_ DEC-O-LOG for CK-DUP11-AD _ DOL, CK-DUP11-AD-C1-R001, Round Cable DEC 85 IN-PLANT EFFECTIVITY: NOV 85 PROBLEM: 1. When running EVDUQ (VAX-11 Systems) or DEC/X DPBBO (PDP-11 Systems), the diagnostic will fail with "NOT ENOUGH INTERRUPTS OCCURRED". 2. In network applications, the DUP11 reports Data errors, Network Dropout and CRC errors. FIELD EFFECTIVITY: Replace the BC08S-10 with the (P/N 70-20956-10) Cable on CK-DUP11-AD RS232C configurations installed in the VAX 11/750 cabinets or the BA11A type CPU/Mounting boxes which exhibit the symptoms listed in the Problem/Symptoms section of this FCO. QUICK CHECK: Presence of (P/N 70-20956-10) Round Cables installed between the M7867 and the H3001 I/O panel. The DEC on-site labor charge will be the time required to install and test the FCO at the then current hourly rate. FCO KIT ORDERING: EQ-01385-01: FCO, PARTS FA-04669-01: FCO only