_ DEC-O-LOG for CK-DMP11-AD _ DOL, CK-DMP11-AD-B1-R001, Round Cable DEC 85 IN-PLANT EFFECTIVITY: NOV 85 PROBLEM: 1. When running EVDMA (VAX-11 Systems) or CZDMS (PDP-11 Systems), the diagnostic will fail with a Data Miscompare error. 2. In network applications, the DMP11 reports Data errors, Network Dropout and CRC errors. FIELD EFFECTIVITY: Replace the BC08S-10 with the (P/N 70-20956-10) Cable on CK-DMP11-AD RS232C configurations installed in the VAX 11/750 cabinets or the BA11A type CPU/Mounting boxes which exhibit the symptoms listed in the Problem/Symptoms section of this FCO. QUICK CHECK: Presence of (P/N 70-20956-10) Round Cables installed between the M8203 and the H3001 I/O panel. The DEC on-site labor charge will be the time required to install and test the FCO at the then current hourly rate. FCO KIT ORDERING: EQ-01386-01: FCO, PARTS FA-04668-01: FCO only