH MODULE | B | B | B | B | B | D | D | D | | | |___________|______________________________________|_______|_______|_______|_______|_______|_______|_______|_______|_______|_______| | | | | | | | | | | | | | | PCS750 | 11/750 MICROCODE | 97 | 97 | 97 | 97 | 99 | 99 | 99 | 99 | | | |___________|______________________________________|_______|_______|_______|_______|_______|_______|_______|_______|_______|_______| | | | | | | | | | | | | | |BE-T204*-ME| TU58 #41 VAX 11/750 CONSOLE | D | G | H | I | L | N | N | O | | | |___________|______________________________________|_______|_______|_______|_______|_______|_______|_______|_______|_______|_______| | | | | | | | | | | | | | | EVNDX | VAX DIAGNOSTIC INDEX | 14 | 18 | 19 | 19 | 19 | 26 | 28 | 28 | | | |___________|______________________________________|_______|_______|_______|_______|_______|_______|_______|_______|_______|_______| | | | | | | | | | | | | | | H877-D | 120 POWER CONTROLLER | * | * | * | * | * | * | * | * | | | |___________|______________________________________|_______|_______|_______|_______|_______|_______|_______|_______|_______|_______| | | | | | | | | | | | | | | H877-B | 240 POWER CONTROLLER | * | * | * | * | * | * | * | * | | | |___________|______________________________________|_______|_______|_______|_______|_______|_______|_______|_______|_______|_______| |* | | | | | | | | | | | | | CI780.BIN | CI MICROCODE FILE | | | | | | 7.0 | 7.0 | 8.7 | | | |___________|______________________________________|_______|_______|_______|_______|_______|_______|_______|_______|_______|_______| | | | | | | | | | | | | | | L0118 | CI ENHANCED LINK INTERFACE | - | - | - | - | - | - | B2 | B2 | | | |___________|______________________________________|_______|_______|_______|_______|_______|_______|_______|_______|_______|_______| | | | | | | | | | | | | | | | | | | | | | | | | | | |___________|______________________________________|_______|_______|_______|_______|_______|_______|_______|_______|_______|_______| | NOTES: | R | | | | | | | | | | | | |* | E H | E | E I | E I | E I | E I | E I | E I | C M | C T | | | |.BIN REVISION IS COMPRISED OF RAM.ROM| V I | C | C N | C N | C N | C N | C N | C N | I K | I W | | | | | I S | O | 0 I | O I | O I | O I | O I | O I | 7 0 | 7 0 | | | | | S T | | T | T | T | T | T | T | 5 0 | 5 1 | | | | | I O | N | # | # | # | # | # | # | 0 9 | 0 0 | | | | | O R | O | | | | | | | | | | | | | N Y |___|_______|_______|_______|_______|_______|_______|_______|_______|_______|_______| | | | D | / | / | / | / | / | / | 5/ | 9 / | / | / | | Revision Matrix (Top Level | | A | / | / | / | / | / | / | 30/ | 19 / | / | / | | and Compatibility) | | T | | | | | | | 88 | 90 | | | |_____________________________________|________|_E_|_______|_______|_______|_______|_______|_______|_______|_______|_______|_______| | | | | | | | |TITLE | | DOCUMENT NUMBER | | | | | | | | | | |________________________________| | d | i | g | i | t | a | l | CI750 REVISION MATRIX | Sheet 9 of 10 |SIZE|CODE| NUMBER | REV | | | | | | | | | | | K | RM | CI750-A-0 | C | |___|___|___|___|___|___|___|____________________________________________________|________________|____|____|________________|_____| ____________________________________________________________________________________________________________________________________ | OPTION NAME | REVISION HISTORY OF | | | | |----------------------------------------------------------------------------------------------------------------------------------| | | | | | | | 3.0 INDEX | | ------------ | | | | Item Page | | | | CI750 UNIT VARIATIONS......................................... 3 | | BB-T204*-ME................................................... 9 | | EVNDX......................................................... 9 | | H877-B........................................................ 9 | | H877-D........................................................ 9 | | L0009......................................................... 9 | | L0100......................................................... 9 | | L0101......................................................... 9 | | L0400......................................................... 9 | | PCS750........................................................ 9 | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | |__________________________________________________________________________________________________________________________________| | | | | | | | |TITLE | | DOCUMENT NUMBER | | | | | | | | | | |________________________________| | d | i | g | i | t | a | l | CI750 REVISION MANAGEMENT DOCUMENT | Sheet 10 of 10 |SIZE|CODE| NUMBER | REV | | | | | | | | | | | K | RM | CI750-A-0 | C | |___|___|___|___|___|___|___|____________________________________________________|________________|____|____|________________|_____| \\VAX_REV_MATRIX