_ DEC-O-LOG for TA78 _ DOL, TA78-I-001, TA78 FUSE FEB 86 PROBLEM: Fuse replacement. NOTE: Recommended for Depot installation only. QUICK CHECK: Second fuse holder mounted in power pack contains F9 thru F14. The DEC on-site labor charge will be the time required to install and test the FCO at the current hourly rate. FCO KIT ORDERING: EQ-01395-01 FCO, PARTS FA-04676-01 FCO only _ DOL, TA78-I002, TA78 CARTRIDGE FEB 86 PROBLEM: None QUICK CHECK: Presence of an external seal placed around the lower Cartridge Restraint Air Inlet Hole. The DEC on-site labor charge will be the time required to install and test the FCO at the current hourly rate. FCO KIT ORDERING: EQ-01399-01 FCO, PARTS FA-04684-01 FCO only _ DOL, TA78-I003, TAPE DRIVE OCT 86 PROBLEM: 1. Data Security Erase (DSE) hangs after TS78 goes available. 2. Read Reverse Retry fails. 3. Initilization of blank tapes fails. FIELD EFFECTIVITY: Rework all TA78's not at REV 4. QUICK CHECK: Issue a "SHOW ROMS" at the ASCII port. ROMS 0 through 4 should be at REV 4. FCO KIT ORDERING: EQ-01419-01 FCO, PARTS FA-04704-01 FCO only _ DOL, TA78-I004, Tape Drive, APR 87 PROBLEM: Excessive soft errors while writing tapes in GCR, and the inability to read tapes written on another tape drive. FIELD EFFECTIVITY: All TA78s not at Rev "H" which do not have this FCO installed and experiencing problems with GCR Write, tape interchangeability and other errors. This FCO implements the following ECOs: M8950-SH009, M8950-SH010, TU78-SH034, TU78-SH036, TU78-SH037. QUICK CHECK: Label on the inside of the front door, and the Preamp module has a shield. This revised FCO supersedes Rev. B released 30 July 1987. It has been revised to correct errors in the text on pages 3, 4, 11, 12, 15, 16, 17. FCO KIT ORDERING: EQ-01455-01 FCO, PARTS FA-04741-01 FCO only