_ DEC-O-LOG for RF72 _ DOL, RF72-O001, RF72 Disk Drive for VAX 6000, DS5000, VAXft, AUG 91 AUG 91 - PROBLEM: "Command Timeouts" caused by corrupted list pointer for the DSSI Interface Chip and excessive BBR's. 2. Improper reporting of MSCP End Packet Status for "Compare Host Data" command processing block with "Forced Error Flag Set".(V256) 3. Fixes problem with Verify utility reporting "Primary " revectored block as "Non-Primary" and vice versa. (V256) 4. BBR's resulting from marginally good blocks. (V256) 5. ADDA chip diagnostic failing on acceptable devices. (V256) 6. Improved algorithm for read/write test data. (V256) 7."Command Timeouts" problems have been identified by Engineering affecting the VAX 6000, DS 5000 and VAXft sys.(V255) 8. Unacceptably high ECC uncor- rectable errors reported running DRVTST (locas to DUAP) (V255) 9. Intro of Single Crystal Ferrite (SCF) heads requires changes to read-after-write timing. (V255) 10. Possibility of inconsistent Revector Control Table(RTC). (V255) FIELD EFFECTIVITY: This "O" coded FCO should be installed in all RF72 option revision C01, installed in VAX 6000, DS 5000 and VAXft systems. QUICK CHECK: Check Option revision label for "E01", module revision "D02". The RF72 module 54-19091-01 Rev. D02 will have a new ROM in location E-4. The new ROM is identified by DIGITAL P/N 23-015EA-00, module revision E02 will have a new ROM P/N 23-024EA-00. Module check, the "Stat Config" command in PARAMS will display the firmware revision as "Software RFXX V256 built 17-May-1991". Refer to the RF72 Users Guide. The DEC on-site labor charge will be the time required to install and test the FCO at the then current hourly rate. FCO KIT ORDERING EQ-01617-04 FA-04950-04