_ DEC-O-LOG for KA45 _ DOL, KA45-F001 FEB 93 PROBLEM: Version V1.1 firmware (contained in 2 EPROM's) has the following bugs: * Halt value incorrect (NVRAM gets erased on Halt) * SCSE devices not seen after self-test failure * TSZ07 self-test failure * LA120 failure when used as a console device FIELD EFFECTIVITY: This FCO applies to MicroVax 3100 Models 30, 40 and 80 with Version V1.1 firmware. SOLUTION: Replace the V1.1 firmware (EPROM's P/N 23-149E8-00 and 23-150E-00) with V1.2 (EPROM's P/N 23-223E8-00 and 23-224E8-00). QUICK CHECK: With system in console mode (">>>" prompt), enter the command >>> SHOW CONFIG. The top line on the console terminal display should say: KA45-A V1.2-343-V4.0 (Model 30/40) and KA47-A V1.2-343-V4.0 (Model 80). Look for V1.2. If it is at V1.1, then this FCO is required. FCO KIT ORDERING EQ-01663-01 23-224E8-00 & 23-223E8-00 EPROMS 36-19208-02 "2" Brady Marker 36-19209-05 "E" Brady Marker 36-19209-08 "H" Brady Marker FA-04999-01 FCO Document _ DOL, KA45-F002 SEP 94 APPLICABILITY: This "F" coded FCO should be installed in all Microvax 3100 Model 30, 40, and 80 which contain part rev. below "M02" or "M03" for FRU 54-20654-01 (Model 30 and Model 40) and part rev. below "J02" or "J03" for FRU 54-20652-01 (Model 80). This FCO incorporates ECO No. 54-20654-TWO007 for Model 30 and Model 40 and ECO No. 5420652-TWO006. Please do not make a separate trip to install FCO unless customer is down. Install the FCO at the next scheduled visit. PROBLEM & SYMPTOM: Previous revision FRU does not see RZ26L and RZ28 drives, if present when booting the system. This problem is caused by SCSI RESET too short. This FCO will also correct: 1. MOP SYSID broadcasting alternates MOP3/MOP4 message, 2. SCSI Verify command now with greater than 64K block count size, 4. New VMB addresses MOP4 response time issues. SOLUTION: Replace two Firmware ROMS located on FRUs 54-20654-01 and 54-20652-01. For FRU 54-20654-01: Replace ROM 23-266E8-00 or ROM 23-223E8-00 or ROM 23-149E8-00 at location E167 with new ROM 23-284E8-00 and replace ROM 23-267E8-00 or ROM 23-224E8-00 or ROM 23-150E8-00 at location E168 with new ROM 23-285E8-00. For FRU 54-20652-01: Replace ROM 23-266E8-00 or ROM 23-223E8-00 or ROM 23-149E8-00 at location E15 with new ROM 23-284E8-00 and replace ROM 23-267E8-00 or ROM 23-224E8-00 or ROM 23-150E8-00 at location E16 with new ROM 23-285E8-00. QUICK CHECK: For FRU 54-20654-01: KA45-A V1.4-38D-V4.2 appears on screen during power up self test. For FRU 54-20652-01: KA47-A V1.4-38D-V4.2 appears on screen during power up self test FCO KIT ORDERING: EQ-01704-01 ROMS 23-284E8-00 and 23-285E8-00 36-19208-03 "3" Brady Marker 36-19208-02 "2" Brady Marker 36-19209-10 "J" Brady Marker 36-19209-13 "M" Brady Marker FA-05041-01 FCO Document