_ DEC-O-LOG for UDA50 _ DOL, UDA50-R0005, UNIBUS Disk Adapter AUG 84 PROBLEM: UDA50's may detect "INTERRUPT TIMEOUT', and the VMS may "hang" for the 5-10 seconds on the VAX-11/750's with CI750 or DR750's (also possible on other configurations). This is due to inefficient "INTERRUPT' handling by the UBI/L0004 (or DW750/L0010) and an insufficient "INTERRUPT TIMEOUT' period in the UDA50. The ERRORLOG message reported will be "RING READ PARITY ERROR/TIMEOUT". CORRECTION: Change the Unibus Disk Adapter, as well as all the supporting Documentation from the Shielded to the Unshielded SDI Cable. IN-PLANT EFFECTIVITY: NOV 84 FIELD EFFECTIVITY: Applicable ONLY to UDA50's installed on the VAX-11/750 Systems. Retrofit UDA50's installed on the VAX 11/750 if the CI750 or a DR750 is present, or if problem symptoms are evident, to the following minimum revision: M7485-YA (Microprocessor) - Revision "H1". Retrofit spares stock to the above minimum level. QUICK CHECK: Check the M7485-YA module for the presence of PROM (23-184F4) in location E16. The DEC on-site labor charge will be the time required to install and test the FCO at the then current hourly rate. FCO KIT ORDERING: EQ-01239-01: FCO, PARTS EQ-01239-02: FCO, PARTS FA-04509-01: FCO only