_ DEC-O-LOG for RC25 _ DOL, RC25-M001, RC25 Master Drives JUN 85 PROBLEM: Rework Summary: 1. The "Sems Hardware" is replaced to improve the subchassis grounding. 2. The Electronic Cover is replaced on the Rackmount Units for FCC Compliance and Signal Integrity. 3. The Bulkhead Mounting LESI Cable) is revised for Signal Integrity and Noise Immunity on all Rackmount variations. IN-PLANT EFFECTIVITY: JAN 85 FIELD EFFECTIVITY: Rework all variations of the RC25 Disk Drives. Replace the "Sems hardware" to improve the subchassis for grounding. Rework all variations of the RC25 Rackmount. Replace the Electronics Module Cover and rework the Bulkhead Mtg. I/O Cable. QUICK CHECK: Lack of Plastic Washers at Sems Hardware or presence of Plastic Module Cover. The DEC on-site labor charge will be the time required to install and test the FCO at the then current hourly rate. FCO KIT ORDERING: EQ-01351-01: FCO, PARTS EQ-01351-02: FCO, PARTS FA-04632-01: FCO only _ DOL, RC25-M002, RC25 Master Drives SEP 85 IN-PLANT EFFECTIVITY: MAR 85 FIELD EFFECTIVITY: Rework the RC25 Master Drives with the following variations: AA, AB, BA, BB, CA, CB, FA, FB. QUICK CHECK: Installed by the factory in RC25Drives Revision "C1" and above. The DEC on-site labor charge will be the time required to install and test the FCO at the then current hourly rate. FCO KIT ORDERING: EQ-01357-01: FCO, PARTS FA-04638-01: FCO only _ DOL, RC25-R003, RC25 Master Drives NOV 85 IN-PLANT EFFECTIVITY: JUL 85 PROBLEM: Drives may show a fault condition or corrupt customer data. FIELD EFFECTIVITY: Rework all RC25 Drives, to comply with Dec Standard 103, Section 5.0 for Electrocstatic Discharge. Rework all variations of RC25 Drives by replacing the Bezel Switch Assembly (P/N 70-2066-01). QUICK CHECK: Black conductive film strips between the lens caps of the Run, Write Protect, along with the metal plating (silver grey color) on the rear of the Bezel Assembly. The DEC on-site labor charge will be the time required to install and test the FCO at the then current hourly rate. FCO KIT ORDERING: EQ-01363-01: FCO, PARTS FA-04644-01: FCO only _ DOL, RC25-R004, RC25 Drive Cable JAN 86 FIELD EFFECTIVITY: Rework all Drives (Rackmount, Table-top, Masters and Slaves) using EQ Kit 01357-02. Rework all Master Rackmount Drives with the new KLESI Cable using EQ Kit 01357-01. PROBLEM: Poor System performance due to excessive soft-error rate when operated in a noisy environment. QUICK CHECK: Corrected in the factory in Drives marked Rev "C1" and higher and/or the internal KLESI will be marked with P/N 17-01150-01. The DEC on-site labor charge will be the time required to install and test the FCO at the then current hourly rate. FCO KIT ORDERING: EQ-01357-01 FCO, Parts EQ-01357-02 FCO, Parts FA-04638-01 FCO only