_ DEC-O-LOG for KN15-AA _ DOL, KN15-AA-O002, Interaction between TURBOchannel DMA reads and I/O writes OCT 93 - PROBLEM: The problem manifests itself as an interaction between TURBOchannel DMA reads and conflicted I/O writes, and results in the possibility of a system hanging forever. The system will require a hard reset to clear this system hang. All this is invis ible to the software, since conflicts on the TURBO channel are purely a hardware feature. This revised FCO supersedes KN15-AA-O002, dated 01-Jun-1993. FIELD EFFECTIVITY: This is an as needed FCO and should only be used on DEC 3000 AXP Model 500/500S systems that meet ALL the following crite ria: 1. The system is exhibiting the symptoms described below. 2. The system module (54-21149-01) is below revision level J05 for D etch modules or J06 for F etch mod ules. 3. Any options that utilize the TURBOchannel DMA reads feature, such as: TNVRAM JV2 PMAG-D PMAGB-EA DEFTA KZTSA-AA PMAGB-DA PMAGB-FA NOTE: This option list is not all inclusive. Some 3rd party TURBOchannel options may also contribute to this problem SOLUTION: The solution for this problem is to re place the system module (54-21149-01) with a new sys tem module - Rev. J05 D etch, or Rev. J06 F etch. QUICK CHECK: The system module (54-21149-01) is at minimum revision level J05 for D etch or J06 for F etch modules, and the system complies with the three criteria listed above. FCO KIT ORDERING EQ-01676-01 54-21149-01 System Module and FA Document FA-05012-01 Field Application Document (FA Document) _ DOL, KN15-AA-O003, Emanation of smoke with H7883-AA & H7883-YA power supplies JUN 93 - PROBLEM: Under certain failure modes there are indications for a potential of emanation of smoke accompanied by soot with the H7883-AA and H7883-YA power supplies. FIELD EFFECTIVITY: This is a "O" coded FCO and should be used on all DEC3000 AXP Model 500/500S systems with a H7883-AA below revision J01, and all DEC3000 AXP Model 500X systems with a H7883-YA power supply below revision C01. SOLUTION: The solution for this problem is to re place the power supply harness (Part Number 70- 30004-01 Rev A01) with a new harness (Part Number 70-30004-01 Rev B01). QUICK CHECK: For a H7883-AA power supply the minimum revision is J01, and for a H7883-YA power supply the minimum revision is C01. FCO KIT ORDERING EQ-01677-01 70-30004-01 Fused Cable, FA Document, Revision Level Labels FA-05013-01 Field Application Document (FA Document) _ DOL, KN15-AA-F004, SCSI Controller transaction error KN15-AA-F004 JUN 94 APPLICABILITY: This FCO is customer installable and it should be installed by Customer Services ONLY when demanded by the customer. This FCO is for all DEC3000/* Alpha AXP Workstations shipped beginning December 1992 until November 1, 1993, plus all DEC 3000 Model 600 and 600S systems shipped before February 16, 1994. PROBLEM & SYMPTOM : There is an EXTREMELY REMOTE possibility that in a below normal temperature environment, a SCSI controller transaction error could occur. Through extensive testing below normal operating temperatures, all observed occurrences of this condition have resulted in a detected illegal command. Because this condition in THEORY could cause data corruption we have supplied a MUP which will fix this condition. SOLUTION: Installation of this MUP will provide enhanced parity protection on SCSI controller transactions by programming parity pass through instead of parity generation in the SCSI controller chip(s). QUICK CHECK: None FCO KIT ORDERING: EQ-01699-01 DEC3000 OVMS AXP MUP 01 CD-ROM (AG-Q4B6A-BE) DEC3000 OSF/1 AXP MUP 01 CD-ROM (AG-Q42EA-BE) DEC3000 AXP MUP 01 Firmware Release Notes (AA-Q4B8A-TE) DEC3000 AXP MUP 01 OpenVMS AXP Release Notes (AA-Q4B7A-TE) DEC3000 AXP MUP 01 DEC OSF/1 Release Notes (AA-Q42FA-TE) DEC3000 AXP MUP 01 Cover Letter (AV-Q4B9A-TE) DEC3000 OpenVMS AXP MUP 01 Cover Letter (AV-Q4M5A-TE) FA-05036-01 FA Document